background image

To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com

INSPECTION

Carefully unpack and inspect your extractor for shipping dam-

age. Each unit is operated and thoroughly inspected before ship-

ping, and any damage is the responsibility of the carrier, who
should be notified immediately.

ELECTRICAL

This extractor operates on a standard 15 amp 115 volt AC cir-
cuit. *Voltages below 105 volts or above 125 volts could cause
serious damage to motors. 
 *Special voltage models available.

WARNING: 

To avoid electric shock

:

1.   Use indoors only.

2.   To reduce risk of fire, do not use volatile substances.

3.   Use only cleaners intended for carpet application.

   
   

   

 

 

NOTE:  Au Canada, l’utilisation d’un adaptateur 

temporaire n’est pas autorisée par le 
Code canadien de l’électricité.

NOTE: In Canada, the use of a temporary adaptor is 

not permitted by the Canadian Electrical Code

GROUNDING INSTRUCTIONS:

This appliance must be grounded.  If it should malfunction or

break down, grounding provides a path of least resistance for

electric current to reduce the risk of electric shock.  This ap-

pliance is equipped with a cord having an equipment–grounding

conductor and grounding plug.  The plug must be inserted into

an appropriate outlet that is properly installed and grounded in

accordance with all local codes and ordinances. 

This appliance is for use on a nominal 120–volt circuit, and has

a grounded plug that looks like the plug in “Fig. A”.  A tempo-

rary adaptor that looks like the adaptor in “Fig . C”  may be used

to connect this plug to a 2–pole receptacle as shown in “Fig. B”,

if a properly grounded outlet is not available.  The temporary

adaptor should be used only until a properly grounded outlet

(Fig. A) can be installed by a qualified electrician.  The green col-

ored rigid ear, lug, or  the like extending from the adaptor must

be connected to a permanent ground such as a properly grounded

outlet box cover.  Whenever the adaptor is used, it must be held

in place by a metal screw.

WARNING: 

Improper connection of the equipment–grounding conductor

can result in a risk of electric shock.  Check with a qualified

electrician or service person if you are in doubt as to whether

the outlet is properly grounded.  Do not modify the plug pro-

vided with the appliance – if it will not fit the outlet, have a prop-

er outlet installed by a qualified electrician.

EXTENSION CORDS

If an extension cord is used, the wire size must be at least one
size larger than the power cord on the machine: The POWER

ESCORT is equipped with a 50 ft. 114/3 power cord.

 Do not

exceed the 50 ft. cord limit.

CAUTION:
To avoid possible distortion of polyethylene solution/
recovery tanks, DO NOT USE WATER TEMPERATURE
THAT EXCEEDS 140

°

 F (60

°

 C).

NOTE: 

Make sure dome is seated correctly to ensure proper vacuum

seal.

SUITABLE

INCOMPATIBLE

CHEMICALS

CHEMICALS

Alkalis

Aldehydes

Clorox II Bleach*

Aromatic Hydrocarbons

Defoaming Agents

Butyls

Detergents

Carbon Tetrachloride

Hydroxides

Clorox*

Oxygen Bleaches

Chlorinated Bleaches

Soaps

Chlorinated Hydrocarbons

Sta–Puf Fabric Softener*

D–Limonene

Vinegar Lysol*

White Monday Bleach*

Methyls (MEK)

Perchlorethylene(perc)

Phenols

* Registered Trademark

Trichlorethylene

CAUTION:
Use only the suitable chemicals listed below.  Using in-
compatible chemicals will damage the machine.  Dam-
ages of this type are not covered under the 6–3–1 war-
ranty.  Carefully read ingredients on manufacturer’s la-
bel before using any product in this machine.

3

98255  7/1/97

Содержание EPB2

Страница 1: ...TRIES INC 1351 W Stanford Ave Englewood CO 80110 USA 303 762 1800 FAX 303 762 0817 CONTENTS 2 Safety Instructions 3 Grounding Instructions 4 Operating the Extractor 5 Operations and Maintenance 6 Service 7 Chassis assembly 8 Brush Housing and Drive Assembly 10 Tank Assembly 12 Wiring Diagrams 13 Notes 14 Warranty 98255 9 15 97 ...

Страница 2: ...ine from outlet when not in use and before servicing 10 Do not unplug machine by pulling on cord To unplug grasp the plug not the cord 11 Do not use with damaged cord or plug Follow all instructions in this manual concerning grounding the machine 12 If the machine is not working properly has been dropped damaged left outdoors or cropped into water return it to an Authorized service center 13 Do no...

Страница 3: ...unded outlet is not available The temporary adaptor should be used only until a properly grounded outlet Fig A canbeinstalledbyaqualifiedelectrician Thegreencol ored rigid ear lug or the like extending from the adaptor must beconnectedtoapermanentgroundsuchasaproperlygrounded outlet box cover Whenever the adaptor is used it must be held in place by a metal screw WARNING Improper connection of the ...

