SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
10-6
3. Visually inspect the vehicle undercarriage for
any problems.
4. See the Leveling System Operation Guide
supplied in your InfoCase for troubleshooting
instructions or operating the Leveling System
if jacks fail to retract or any other functions
fail.
Further Information
See the manufacturer’s operation guide
provided in your InfoCase for complete operating
instructions, safety precautions, and
troubleshooting tips.
CHECKING HYDRAULIC OIL
LEVEL
See the Leveling System Operation Guide
provided in your InfoCase for complete
maintenance instructions and information.
All maintenance should be done as part of the
normal servicing of the motorhome.
The hydraulic oil level should be checked
when the vehicle is first purchased and after any
extended storage. During regular vehicle use the
hydraulic fluid level should be checked once a
month. If an oil leak develops, the hydraulic oil
level needs to be checked frequently until repairs
can be completed.
The hydraulic pump is located inside
passenger side compartment front of the entrance
door (Model 34T) or beneath the entrance step
(Models 36H, 38F, 38W, and 38D). Lift step
cover and remove storage bin (if equipped) to
access.
NOTE: Leveling jacks must be in the retracted
(UP) position to get an accurate oil level.
The hydraulic oil level is checked visually by
inspecting the hydraulic oil reservoir. Always
keep the hydraulic oil level full (to the lip of the
breather cap).
NOTE: Always clean away any dirt and debris
from the top of the reservoir before
removing the breather cap to avoid entry
of debris and contamination of hydraulic
oil in the reservoir, which could lead to
pump failure or other problems.
NOTE: Only fill the hydraulic reservoir with the
jacks in the retracted (UP) position.
Adding fluid with the jacks in any other
position will cause fluid to leak through
the breather/fill cap.
Hydraulic Oil Reservoir
(Located inside passenger side
compartment front of the entrance door)
-Typical View
Breather/Fill Cap
Model 34T
Hydraulic Oil Reservoir
(Located below entrance step)
-Typical View
Breather/Fill Cap
Model 36H, 38F, 38W, and 38D