background image

2

3

Contents

Before fitting ........................................................................................................

3

Contents in screw bag .........................................................................................

3

Position/fitting .....................................................................................................

4

Use and maintenance ..........................................................................................

5

Connection diagram ............................................................................................

8

Technical specifications.......................................................................................

8

Information about the unit...................................................................................

9

Warranty............................................................................................................... 11

General

THERMOLUX split units is a Norwegian produced high-quality product with selected

components, with 30 years' experience. The units are supplied in 3 sizes: from 1-8 M3

from 2-12M3 and from 4-17M3. Quick to fit, easy to use and extremely quiet.

The room where the hot is placed must have good ventilation during the summer, so

that the average temperature does not exceed 27 degrees. Fitting of the splits units 

must be conducted by an approved refrigeration engineer and conducted according 

to UK refrigeration standards.

The hot and cold parts are connected with 8 mm and 6 mm copper pipes, which are

insulated, and a cable of a min. of 0.75 square, 3 wires + earth.

2

The refrigeration units are suitable for private households and commercial 

establishments.  Hot and cold is seperated, and the cold part (evaporator) is fitted 

in the cellar or wine room, which should be adequately insulated, while the hot part 

is placed in a separate area.

Before fitting

Unwrap the unit and check that all the parts in the list are present. Contact the supplier

if there are any deficiencies or parts missing.

You need to use 6 mm and 8mm (5/16” & ¼”) approved copper pipes on the TL6 and

TL10 models. TL16 uses ¼” & 3/8”. The electrical cable between the evaporator and

compressor part must be 3-wires + earth. (4x0.75).

It must be connected to the drain under the evaporator, which is fed to a drain/

container. When connecting to the drain you must create a water trap.

The cooling pipes must be put in place or with a slight drop from the highest point above

the evaporator back to the compressor part, and the oil lock on the suction tube at a

height difference of + 1.5 m up to the compressor part again.

Associated parts

1 x  User and fitting instructions

2 x 5 pin male connector with cover for electrical connection between hot and 

cold section.

4 x  Rubber mufflers for metal box heat part.

1 x  thermostat for walls/ceiling evaporators.

2 x  discs used together with 2 x 4x40 for heat part attachment.

4 x  3.5x13 screws used together with 5-pin male connector.

5 x  4x40 screw for attaching hot and cold part.

4 x  4.2x15 screws for fixing plastic cover ceiling evaporator and heat part.

1 x  rubber rinse tube for walls/ceiling evaporator.

3

Energizer Split

Wall evaporator

Ceiling evaporator

Compressor unit TL6-10-16

Отзывы: