Version
0.2
1
This
Z
‐
Wave
product
will
be
used
as
routing
slave.
Slave
nodes
are
nodes
in
a
Z
‐
Wave
network
that
receive
commands
and
perform
actions
based
on
the
command.
This
device
will
always
be
in
sleep
mode
because
it
works
on
batteries.
In
sleep
mode
the
device
is
not
active
listening,
the
device
will
wake
up
according
to
the
wakeup
command
class.
Include
Initiator
The
include
initiator
is
used
when
Primary
and
Inclusion
Controllers
include
nodes
into
the
network.
When
both
the
include
initiator
have
been
activated
simultaneously
the
new
node
will
be
included
to
the
network
(if
the
node
was
not
included
previously).
Exclude
Initiator
The
exclude
initiator
is
used
by
Primary
Controllers
to
exclude
nodes
from
the
network.
When
the
exclude
initiator
and
a
slave
initiator
are
activated
simultaneously,
it
will
result
in
the
slave
being
excluded
from
the
network
(and
reset
to
Node
ID
zero).
Even
if
the
slave
was
not
part
of
the
network
it
will
still
be
reset
by
this
action.
Z
‐
Wave
compatibility
Because
this
is
a
Z
‐
Wave
device,
it
means
it
can
co
‐
operate
with
other
Z
‐
Wave
devices
of
other
manufacturers.
It
can
co
‐
exist
in
a
Z
‐
Wave
network
existing
with
product
from
other
manufacturers.
Hops
&
Retries
The
Z
‐
Wave
range
has
a
range
of
up
to
30
meters
in
line
of
sight.
This
signal
is
not
limited
to
the
30
meter
range
due
to
routing
the
Z
‐
Wave
message
to
other
nodes
in
the
network.
This
way
the
range
of
the
Z
‐
Wave
network
can
be
expanded
to
150
meters
indoors
(limit
of
4
hops).
class:
0x20
COMMAND_CLASS_BASIC
When
a
door
is
opened
a
basic
set
frame
with
the
value
255
is
sent
to
the
associated
nodes.
When
a
door
is
closed
a
basic
set
frame
with
the
value
0
is
sent
to
the
associated
nodes.
This
is
the
controlling
role
of
the
basic
command
class.
The
supporting
role
of
the
basic
command
class
is
mapped
to
the
sensor
binary
command
class.
class:
0x25
COMMAND_CLASS_SENSOR_BINARY
The
Sensor
Binary
Command
Class
can
be
used
to
check
the
status
of
the
DoorSensor
(open
or
closed).
Where
“255”
is
open,
and
“0”
is
closed.
class:
0x86
COMMAND_CLASS_VERSION
This
Command
Class
is
used
to
obtain
information
about
the
DoorSensor
.
The
Z
‐
Wave
library
type,
the
Z
‐
Wave
protocol
version
and
the
application
version
will
be
reported.
class:
0x72
COMMAND_CLASS_MANUFACTURER_SPECIFIC
This
will
report
information
about
the
manufacturer.
This
product
will
contain
the
manufacturer
ID
of
Wintop
.
Manufacturer
ID
of
Wintop
is
0x
97
,
th
e
ID
of this product is
0x
82
.
class:
0x70
COMMAND_CLASS_CONFIGURATION
Configure
parameters:
0.
not
used
1.
Set
to
default
Description:
Set
all
config
values
to
default
values
(factory
settings).
Содержание iDoorSensor
Страница 8: ......