VertaMax User Manual

 

Revision 3 

 

Do not operate the VertaMax near flammable fumes or gases, such as in the cabin of a gasoline 

powerboat, or near propane tanks. 

 

Never work or service the AC wiring without disconnecting the DC Input connections. 

 

Do not connect or disconnect batteries while the Inverter is operating from the battery supply. 

Dangerous arcing may result. 

 

Although the inverter has over-voltage protection, the input voltage should never exceed 15V. 

Input voltages of 16VDC or more will permanently damage the inverter. 

 

Due to high voltages inside the inverter, the inverter should never be opened when in use. 

1.3 S

PECIFICATIONS

 

1.3.1 

Electrical Specifications 

Parameter  

PIN-1500-12M 

PIN-3000-12M 

Continuous Rated Power 

1500 Watts 

3000 Watts 

Peak Surge Power 

3000 Watts 

6000 Watts 

Input Voltage (Nominal) 

12 – 13 VDC 

Input Voltage (Min – Max) 

11 – 15VDC 

Output Voltage (Nominal) 

115VAC 

Output Frequency (Nominal) 

60 Hz 

Output Waveform 

Modified Sine Wave 

Standby Current 

<0.80A 

<1.0A 

Low Battery Voltage Alarm 

10.5 VDC (+/-0.3VDC) 

Low Battery Voltage Shutdown 

10.0 VDC (+/-0.3VDC) 

High Battery Voltage Shutdown 

16 VDC (+/-0.5VDC) 

Efficiency 

85-90% 

1.3.2 

Physical Specifications 

Parameter 

 

PIN-1500-12M

 

PIN-3000-12M

 

Dimension (L x W x H) 

13.0” x 8.7” x 3.0” 

(330mm x 221mm x 76mm)

 

16.7” x 10.3” x 3.7” 

(425mm x 262mm x 94mm)

 

Unit Weight 

8.2 lb. (3.7kg) 

15.4 lb. (7.0kg) 

Cooling 

Auto Powered Fan 

Operating Temperature 

0

o

C to 60

o

Storage Temperature 

-25

o

C to 70

o

Operating Humidity 

20 to 80% relative humidity (non-condensing) 

Thermal Protection 

>65

o

 

2  INSTALLATION 

  Insure all terminating connections are clean and tight to prevent arcing and overheating. 

  The VertaMax must be installed in an area that satisfies all of the following conditions: 

1.  Dry: Avoid any location where water can contact the inverter 

2.  Cool: Ambient air temperature between 30°F and 105°F (0°C and 40°C) 

3.  Ventilated: Allow at least 6 in (150 mm) of clearance above and below and at least 

1 in (25 mm) on each side for proper air flow. 

4.  Safe: Do not operate in a shared compartment with batteries or any flammable 

substances, (e.g.: gasoline) 

 

IMPORTANT:

 To avoid fire, do not cover or obstruct ventilation openings. 

Содержание VertaMax PIN-1500-12M

Страница 1: ...windynation VertaMax Power Inverter PIN 1500 12M PIN 3000 12M User s Manual...

Страница 2: ...on Alarms 9 3 3 1 Over Input Voltage 9 3 3 2 Low Input Voltage 9 3 3 3 Power Overload 9 3 3 4 Over Heating 10 3 3 5 Short Circuit 10 3 3 6 Functional Matrix 10 4 Application 10 4 1 Power Consumption 1...

Страница 3: ...roprocessor Based PWM Pulse Width Modulation Operation Three AC Receptacles with Circuit Breakers Soft Start Digital Display Voltage and Power Meter Power On OFF Switch and LED indicator Remote On Off...

Страница 4: ...by Current 0 80A 1 0A Low Battery Voltage Alarm 10 5 VDC 0 3VDC Low Battery Voltage Shutdown 10 0 VDC 0 3VDC High Battery Voltage Shutdown 16 VDC 0 5VDC Efficiency 85 90 1 3 2 Physical Specifications...

Страница 5: ...e system negative conductor to this terminal NEC requires the use of an external ground fault protection device GFPD The system electrical negative should be bonded through a GFPD to earth ground at o...

Страница 6: ...or that provides a secure low resistance connection For example if the power source is a battery the cable must be terminated with a battery terminal that clamps to the post on the battery IMPORTANT I...

Страница 7: ...sing one ensure a secure connection 2 4 1 Permanent AC Connection Not available on all models WARNING If you are making a permanent AC connection to the inverter make sure that the AC wiring is perfor...

Страница 8: ...urce is ON if switched From the AC Output end of the inverter switch the rocker power switch to the ON position The green power indicator will light and the VertaMax will now deliver AC power to the o...

Страница 9: ...IMPORTANT Although the inverter incorporates protection against over voltage it is still possible to damage the unit when the input voltage exceeds 15V DC 3 3 2 Low Input Voltage As a battery is used...

Страница 10: ...onal Mode Power Switch Power Light Fault Light Audible Alarm Unit is off Off Off Off Off Normal Operation On On Off Off Low input voltage 11V On On Off On Low input voltage 10 5V On On On On Low input...

Страница 11: ...G 12AWG 10AWG 8AWG 6AWG 6AWG 4AWG 2AWG 2AWG 1 0AWG 3 0AWG 4 0AWG 8 16AWG 14AWG 12AWG 10AWG 8AWG 6AWG 6AWG 4AWG 2AWG 2AWG 1 0AWG 3 0AWG 4 0AWG 10 16AWG 14AWG 12AWG 10AWG 8AWG 6AWG 6AWG 4AWG 2AWG 2AWG 1...

Страница 12: ...veral hours For a deep cycle battery at 77 F 25 C use the following table Battery Voltage State of Charge 12 7 13 0 V 100 12 5 12 6 V 80 12 3 12 4 V 60 12 1 12 2 V 40 11 9 12 0 V 20 4 4 3 Actual Batte...

Страница 13: ...e or several batteries you should connect to your Inverter NOTE Battery amp hour ratings are usually given for a 20 hour discharge rate Actual amp hour capacities are less when batteries are discharge...

Страница 14: ...far as possible from electronic equipment antenna and cables Make sure the chassis ground connection on the inverter is solidly connected Keep battery cables as short as possible and twist them togeth...

Страница 15: ...r warranty service shall be shipped at the expense and risk of the Customer The Customer must return the entire Product kit or if authorized by Windy Nation the defective component parts within fiftee...

Страница 16: ...GARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE EVEN IF WINDY NATION OR ITS AFFILIATE OR SUPPLIER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH...

Отзывы: