8
6 Troubleshooting
and
remedy
Warning
Repairs to the refrigeration cycle may only be carried out by expe-
rienced refrigeration technicians. Improper repairs may cause sig-
nificant danger for the user, for which Winterhalter is not liable.
IMPORTANT
You may only test the heat pump if the minimum tank level
(dry running protection) is adhered to and the cover is mount-
ed on the lamella heat exchanger. This is the only way to en-
sure air flow.
6.1 Water-related
safety
To ensure fault-free operation, it is important that parameter P630 is set in
accordance with the installed water safety device.
Access the Service Menu and check whether the parameter is set correctly
(for details see PT Series service instructions):
‒
For machines with backflow restrictor type “air gap” (30000127): 50 °C
‒
For machines with backflow restrictor type “BPD” (30000128): 70 °C
6.2 Overview
of
the
troubleshooting diagram
Error Description
Page
1
Heat pump will not start up although tank temperature is
below rated temperature
9
2
Heat pump is working, but generating loud noises
10+11
3
Heat pump is working, but tank temperature cannot reach
the rated temperature
12
4
Error 56 – Heat pump safety circuit
13-15
5
Error 57 – No increase in temperature in the intermediate
circuit (I22) while compressor is active
16
6
Error 58 – Temperature sensor on plate heat exchanger
(I22) defective
17
7
Error 70 – More than ten heat pump cycles of operation
per hour
18
1A, 1B, 1C, … = error code; enter in error log