User Manual of Network Camera
78
other.
Figure 6-49
Configuring Intrusion Area
You can click
Clear
to clear the areas you drawn.
The defense region parameters can be set separately.
3.
Choose the
region
to be configured.
Threshold:
Range [0-10s], the threshold for the time of the object
loitering in the region. If you set the value as 0, alarm is triggered
immediately after the object entering the region.
Sensitivity:
Range [1-100]. The value of the sensitivity defines the size of
the object which can trigger the alarm, when the sensitivity is high, a very
small object can trigger the alarm.
Percentage:
Range [1-100]. Percentage defines the ratio of the in-region
part of the object which can trigger the alarm. For example, when you set
the percentage as 50%, half of the object entering the region will trigger
the alarm.
Arming Schedule is configured to set the time you want the function to be
enabled.
1.
Click
Edit
to set the arming schedule.
2.
Choose to trigger alarm actions as
Notify Surveillance Center
,
Send Email
,
Upload to FTP
and
Trigger Channel
or trigger the
Alarm Output
.
3.
Click
Save
to save the settings.