background image

ELECTRICAL REQUIREMENTS

INSTALLING YOUR DEHUMIDIFIER

4

5

OBSERVE ALL LOCAL CODES AND 

ORDINANCES. 

DO NOT, UNDER ANY CIRCUMSTANCES, 

REMOVE THE POWER SUPPLY CORD 

GROUND PRONG. 

ELECTRICAL GROUND IS REQUIRED ON 

THIS APPLIANCE.

A 115-VOLT 60Hz, AC ONLY, 15A 

FUSED AND PROPERLY GROUNDED 

ELECTRICAL SUPPLY IS REQUIRED.

DO NOT USE AN EXTENSION CORD.

CHOOSING THE PROPER LOCATION

Use the dehumidifier:

• in the basement to help prevent moisture 

  damage.
• in the kitchen, laundry room, bathroom, 

  and spa/exercise areas that have exces-

  sive moisture.
• to prevent moisture damage anywhere 

  books or valuables are stored.
• during construction or remodeling to 

  reduce drying time for drywall and paint.

• Install the dehumidifier on a level floor   

  strong enough to support the unit with a 

  full bucket of water.
• For best performance, allow at least 12-

 18 inches of air space on all sides of the 

 unit for good air circulation.
• Keep all outside doors, windows and 

  other openings closed when operating the 

  dehumi

difier.

 Humid outdoor air will add to 

  the unit’s workload.
• For maximum efficiency, install your 

  dehumidifier in an area where the 

  temperature will not fall below 65°F.

RECOMMENDED GROUNDING METHOD

For your personal safety, this appliance 

must be grounded. This appliance has a 

power supply cord with a 3-prong grounded 

plug. To minimize possible shock hazard, 

the cord must be plugged into a matching 

grounded electrical outlet that complies with 

the latest edition of the National Electrical 

Code and all local codes and ordinances.

If a grounded 3-prong electrical outlet is not 

available, it is the personal responsibility 

and obligation of the customer to have one 

installed by a qualified electrician.

ELECTRICAL SHOCK HAZARD

Plug into a grounded 3-prong outlet.

• Do not remove ground prong. 

• Do not use a two-prong adapter. 

• Do not use an extension cord. 

Failure to follow these instructions can result 

in death, fire or electrical shock.

WARNING

 

  

• At temperatures below 65°F, the evapor- 

  ator coils may become covered with frost, 

  reducing the dehumidifier’s performance.
• Leave the dehumidifier in an upright  

  position for 30 minutes before turning on. 

DEFROST OPERATION

The dehumidifier has a built-in defrost 

control that senses frost buildup on the 

evaporator coils.
During defrosting, the compressor will 

automatically turn off; the fan will continue 

running to defrost the coils.

AUTOMATIC SHUT OFF

• When the bucket is full, or when the buck-

  et is not in the proper position, the Bucket 

  Full light goes on and the unit automati-

  cally shuts off.
• The bucket must be replaced in the 

  proper position for the dehumidifier to 

  work. The light will stay on and the dehu-

  midifier will not run if the bucket is not in 

  the proper position.
• The dehumidifier will shut off once the 

  desired humidity setting is reached.

To reduce the risk of fire, electric shock or injury to persons, read the important 

SAFETY INSTRUCTIONS found on page 3 before operating this appliance.

WARNING

KEY FEATURES OF YOUR DEHUMIDIFIER

CONTROL

PANEL

FRONT GRILL 

AIR INLET

FILTER 

GRAVITY HOSE

ATTACHMENT

Power supply cord

 3-prong grounded plug

Grounded 3-prong

electrical outlet

A time delay fuse or time delay circuit 

breaker is recommended. Use a dedicated

circuit serving only this appliance.

CASTER 

HANDLE

GRAVITY

DRAIN

PUMP  DRAIN 

BUCKET

www.sylvane.com  1-800-934-9194

Отзывы: