background image

Classification

Spec

Remark

Model

WDH 751

Power Supply

AC 115V/60(Hz)

Moisture Capacity 50 Pints

24-Hour Period

Control Type

Electronic

Refrigerant

R-22/9.52 oz.

270g

Humidity

Humidity Setting: 35%-70%

5% Increments

 

 

Timed Shut-off

Setting Range: 1Hr-12Hr

1 Hour Increments

Fan Motor Speed

2 Stages

High/Low

Dimensions

15.75x26.30x13.31 in

400x668x338mm

Net Weight

41.9 lbs

19Kg

Operating Temp.

36°F-99°F

Drain Pump

12V DC

Pump Drain Hose .25 in x 18 ft

6.35x5,486mm

Error 

Code

Error Type

Possible Causes Corrective Actions

E3

Pump Drain

1. Improper 

    bucket 

    installation.

2. Blockage to 

    drain hose 

    system.

3. Back flow of 

    water through 

    pump drain 

    hose.

4. Improper pump 

    drain hose 

    installation.

5. Faulty drain 

    pump.

1. Unplug the dehumidifier.

2. Remove the bucket.

3. Check to make sure that there is nothing

    blocking the connection at the base of the

    pump or the bucket.

4. Reinstall the bucket, taking care that it is

    installed properly.

5. Check to make sure that the pump drain

    hose is not crimped or blocked.

6. Check to make sure that the pump drain

    hose is not both under water and sitting at

    a height above the dehumidifier – this can

    cause a “back flow” of water from the hose

    to the dehumidifier. 

7. Remove and reinstall the pump drain hose,

    taking care that the pump drain hose is

    installed properly.

8. Plug the dehumidifier in and restart

PRODUCT SPECIFICATIONS

ERROR CODES