INSTALLATION

 

AND

 

USER

 

MANUAL

 

2. 

EQUIPMENT 

The air conditioner is composed of 2 separate units, of a thermostat and a wiring box. They must be 
connected by frigorific ducting pipes and electric connections.
The ducting pipes length between both 

2.1. 

Outside unit 

The unit must be installed outside or in a room.
 
If the unit is installed outside: 

-

 

Place the unit in order the air suction and air rejection are not disturbed

-

 

Encourage the installation in open areas and sheltered from the sun

-

 

Be cautious to the noise to the neighborhood

-

 

Raise the unit to prevent from 

 
If the unit is installed in a room : 

-

 

Place the unit in order the air suction and air rejection are not disturbed

-

 

Ensure there is a good ventilation 

-

 

Maximum temperature and non permanent

-

 

Ideal temperature  ≈ 20°C. 

2.2. 

Inside unit 

Install the inside unit only inside the cellar

2.3. 

Thermostat  

The thermostat can be installed either inside or outside the 
If installed outside, take into consideration the length of the temperature probe to be installed into the 
cellar. 
The delivered probe has a length of 1.5m. 
minimal section of 0.5mm2. 

2.4. 

Connection box 

The connection box can be installed too either inside or outside the 
If installed outside, take into consideration the cable length ( 2 m)

2.5. 

Connection drawing 

 

 

 

TAKE INTO CONSIDERAT

 

 
 
 
 
 
 
 
 
 
 

OUTSIDE UNIT  

NO CABLE SUPPLIED 

 

MANUAL

  

WINESP40CAPRO 

 

The air conditioner is composed of 2 separate units, of a thermostat and a wiring box. They must be 
connected by frigorific ducting pipes and electric connections. 
The ducting pipes length between both units 

should not exceed 20m.

 

The unit must be installed outside or in a room. 

Place the unit in order the air suction and air rejection are not disturbed 
Encourage the installation in open areas and sheltered from the sun 
Be cautious to the noise to the neighborhood 

from accumulation of water and snow  

Place the unit in order the air suction and air rejection are not disturbed 
Ensure there is a good ventilation  

and non permanent≤ 40°C 

side the cellar. 

The thermostat can be installed either inside or outside the cellar. 
If installed outside, take into consideration the length of the temperature probe to be installed into the 

The delivered probe has a length of 1.5m. It can be extended by flexible cable isolated to 2 drivers of 

The connection box can be installed too either inside or outside the cellar. 

consideration the cable length ( 2 m) 

 

TAKE INTO CONSIDERATION THE CABLE LENGTHS BETWEEN THE 

CONNECTION BOX AND THE UNITS

 

 
 
 
 
 

 
 
 

THERMOSTAT 

 CABLE LENGTH 2M 

MAIN CONNECTION  

NO CABLE SUPPLIED 

Page 7

 

The air conditioner is composed of 2 separate units, of a thermostat and a wiring box. They must be 

 

 

If installed outside, take into consideration the length of the temperature probe to be installed into the 

can be extended by flexible cable isolated to 2 drivers of 

S BETWEEN THE 

 

INSIDE UNIT  

 CABLE LENGTH 2M 

Содержание SP40CAPRO

Страница 1: ...ment INDICATIONS STATED ON THE NAMEPLATE OF THE UNIT o Model o Serial N o Purchase date MANUAL WINESP40CAPRO Installation and user manual please keep this document carefully SP40CAPRO INDICATIONS STATED ON THE NAMEPLATE OF THE UNIT Guide ref Page 2 user manual 03 2015 ...

Страница 2: ...he outside unit 10 3 3 Installation of the inside unit 11 3 4 Ducting connection 11 3 5 Electric connection 12 3 5 1 Connection of outside unit 12 3 5 2 Connection of inside unit 12 3 5 3 Plugging 12 3 5 4 Wiring drawing 13 3 6 Installation of the water drain system 14 4 PLUGGING THE AIR CONDITIONER WINEMASTER 14 4 1 Connecting the air conditioner 14 4 2 Start up 15 4 2 1 Temperature setting 15 4 ...

Страница 3: ...will bring you great storage conditions and best wines aging for an incomparable pleasure Because the customer is at the heart of all our thoughts we want to support you in your first steps and lead you towards the best use of your air conditioner every day Thus you will find in this manual technical information and practical advice to help you to deal with the essential steps to installation and ...

Страница 4: ...formance is dependant from the outside temperature Therefore the set temperature of 12 C for the cellar cannot be maintained if the outside temperature reaches the 40 C If the thermal safety functions to often there is a risk for the compressor to be damaged In all cases it must be avoid that the outside temperature remains at 40 C this high temperature should be limited to the summer period VENTI...

Страница 5: ...INSTALLATION AND USER MANUAL WINESP40CAPRO Page 6 Technical drawing Outside unit Inside unit Thermostat Wiring box ...

Страница 6: ...MANUAL WINESP40CAPRO The air conditioner is composed of 2 separate units of a thermostat and a wiring box They must be connected by frigorific ducting pipes and electric connections The ducting pipes length between both units should not exceed 20m The unit must be installed outside or in a room Place the unit in order the air suction and air rejection are not disturbed Encourage the installation i...

Страница 7: ...alled By tongue and groove panels or By fused together panels IMPORTANT Avoid heat and humidity intrusion which can alter their regulation View 1 WALL 2 INSULATION MATERIAL 3 GROUND LEVEL 4 FLOOR 5 CEILING 6 INSULATED DOOR IMPORTANT The WINEMASTER warranty is only valid if the insulation is in compliance with the board Insulation selection requirements for the whole cellar walls floor door and cei...

Страница 8: ...al composition is not attacked by the rodents Floor insulation The floor of the cellar must be able to support the shelves and the stored wine Thus it s necessary to choose insulation with adequate compression strength Improve the load capacity of the insulation particularly under the shelve legs by using Complex insulation panels covered by panels of higher load capacity Cover the insulation pane...

Страница 9: ...ITIONER WINEMASTER material for outside unit connection for the connection of wiring box for the cooling connection Screws and tools for fixing the outside unit Installation of the outside unit Brackets installation Trace and drill the holes Unfold the brackets and fi the ing the outside unit Screw the 4 anti Place the air conditioner on the brackets Screw the 4 screw spanner of 10 Page 10 WINEMAS...

Страница 10: ... a resumption of the air supply even partia suction temperature should be the same as the room temperature when the unit produced cold THE PIPE CONNECTION HAS TO BE UNDERTAKEN BY A PROFESSIONNAL gas nitrogen Connect the 2 units by a copper line 1 4 for the line The nuts are provided Put them on the copper rigid pipe before performing maximum elevation is 10 meters The number of bends Gas loading R...

Страница 11: ...E UNIT HAS TO BE INSTALLED RESPECTING THE NATIONAL RULES OF ELECTRIC MANUAL WINESP40CAPRO Connection of outside unit Unscrew and remove the cover from outside unit Unscrew the cover from the waterproof box Connect the box and the outside unit via the 4G1 5 cord not supplied Connection of inside unit Unscrew and remove the front cover ug the power cord as per wiring drawing 3 5 4 The connecting box...

Страница 12: ...INSTALLATION AND USER MANUAL 3 5 4 Wiring drawing MANUAL WINESP40CAPRO Page 13 ...

Страница 13: ...NG THE AIR CONDITIONER WINEMASTER The thermostat indicates the temperature in the wine cellar with a precision of 2 C A temperature variation of the air doesn t mean the same variation of the liquid due to the thermal capacity of the liquid The thermostat is set at 12 C in the factory During the installation the set temperature must be 4 2 1 Connecting the air conditioner When you plug the unit to...

Страница 14: ... fan on high speed Red light defrost Red light heating mode engaged resistance 4 2 2 Standby mode Standby mode maintain 3 seconds on button 1 The compressor stops and the fan turns at low speed The thermostat indicates OFF and also the cellar temperature To come back maintain again a 3 seconds pressure on button 1 The thermostat indicates ON during 1 second 4 2 3 Automatic defrost The program of t...

Страница 15: ... equipped with a washable and reusable filter Unscrew the 2 plastic screws 1 Remove the filter cover 2 Take the filter out 3 Wash the filter with warm water Once the filter cleaned and drained replace the filter back and close CHECK AND CLEAN THE FILTER REGULARLY DUSTED FILTER DAMAGE ON THE AIR CONDITIONER CHECK AND CLEAR THE OPENINGS REGULARLY CLOGGED AIR INLET DAMAGED AIR CONDITIONER a year Page...

Страница 16: ... of the purchase invoice or for lack of its copy 6 4 Exclusions and limitations of warranty The warranty can be refused in following cases Insulation of the cellar or installation of the appliance not in compliance with the instructions of this guide Damages due to negligence lack of maintenance or incorrect use of the air conditioner WINEMASTER particularly clogged filters Exchange of parts or re...

Отзывы: