background image

 

windy

nation

 

 

 

Revision 3 

VertaMax User Manual

 

Page 7 of 16

 

 

 

IMPORTANT: 

When fully tightened, the Cable Lug should not be able to rotate around the 

Inverter connection post. Check and tighten the end caps periodically as they can become 

loose from vibrations or thermal cycling. 

6)  Connect cables to the power source: 

a)  Connect the cable from the Negative (Black) Terminal of inverter to the Negative 

Terminal of the power source; ensure a secure connection. 

b)  Connect the cable from the Positive (Red) Terminal of the inverter to the Positive 

Terminal of the power source (the battery’s main fuse or the battery selector switch, if 

you are using one); ensure a secure connection. 

2.4.1 

Permanent AC Connection* 

*Not available on all models 

WARNING:

 If you are making a permanent AC connection to the inverter, make sure that the AC 

wiring is performed before any DC wiring is done. (DC hook-up may energize internal 

components and create an electrical shock hazard). 

1.  Remove the wiring compartment cover to expose the terminal blocks 

 

2.  Strip about 2” from the jacket of AC output cable 

a.  AC output cable may be solid or stranded but must have three conductors up 

to 10AWG each 

3.  Strip approximately 3/8” off the insulation to expose the conductor 

4.  Run AC cable through the strain relief clamp and into wiring area 

 

5.  Insert the Ground, Line, and Neutral wires into the corresponding terminals 

Label 

AC Wire 

Cable Color 

GND 

Ground 

Green or bare copper 

Neutral 

White 

Line 

Black 

Содержание VertaMax PIN-1500-12M

Страница 1: ...windynation VertaMax Power Inverter PIN 1500 12M PIN 3000 12M User s Manual...

Страница 2: ...on Alarms 9 3 3 1 Over Input Voltage 9 3 3 2 Low Input Voltage 9 3 3 3 Power Overload 9 3 3 4 Over Heating 10 3 3 5 Short Circuit 10 3 3 6 Functional Matrix 10 4 Application 10 4 1 Power Consumption 1...

Страница 3: ...roprocessor Based PWM Pulse Width Modulation Operation Three AC Receptacles with Circuit Breakers Soft Start Digital Display Voltage and Power Meter Power On OFF Switch and LED indicator Remote On Off...

Страница 4: ...by Current 0 80A 1 0A Low Battery Voltage Alarm 10 5 VDC 0 3VDC Low Battery Voltage Shutdown 10 0 VDC 0 3VDC High Battery Voltage Shutdown 16 VDC 0 5VDC Efficiency 85 90 1 3 2 Physical Specifications...

Страница 5: ...e system negative conductor to this terminal NEC requires the use of an external ground fault protection device GFPD The system electrical negative should be bonded through a GFPD to earth ground at o...

Страница 6: ...or that provides a secure low resistance connection For example if the power source is a battery the cable must be terminated with a battery terminal that clamps to the post on the battery IMPORTANT I...

Страница 7: ...sing one ensure a secure connection 2 4 1 Permanent AC Connection Not available on all models WARNING If you are making a permanent AC connection to the inverter make sure that the AC wiring is perfor...

Страница 8: ...urce is ON if switched From the AC Output end of the inverter switch the rocker power switch to the ON position The green power indicator will light and the VertaMax will now deliver AC power to the o...

Страница 9: ...IMPORTANT Although the inverter incorporates protection against over voltage it is still possible to damage the unit when the input voltage exceeds 15V DC 3 3 2 Low Input Voltage As a battery is used...

Страница 10: ...onal Mode Power Switch Power Light Fault Light Audible Alarm Unit is off Off Off Off Off Normal Operation On On Off Off Low input voltage 11V On On Off On Low input voltage 10 5V On On On On Low input...

Страница 11: ...G 12AWG 10AWG 8AWG 6AWG 6AWG 4AWG 2AWG 2AWG 1 0AWG 3 0AWG 4 0AWG 8 16AWG 14AWG 12AWG 10AWG 8AWG 6AWG 6AWG 4AWG 2AWG 2AWG 1 0AWG 3 0AWG 4 0AWG 10 16AWG 14AWG 12AWG 10AWG 8AWG 6AWG 6AWG 4AWG 2AWG 2AWG 1...

Страница 12: ...veral hours For a deep cycle battery at 77 F 25 C use the following table Battery Voltage State of Charge 12 7 13 0 V 100 12 5 12 6 V 80 12 3 12 4 V 60 12 1 12 2 V 40 11 9 12 0 V 20 4 4 3 Actual Batte...

Страница 13: ...e or several batteries you should connect to your Inverter NOTE Battery amp hour ratings are usually given for a 20 hour discharge rate Actual amp hour capacities are less when batteries are discharge...

Страница 14: ...far as possible from electronic equipment antenna and cables Make sure the chassis ground connection on the inverter is solidly connected Keep battery cables as short as possible and twist them togeth...

Страница 15: ...r warranty service shall be shipped at the expense and risk of the Customer The Customer must return the entire Product kit or if authorized by Windy Nation the defective component parts within fiftee...

Страница 16: ...GARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE EVEN IF WINDY NATION OR ITS AFFILIATE OR SUPPLIER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH...

Отзывы: