Q

:

 

I

 

can’t

 

have

 

my

 

DoorSensor

 

included

 

into

 

my

 

Z

Wave

 

network,

 

what

 

am

 

I

 

doing

 

wrong?

 

A

:

 

1

.

 

Is

 

the

 

controller

 

ready

 

to

 

include

 

any

 

device

 

into

 

the

 

Z

Wave

 

network?

 

If

 

the

 

controller

 

is

 

not

 

in

  

 

Include

 

or

 

exclude

 

mode,

 

the

 

DoorSensor

 

will

 

not

 

be

 

included

 

or

 

excluded.

 

 

2

.

 

The

 

DoorSensor

 

is

 

already

 

included

 

in

 

a

 

Z

Wave

 

network.

 

Exclude

 

the

 

DoorSensor

 

and

  

 

Try

 

to

 

include

 

it

 

again.

 

 

Q

:

 

Why

 

doesn’t

 

the

 

DoorSensor

 

detect

 

if

 

the

 

door

 

is

 

open

 

or

 

closed?

 

A

:

 

1

.

 

The

 

DoorSensor

 

isn’t

 

included

 

in

 

a

 

Z

Wave

 

network.

 

Include

 

it

 

and

 

try

 

it

 

again.

 

 

2

.

 

Make

 

sure

 

the

 

Tamper

 

switch

 

is

 

mounted

 

correctly.

 

 

3.

 

The

 

magnet

 

contact

 

is

 

not

 

mounted

 

close

 

enough

 

or

 

on

 

the

 

wrong

 

side

 

of

 

the

 

device.

 

 

Q:

 

I

 

have

 

configured

 

a

 

value

 

but

 

when

 

I

 

request

 

it,

 

it

 

is

 

not

 

changed?

 

A:

 

It

 

is

 

mandatory

 

that

 

the

 

correct

 

size

 

is

 

used

 

while

 

configure

 

a

 

parameter;

 

go

 

to

 

the

 

documentation

 

about

 

the

 

configuration

 

command

 

class

 

to

 

check

 

if

 

the

 

right

 

size

 

is

 

used

 

during

 

configuration.

 

If

 

the

 

wrong

 

size

 

is

 

used

 

the

 

frame

 

is

 

ignored

 

totally.

  

 

Q:

 

I

 

have

 

configured

 

a

 

new

 

value

 

and

 

when

 

I

 

request

 

it

 

the

 

correct

 

value

 

is

 

returned

 

but

 

the

 

behavior

 

is

 

still

 

the

 

same?

 

A:

 

Some

 

configuration

 

parameters

 

have

 

limits

 

of

 

what

 

they

 

can

 

do,

 

go

 

to

 

the

 

documentation

 

about

 

configuration

 

to

 

check

 

if

 

the

 

value

 

of

 

the

 

configured

 

parameter

 

is

 

out

 

off

 

limit.

 

 
 

Содержание iDoorSensor

Страница 1: ... successful 7 iDoorSensor is now ready to use 8 Remove the back cover of the magnet and repeat step 2 and 4 with the magnet for mounting it Include or exclude in Z Wave network 1 Make sure your Z Wave controller is in the right operation mode include or exclude 2 When the iDoorSensor is mounted remove it from the back cover as explained in step one of the Mounting instructions 3 Press and hold the...

Страница 2: ...SIC_TYPE_ROUTING_SLAVE Generic type GENERIC_TYPE_SENSOR_BINARY Specific type SPECIFIC_TYPE_NOT_USED Listening False Z Wave Lib 4 51 class 0x30 COMMAND_CLASS_SENSOR_BINARY class 0x70 COMMAND_CLASS_CONFIGURATION class 0x71 COMMAND_CLASS_ALARM class 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC class 0x80 COMMAND_CLASS_BATTERY class 0x84 COMMAND_CLASS_WAKE_UP class 0x85 COMMAND_CLASS_ASSOCIATION class 0x8...

Страница 3: ...ps Retries The Z Wave range has a range of up to 30 meters in line of sight This signal is not limited to the 30 meter range due to routing the Z Wave message to other nodes in the network This way the range of the Z Wave network can be expanded to 150 meters indoors limit of 4 hops class 0x20 COMMAND_CLASS_BASIC When a door is opened a basic set frame with the value 255 is sent to the associated ...

Страница 4: ... mode Mode 3 Z Wave chip is always on to request e g version or manufacturer id If any mode other then 3 that value will be reported after a get but will be handled in SW as mode 1 Param2 3 not used 6 The temperature offset Description A offset for the temperature Default 0x00 Size 2 bytes Param1 2 A signed integer to determine the offset off the temperature Param3 4 not used if a size is other th...

Страница 5: ... will go into sleep mode again The wake up interval can be set using the WAKE_UP_INTERVAL_SET command The default value is 0x1C20 7200 sec 2 hour The default node is 0xFF 255 broadcast It is possible to send a wake up notification on user interaction To do this press and hold the tamper switch for 8 seconds When the wake up time is set to 0 a wake up notification is never send periodically only on...

Страница 6: ...Even when a configuration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET Parameter 0x...

Страница 7: ...try it again 2 Make sure the Tamper switch is mounted correctly 3 The magnet contact is not mounted close enough or on the wrong side of the device Q I have configured a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during conf...

Страница 8: ......

Отзывы: