6. Installation and connection
12
2. Choosing a proper model
For energy-saving and convenience purpose, please choose proper volume of a water tank, the
selection case is below:
80-100L is proper for 1 - 3 users.
3.
Storage and transportation
Generally, it's better to use a container to transport hot water heat pumps and store them in a
suitable and dry place. To short distance carrying, please be careful and the maximum
inclination is no more than 60°.During transportation and storage, the ambient temp is better from
0°C -43°C.
Transported by forklift
When using forklift to carry the unit which must have a pallet, the operator should try best to
keep the height of forklift at a lowest level. Because the top part is heavier ,the operator needs
to take measures to prevent its overturn. To avoid any damages, the unit must stand on a flat
place.
Transport for installation
When transporting for installation, the bottom of unit needs to be added with pallet and use
a rope or belt to fix it well. By this manual carrying or forklift transportation, the inclination is no
more than 60°as the following picture shows. If the inclination unavoidably exceeds 60°,the unit
must be kept at vertical status for at least 1 hour and then can be started for testing or
running.
Notice: The selection of a water tank is only a reference, please choose a
proper. one according to local weather and users consuming habit.
Notice Prevent bottom up
Содержание WSW1-80L-WM