Classification
Spec
Remark
Model
WDH 751
Power Supply
AC 115V/60(Hz)
Moisture Capacity 50 Pints
24-Hour Period
Control Type
Electronic
Refrigerant
R-22/9.52 oz.
270g
Humidity
Humidity Setting: 35%-70%
5% Increments
Timed Shut-off
Setting Range: 1Hr-12Hr
1 Hour Increments
Fan Motor Speed
2 Stages
High/Low
Dimensions
15.75x26.30x13.31 in
400x668x338mm
Net Weight
41.9 lbs
19Kg
Operating Temp.
36°F-99°F
Drain Pump
12V DC
Pump Drain Hose .25 in x 18 ft
6.35x5,486mm
Error
Code
Error Type
Possible Causes Corrective Actions
E3
Pump Drain
1. Improper
bucket
installation.
2. Blockage to
drain hose
system.
3. Back flow of
water through
pump drain
hose.
4. Improper pump
drain hose
installation.
5. Faulty drain
pump.
1. Unplug the dehumidifier.
2. Remove the bucket.
3. Check to make sure that there is nothing
blocking the connection at the base of the
pump or the bucket.
4. Reinstall the bucket, taking care that it is
installed properly.
5. Check to make sure that the pump drain
hose is not crimped or blocked.
6. Check to make sure that the pump drain
hose is not both under water and sitting at
a height above the dehumidifier – this can
cause a “back flow” of water from the hose
to the dehumidifier.
7. Remove and reinstall the pump drain hose,
taking care that the pump drain hose is
installed properly.
8. Plug the dehumidifier in and restart
PRODUCT SPECIFICATIONS
ERROR CODES
10