SECTION 6
ELECTRICAL SYSTEMS
6-8
Stopping The Generator
1. Shut off electrical equipment to remove load.
Allow generator to run for 3 to 5 minutes to
cool down.
2. Press the generator switch into the OFF posi-
tion and hold until the generator comes to a
complete halt.
Generator Hourmeter
This meter is located on the monitor panel. It
registers the total number of hours that the gen-
erator has been operated. Refer to the hourmeter
to determine when periodic maintenance is due
and to record services which have been per-
formed.
NOTE: It is normal for the hourmeter to make a
periodic “ticking” sound while the gen-
erator is running.
OPERATION WARNINGS AND
CAUTIONS
1.
Do not
simultaneously operate the generator
engine and a ventilator which could draw
exhaust gases into the vehicle.
2.
Do not
open windows or ventilators on the
end or side of the vehicle where exhaust pipe
of the generator is located.
3.
Park the vehicle
so that the wind will carry
the exhaust away from the vehicle. Also,
note the position of other vehicles to be sure
their exhaust will not enter your vehicle.
4.
Do not
operate the generator engine when
parked if vegetation, snow, buildings, vehi-
cles, or any other object can deflect the
exhaust under or into the vehicle.
Check auxiliary generator oil level frequently
during periods of use. Refer to the generator
manufacturer’s information in your Owners
InfoCase for specific recommendations.
GENERATOR SLIDE OUT SERVICE
TRAY:
The generator service tray can be
extended and retracted by a power slideout
mechanism.
Approximate Power Requirements of
Common Appliances
Appliance or Tool
Approximate Power
Consumption
(Watts/Amps)
Vacuum cleaner
Coffee Maker
Hair dryer
Electric clothes iron
Electric blanket
Television
Electric drill
Air conditioner
Microwave Oven
200-500W/1.7-4.3A
550-700W/4.8-6.1A
800-1500W/7.0-13.0A
500-1200W/4.3-10.4A
50-200W/0.4-1.7A
80-100W/0.7A
250-750W/2.2-6.5A
1400-2000W/13-19A
700-1500W/6.0-13.0A
The exhaust of all internal combus-
tion engines contains carbon monox-
ide (CO). This poisonous gas is
colorless, odorless, tasteless, and
lighter than air. The exhaust systems
of both your motor home engine and
your generator engine have been
installed with your safety in mind.
However, certain precautions must be
taken when using them to protect
yourself from conditions beyond the
control of the manufacturer.
Never check generator oil level while
generator engine is running.
WARNING
WARNING
Содержание 2004 Ultimate Freedom
Страница 4: ......
Страница 14: ......
Страница 72: ......
Страница 86: ......
Страница 96: ......
Страница 128: ......
Страница 148: ......
Страница 150: ...MAINTENANCE RECORD Date Odometer Mileage Description of Service Cost...
Страница 151: ...FUEL OIL RECORD Date Odometer Mileage Fuel Gal Oil Qts MPG Cost Date Odometer Mileage Fuel Gals Oil Qts MPG Cost...
Страница 152: ...FUEL OIL RECORD Date Odometer Mileage Fuel Gal Oil Qts MPG Cost Date Odometer Mileage Fuel Gals Oil Qts MPG Cost...