Страница 4: ...work check to see if there is a foam buildup in the recovery tank If there is a foam buildup turn the machine off and add the recommended amount of a defoaming solution to the recovery tank NOTE Never put defoamer in the solution tank WARNING An overflow of foam into the vacuum intake can damage the vac motor Always be aware of the waste water level in the recovery tank When the tank is about thre...

Страница 5: ...ead DO NOT OVER TIGHTEN as this could crack intake and discharge ports in pump head PERIODIC MAINTENANCE Twice a month flush a white vinegar solution One quart vinegar to two gallons of water or anti browning solution mixed as directed through the POWER ESCORT This will prevent build up of alkaline residue in the system If spray jets become clogged remove the spray tips wash them thoroughly and bl...

Страница 6: ... machine back to rest on handle 3 Remove hex nut from PVC muffler Repair or replace as needed POWER HEAD LIFT CABLE 1 Remove recovery tank vac motor assembly 2 Tilt machine back to rest on handle Remove bolt holding cable to lift bracket and 2 power head pivot bolts 3 Remove guide pulley bracket assembly and remove from pulley 4 Remove pedal and bracket assembly 4 screws Replace cable as required ...

Страница 7: ...Washer 9 16 ID x 1 06 OD 28 56014 Nipple 1 4 Close 29 40038 Hosebarb 1 4 MPT x 3 8 45D 30 78156 Tee 1 4 FPT 31 84065 Valve 1 4 FPT Ball 32 56012 Nipple 1 4 FPT QD 33A 50399 Label L1500 Warning 33B 50577 Label Warning Caution Japan 34 70091 Screw 10 24 x 1 2 FHMS 35 73197 Strain Relief 90 D 36 48028 Knob Yellow Ball Valve 37 50540 Label Valve position Symbol 38 34128 Frame EBP 2 Main 39 03075 Axle ...

Страница 8: ...47 48 49 50 51 15 16 41 42 43 44 45 46 38 39 34 16 15 40 39 38 40 39 38 37 36 35 32 77 30 15 53 48 47 52 55 56 31 32 8 10 6 7 7 98255 9 16 97 H 33 Ref Qty Part No Description Serial No Notes From To 1 53513 Motor 115V DC Brush Drive 2 35071 Gasket 1 8 x 1 x 5 3 87014 Washer 8 Int Star 4 70052 Screw 8 32 x 3 8 PHMS 5 62225 Plate Assembly Motor 6 87018 Washer 10 x 9 16 OD 7 57030 Nut 10 32 Nylock 8 ...

Страница 9: ...ket Cable Roller 43 64034 Roller 44 73206 Spacer 259 ID x 3 8 OD x 1 2 45 70018 Screw 1 4 20 x 1 HHMS 46 62130 Plate Pump 47 73208 Spacer 3 4 OD x 208 Wht Nylon 48 57113 Nut 5 16 18 Lock 49 73210 Spring Pedal Release 50 70217 Shoulder Bolt 3 8 OD x 1 25L 51 73219 Spacer 57 OD x 3 4 L Nylon 52 66076 Pedal Assembly Left 53 57005 Nut 10 24 Hex 54 70223 Eyebolt 3 16 w 10 24 Nut 55 66078 Pedal Right 56...

Страница 10: ... 49 50 51 23 53 52 54 55 56 57 58AB 59 60 61 62 63 64 65 66 17 17 25 25 63 67 15 TANK ASSEMBLY 10 33B 5 2 3 98255 11 13 97 69 68 Ref Qty Part No Description Serial No Notes From To 1 73250 Strainer 80 Mesh x 3 8 FPT 2 14076 Bushing 3 8 MPT x 1 4 FPT hex 3 87015 Washer 9 16 x 1 06 OD 4 56014 Nipple 1 4 Close 5 75082 Tank EPB 2 Solution 6 36055 Grommet 1 2 ID x 1 4 Grrove 7 50379 Label EPB 2 Main 8 ...

Страница 11: ... 31045 1 5 MS x FS PVC 35 34140 Filter Vac Intake 10 Mesh 36 28029 Dome Assembly 37 35060 Gasket S C Dome 38 27274 Cuff 1 5 Swivel Hose 39 39072 Hose Asm 1 5 x 4 Vac Swivel 40 27167 Hose Cuff 1 5 41 73505 Strain Relief 42 70085 Screw 1 4 20 x 1 2 PHMS 43 72033 Switch Momentary On Off 115V 44 72004 Switch Illuminated Rocker 115V 45 50271 Label Control Panel 115V 46 61167 Control Panel 115V 47 72035...

Страница 12: ...T o O r d e r P a r t s C a l l 1 8 8 8 7 0 2 5 3 2 6 h t t p s m o n s t e r f l o o r e q u i p m e n t p a r t s c o m 115 VOLT WIRING DIAGRAM 100 VOLT WIRING DIAGRAM 12 98255 9 16 97 ...

Отзывы: