background image

winkhaus.de

blueMatic EAV

Automatic locking system with motorised opening function 
(12 V DC)

Installation, Operating and Maintenance Instructions  
02/2021

Содержание blueMatic EAV

Страница 1: ...winkhaus de blueMatic EAV Automatic locking system with motorised opening function 12 V DC Installation Operating and Maintenance Instructions 02 2021...

Страница 2: ...status of the development and manufacture of this product For the purpose of customer satisfaction and operational reliability of the blueMatic EAV Automatic locking system with motorised opening fun...

Страница 3: ...s P 11 2 Product description Automatic locking system autoLock AV3 P 16 Motor housing P 25 Keep rail Extension keep set Single keeps P 26 Center keep FRA AV P 27 Magnetic trigger for center keep FRA A...

Страница 4: ...P 47 3 5 2 Wireless receiver separate P 51 3 6 Non Winkhaus access control system ACS P 53 3 6 1 Non Winkhaus access control system ACS general frame and sash side P 53 3 6 2 Non Winkhaus access cont...

Страница 5: ...specifications 7 1 Motor housing EAV3 P 81 7 2 Power supply mounting on DIN rail P 81 7 3 Frame power supply P 81 7 4 Antenna Reader P 82 7 5 Wireless remote control P 82 7 6 Cable transition T K T1 F...

Страница 6: ...EAV Automatic locking system with motorised opening function and the Winkhaus components recommended are suitable for the following areas of application relative air humidity of max 95 ambient air te...

Страница 7: ...function and the installation specifications not used in any other way than described maintained and cared for at regular intervals as instructed and or defined sliding places oil at least 1 x annual...

Страница 8: ...door is drilled through in the area of the lock housings or of the lock rod once the lock has been installed the dead bolt projection or other locking components are employed contrary to their intende...

Страница 9: ...tions 1 EN Aug Winkhaus GmbH Co KG Berkeser Stra e 6 98617 Meiningen T 49 369 3950 0 www winkhaus de Subject to technical changes Flags are used to identify important information in this operating man...

Страница 10: ...of the product For security reasons the lock has been designed to be used in conjunction with genuine Winkhaus parts Using other parts may adversely affect the given properties of the security lock It...

Страница 11: ...system with motorised opening function Handle Door handle Grt Set SB FRA Center keep latch dead bolt adjustment plate M2 with 2 hooks MV means upper adjustment UMV means lower adjustment RS DIN right...

Страница 12: ...cal changes 2 Product description The blueMatic EAV Automatic locking system with motorised opening function is a state of the art locking unit for securing and locking entry doors in a contact free m...

Страница 13: ...ns 2 EN Aug Winkhaus GmbH Co KG Berkeser Stra e 6 98617 Meiningen T 49 369 3950 0 www winkhaus de Subject to technical changes Figure 2 2 blueMatic EAV with accessories and frame power supply T NETZTE...

Страница 14: ...SL Single keeps T SB X X Center keep T SB FRA AV X X Magnetic trigger X X Daytime latch TaFa X Cable transition X Cable transition sash part T K T1 FT e g T K T1 FT 2M 3 5M 4 5M Cable at the sash side...

Страница 15: ...y X Figure 2 1 Power supply T HT NETZTEIL 12 V DC 2A mounting on DIN rail Figure 2 2 Frame power supply T NETZTEILRAHM 12 V DC 1 5 A 2A 2S optional including cable for connection of ex ternal access c...

Страница 16: ...k AV3 from Winkhaus is an auto matic multipoint locking system with indepen dently acting hooks for claw action and sealing elements for a dynamic contact pressure This is prepared for installation of...

Страница 17: ...3 5010014 T AV3 F1660 L79 50 A9 94 8 KABA M2 RS LS MC 5016748 5016749 T AV3 F1660 L79 50 A9 92 10 M2 RS LS MC 5007837 5007836 T AV3 F1660 L79 55 A9 92 8 M2 RS LS MC 5005474 5005473 T AV3 F1660 L79 55...

Страница 18: ...0 A9 92 10 M2 RS LS MC 5041992 5041993 T AV3 F1669 L79 35 A9 92 8 M2 RS LS MC 5007898 5007897 T AV3 F1669 L79 40 A9 92 8 M2 RS LS MC 5007900 5007899 T AV3 F1669 L79 45 A9 92 8 M2 RS LS MC 5006136 5006...

Страница 19: ...0 L79 55 A9 92 8 M2 RS LS GR 5008988 5008989 T AV3 F2060 L79 55 A9 92 10 M2 RS LS MC 5014869 5014868 T AV3 F2060 L79 60 A9 92 10 M2 RS LS MC 5006103 5006101 T AV3 F2060 L79 65 A9 92 8 M2 RS LS MC 5014...

Страница 20: ...2 8 M2 RS LS MC 5008189 5008188 T AV3 F2070 L79 45 A9 92 8 M2 RS LS MC 5008185 5008184 T AV3 F2070 L79 55 A9 92 8 M2 RS LS MC 5008187 5008186 T AV3 F2070 L79 65 A9 94 8 KABA M2 RS LS MC 5024235 502423...

Страница 21: ...9 35 A9 92 8 M2 RS LS MC 5008021 5008020 T AV3 F2469 L79 35 A9 92 8 M2 RS LS GR 5008019 5008018 T AV3 F2469 L79 40 A9 92 8 M2 RS LS GR 5077061 5077062 T AV3 F2469 L79 45 A9 92 8 M2 RS LS MC 5014465 50...

Страница 22: ...92 8 M2 RS LS GR 5023168 5023169 T AV3 U2462 L79 40 A9 92 8 M2 RS LS MC 5053117 5053118 T AV3 U2462 L79 45 A9 92 8 M2 RS LS MC 5008191 5008190 T AV3 U2462 L79 45 A9 94 8 KABA M2 RS LS MC 5009975 5009...

Страница 23: ...C 5013204 T AV3 U2471 L79 35 A9 92 8 M2 RS LS MC 5008071 5008070 T AV3 U2471 L79 35 A9 92 8 M2 RS LS GR 5006204 5006203 T AV3 U2471 L79 45 A9 92 8 M2 RS LS MC 5014884 5014885 T AV3 U2471 L79 45 A9 92...

Страница 24: ...50 A9 92 8 M2 RS LS MC 5063958 5063959 T AV3OR F2060 L79 55 A9 92 8 M2 RS LS MC 5041576 5041577 T AV3OR F2060 L79 65 A9 92 8 M2 RS LS MC 5041594 5041595 T AV3OR F2062 L79 65 A9 92 8 M2 RS LS MC 50759...

Страница 25: ...9 369 3950 0 www winkhaus de Subject to technical changes Motor housing Motor housing for powered unlocking with integrated control unit but without cable for transponder or wireless remote control an...

Страница 26: ...e keeps Select the corresponding standard frame parts in the current program manual Keep rail exten sion keep set single keeps T PLB HOLZ KT 4934769 Program overview keep Timber group 2 T PLB KUNSTSTO...

Страница 27: ...retrofitted in center keeps FRA AV with magnet hole Center keep FRA AV Center keep for latch and deadbolt for retro fitting of magnetic trigger and daytime latch TAFA Designed for use with PVCu Alumin...

Страница 28: ...ARK LS 5015108 Daytime latch with lower contact pressure 10 9 can be used with standard T SB FRA or FAB1 not with FAB T TAGESFALLE 10 9 TAFA FA RS 5006563 T TAGESFALLE 10 9 TAFA FA LS 5006564 T TAGESF...

Страница 29: ...transition Plug in and concealed cable transition Inserted by plug in function with retaining screws 3 x 20 mm Sash part with spring sleeve in different versions see table Order frame part separately...

Страница 30: ...K EAV 1 5 M Y 0 5 M 5085768 Sash part with 1 5 m cable 5 pole plug for connection with Y cable Y Kabel INSIDE EAV 0 5 m e g for timber entrance doors e g Fingerprint IDENCOM BioKey INSIDE or ekey home...

Страница 31: ...Part Description see also Figure 3 2 Part no T ABDECKBLECH K T1 FT F16 R8 MC 4990670 Cover plate for sash flat faceplate 16 mm round ends R8 length 126 mm suitable for PVCu timber if necessary T ABDE...

Страница 32: ...c EAV 12 V DC direct current stabilized min 1 5 A continuous current for further external loads e g intercom LED lighting video systems etc separate or designed power supplies must be used Notice If n...

Страница 33: ...ubject to technical changes Frame power supply optional The Winkhaus frame power supply is a switching power supply single phase primary pulsed installation current supply high pulse load capacity sho...

Страница 34: ...G Berkeser Stra e 6 98617 Meiningen T 49 369 3950 0 www winkhaus de Subject to technical changes Access control systems From the outside the door is opened via the access control system transponder wi...

Страница 35: ...erating and Maintenance Instructions 2 EN Aug Winkhaus GmbH Co KG Berkeser Stra e 6 98617 Meiningen T 49 369 3950 0 www winkhaus de Subject to technical changes 1 wireless receiver to be inserted in t...

Страница 36: ...m and additionally the motor housing as shown in the following diagrams 3 1 Routing details Figure 3 1 1 Dimensions for blueMatic EAV D Backset G Handle position L Length croppable nT low doors hT hig...

Страница 37: ...en T 49 369 3950 0 www winkhaus de Subject to technical changes blueMatic EAV Installation Operating and Maintenance Instructions Description Installation situation Situation hook Situation magnetic t...

Страница 38: ...ash frame part Recommendation It is recommended always that the cover plate depends on the faceplate and the material type of timber PVCu plastic or aluminum conceals the routing for the required cabl...

Страница 39: ...through the door frame including cable reserves in frame use T ABDECKUNG K T1 RT R8 Fasten the frame part 2 with the fitting screw 3 x 20 mm Sash part with cover plate Figure 3 2 1 Mill slotted hole m...

Страница 40: ...d Maintenance Instructions Figure 3 2 3 Detail T K T1 FT without cover plate Complete the plug in connection after putting the door on its hinges Fix the sash part with the fitting screw 3 x 20 mm Fig...

Страница 41: ...rating and Maintenance Instructions Cover plate for T K T1 FT Figure 3 2 5 Routing dimensions T K T1 FT RT and cover plate F20 in Timber Figure 3 2 6 Routing dimensions T K T1 FT RT and cover plate F1...

Страница 42: ...f you connect an intercom system take care that the button of this system is designed as a potential free contact External voltage must not be transmitted from the intercom system to the lock 5044744...

Страница 43: ...nnection Open button other button Release signal for swing door opener optional length and cross section specification by the manufacturer of swing door opener 230 V AC to from the motor housing Acces...

Страница 44: ...e transponder signal is processed in the reader control unit This unit has to be installed in a standard flush type box inside the building close to the door 3 4 Access control system transponder set...

Страница 45: ...e 6 98617 Meiningen T 49 369 3950 0 www winkhaus de Subject to technical changes blueMatic EAV Installation Operating and Maintenance Instructions Connect the cable of the antenna fixed in the antenn...

Страница 46: ...and cross section specification by the manufacturer of swing door opener to from the motor housing Antenna cable of 2 x 0 8 mm length of max 40 m e g Connector block via electrical contractor cable of...

Страница 47: ...ibutor To prevent manipulation of the receiver we recommend installing the receiver on the inner side of the door 3 5 Access control system wireless remote control Notice If you use the flush type box...

Страница 48: ...al assignment of the wireless receiver No Terminals wireless receiver 1 Break contact NC is not required 2 Contact C connect with a green wire from the cable transition 3 Make contact NO connect to te...

Страница 49: ...Release signal for swing door opener optional length and cross section specification by the manufacturer of swing door opener to from the motor housing cable of 2 x 0 8 mm length of max 40 m e g Conn...

Страница 50: ...N Aug Winkhaus GmbH Co KG Berkeser Stra e 6 98617 Meiningen T 49 369 3950 0 www winkhaus de Subject to technical changes blueMatic EAV Installation Operating and Maintenance Instructions Figure 3 5 1...

Страница 51: ...ate Separate wireless receiver for additional applications such as garage door control units Installation sequence Remove the cover of the housing Fasten the housing with screws Push in the rubber plu...

Страница 52: ...ated contact is open it closes by activating per remote control 9 10 NC relay K4 non operated contact is close it opens by activating per remote control 11 12 12 V AC DC 11 13 24 V AC DC 14 Antenna 15...

Страница 53: ...l to the access control fingerprint further access controls potential free signal e g Open button intercom should be used for unlocking this is possible via the frame part T K T1 RT KABEL 4 M or frame...

Страница 54: ...t for external poten tial free contact e g unlocking via intercom open button Notice max 40 m extendable min 0 8 mm2 Description Part no Sash part cable transition T K T1 FT EKEY MICRO PLUS 1 5M 50576...

Страница 55: ...input for external potential free contact e g unlocking via inter com open button Notice max 40 m extendable min 0 8 mm2 Description Part no Sash part cable transition T K T1 FT EKEY MICRO PLUS 1 5M...

Страница 56: ...Notice max 40 m extendable min 0 8 mm2 Description Part no Sash part cable transition T K T1 FT EKEY MICRO PLUS 1 5M 5057683 Frame part cable transiti on T K T1 RT Kabel 4M for external power supply...

Страница 57: ...max 40 m extendable min 0 8 mm2 white 12 V DC brown 0 V green external opening signal yellow grey pink unscript 230 V AC Description Part no Sash part cable transition T K T1 FT EKEY MICRO PLUS 1 5M...

Страница 58: ...e fingerprint plug in Screw type terminal Connection to motor housing EAV relay 1 white supply brown supply green switching pulse relay 2 at integra 2 external opening signal Description Part no Set o...

Страница 59: ...type terminal Connection to motor housing EAV relay 1 white supply brown supply green switching pulse 230 V AC Description Part no Set of cable transition T SET K T1 FT INTEG EAV 1 3M including connec...

Страница 60: ...tor housing swing door green white input for external potential free contact e g unlocking via intercom open button Notice max 40 m extendable min 0 8 mm2 Description Part no Sash part cable transitio...

Страница 61: ...housing swing door green white input for external potential free contact e g unlocking via intercom open button Notice max 40 m extendable min 0 8 mm2 white 12 V DC brown 0 V green external opening s...

Страница 62: ...h part cable transition to the radio receiver ENTRAsys RX plug in Connection from radio receiver ENTRAsys RX to the motor housing EAV plug in Connection from radio receiver ENTRAsys RX to the fingerpr...

Страница 63: ...Asys RX Notice included in the set Frame part cable transition T K T1 RT Kabel 4M for external power supply mounting on DIN rail 5040503 Motor housing EAV for re trofitting mechanical locking system A...

Страница 64: ...e white 12 V DC brown 0 V green yellow grey pink external opening signal Notice In the combination of the SOMMER ENTRAsys FD fingerprint with Winkhaus blueMatic EAV MANDATORY do not change the specifi...

Страница 65: ...transition T K T1 RT KABEL 0 6M RNT for frame power supply 5040504 Extension cable T LB VERL KABEL 0 25M RNT ZU K T1 5066122 Motor housing EAV for re trofitting mechanical locking system AV3 standard...

Страница 66: ...sp 2 When using a blueMatic EAV with control of the swing door drive an additional cable transition and frame part must be used T K T1 FT 3 5M Part no 5040505 T K T1 RT KABEL 4 M Part no 5040503 Inste...

Страница 67: ...l protection is provided by manual locking one rotation of the key 1 x 360 causes the deadbolt in the main lock housing to be thrown 4 1 blueMatic EAV Daytime function Temporary unlock of the door by...

Страница 68: ...established contact free The transponder data is transmitted to the reader unit via the antenna An acoustic signal at the reader unit will acknowledge the data transfer The reader checks whether this...

Страница 69: ...card red These cards are programmed to this reader control unit 4 2 2 Programming Teach in mode Programming card Set teach in mode teach transponder chip Action Acoustic Signal Result Pass the progra...

Страница 70: ...delete all card all the transponder chips stored in the system will be deleted The action of deleting all transponder chips is irrevocable once the process has been completed You have to teach up to 2...

Страница 71: ...mmed button A To trigger a signal press the A button of a progammed remote control The red LED will turn on and the door will be unlocked 4 3 blueMatic EAV with wireless remote control 4 3 1 Operation...

Страница 72: ...nnnn continuous signal is briefly interrupted pressed button s is are authorised If no remote control has been taught e g after delete all function it would apply to all remote control The teach in mo...

Страница 73: ...ul taneously n short Teach in mode started 2 Press A button of the same remote control nnnnnnnnnn continuous signal as long as delete mode is active Teach in mode active 3 Press buttons A and B of a p...

Страница 74: ...lled to capacity max 85 buttons if the teach in button of a new wireless remote control is used and both LED displays of the receiver flash simultaneously Teaching wireless remote controls directly vi...

Страница 75: ...ditional applications specified by the respective application For this purpose press the P1 button of the receiver until the green LED lights up Release the button again Press the P1 button once more...

Страница 76: ...the wireless remote control has been programmed Teaching in via the wireless receiver Part no 2142897 Partial deletion Press and hold the P1 button for about 2 seconds When the green LED lights up rel...

Страница 77: ...eck the locking mechanism and smooth operation of the security lock at regular intervals at least once every three months At least once a year more frequently if under a higher stress factor all movea...

Страница 78: ...not suffi cient chapter 3 rework the milling if necessary the door can not be closed the tracer pin is blocked in the center keep the door sash has not been mounted properly at the center keep change...

Страница 79: ...gap etc Power failure when during a the door is locked the door can be operated mecha nically profile cylinder handle b the door is open lock is unlocked the door is pos sibly not held by the latch t...

Страница 80: ...Does not operate with remote control red LED is not illuminating remote battery dead replace battery in remote control the lock works correctly when the door is open but no longer works after locking...

Страница 81: ...A Output 12 V DC 1 A 2 A f r 2 s Protection rating IP 20 Temperature range 20 C bis 60 C Earthing of the door frame Eyelet screw connection with 4 x 15 mm Dimensions Frame part approx 24 x 260 x 33 mm...

Страница 82: ...mption max 100 mA Voltage 12 V DC 7 5 Wireless remote control Receiver type Superheterodyne Modulation AM ASK Frequency 433 92 MHz Number of code combinations 2 to the power of 64 Rolling Code Frequen...

Страница 83: ...Sensitivity to receive signals 115 dB Input impedance 50 Ohm Maximum memory capacity 85 codes for remote control Power supply 12 24 V AC DC Closed circuit current 15 mA On load current 33 48 mA Numbe...

Страница 84: ...x voltage 48 V DC Max switching current 2 A per connection line wire T SET K T1 FT ZK EAV 3 5 Y 0 5 M alternatively T SET K T1 FT ZK EAV 1 5 M Y0 5 M Plug n play solution for fingerprint IDENCOM BioKe...

Страница 85: ...ENTRAsys 3 m 3 x 0 25 mm 1st Cable end with plug for motor housing EAV 2nd Cable end with plug for radio receiver ENTRAsys RX Max voltage 48 V DC Max switching current 2 A per connection line wire Cab...

Страница 86: ...EAV BL 2410265 form key fob color blue T HT FUNK HANDSENDER F01 4 KANAL SL SW 5003295 4 channel wireless remote control separate as an extension to set T HT FUNK FERNB F02 ANTHR SET 3 1 2410273 color...

Страница 87: ...STK RNT T ABDECKUNG K T1 RT R8 RAL 7035 5040517 Cover Strip T K T1 RT R8 separate serves to cover the profile hole on the frame side when using the frame part T K T1 RT KABEL 0 6M RNT Cover Strip T LB...

Страница 88: ...0 2 T EAV3 35 85 mm 92 mm PZ 94 mm RZ Flat 16 mm U 22 x 5 mm 2 S 5 C 0 G 3 0 2 T AV2B 35 65 mm 92 mm PZ 94 mm RZ Flat 16 mm U 22 x 5 mm 2 S 5 C 0 G 3 0 2 9 Classification Declaration of performance Ac...

Страница 89: ...ingen Drei igacker Deutschland 5 Name and contact information of the authorised person if applicable who is commissioned with the tasks in accordance with Article 12 paragraph 2 CPR N A 6 Systems or s...

Страница 90: ...rdance with the European directive 2012 19 EU at a municipal collection centre for electronic waste or via a specialist company Notice The packaging must be recycled separately in accordance with the...

Страница 91: ......

Страница 92: ...Winkhaus GmbH Co KG Berkeser Stra e 6 D 98617 Meiningen T 49 3693 950 0 F 49 3693 950 134 winkhaus de tuerverriegelung winkhaus de T SB February 2021 Print No 5044744 EN All rights and changes reserv...