58
Humidity too low, without optional humidifier
Possible Cause
Solution
No moisture being added to cellar
Add Wine Guardian humidifier or a room
humidifier
Humidity too low, with optional humidifier
Possible Cause
Solution
Humidifier not operating
Humidifier operating
Check wiring for loose, broken or frayed
connections
Check humidistat set up
Check for water flow and solenoid valve
operation
Check for water being hot
Check drip pad – replace if scaled
No vapor barrier around cellar
Humidity too high when unit is running but not cooling
Possible Cause
Solution
Compressor not operating
Ambient temperature is too high
Check and reset high limit switch
Clear blockage of condenser airflow
Reduce temperature or draw condenser air from
another space
Humidity too high when unit is not running
Possible Cause
Solution
Unit needs to run to dehumidify
Run unit. Seal openings around doors (gasket
and sweep)
Humidity too high when unit is running and cooling
Possible Cause
Solution
Too much moisture in cellar
Poor vapor barrier installation
Humidifier malfunction refer to the humidifier
instructions
Add dehumidifier to surrounding space
Содержание 15H0128-00
Страница 11: ...11 Fig 2 Overview of the Wine Guardian fan coil Fig 1...
Страница 13: ...13 Ducted split system specifications sheet...
Страница 14: ...14 Wiring Diagram for SS025 and SS050 Units Fig 4...
Страница 15: ...15 Wiring Diagram for SS088 Units Fig 5...
Страница 16: ...16 Wiring Diagram for SS200 Units Fig 6...
Страница 17: ...17 24 Volt Contactor Detail Sheet Fig 7...
Страница 27: ...27 Rod Mount Fig 2 Shelf Mount Fig 3 Optional ductwork connection on same wall Fig 4...