24
Maintenance
Checking Battery Specific Gravity
Use a hydrometer to check the battery specific gravity.
CHECKING GRAVITY
a.
Hydrometer
b.
Battery
NOTE: Do not take readings immediately after adding
distilled water, if the water and acid are not
thoroughly mixed, the reading may not be accurate.
Check the hydrometer readings against this chart.
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 80°F (27°C),
the reading must be temperature corrected.
To find the corrected specific gravity reading when the
temperature of the battery electrolyte is other than 80°F
(27°): Add (+) to the specific gravity reading 0.004 (4
points), for each 10°F (6°C) above 80° (27°C).
Subtract (-) from the specific reading 0.004 (4 points),
for each 10°F (6°C) below 80°F (27°C).
To Charge The Batteries
When servicing machine, avoid contact with
battery acid.
Lors de l'entretien de la machine, évitez tout
contact avec l'acide de batterie.
Batteries emit hydrogen gas. Explosion or fire can
result. Keep sparks and open flame away. Keep
covers open when charging.
Les batteries émettent du gaz hydrogène. Une
explosion ou un incendie peut en résulter.
Maintenez les étincelles et les flammes nues à
l’écart. Gardez les carters ouverts lors du charge-
ment.
Wear eye protection and protective clothing when
working with batteries.
Portez des lunettes de protection et des vêtements
de protection lorsque vous travaillez avec des
batteries.
Charge batteries in a well ventilated area. Leave
the battery cover open.
Chargez les batteries dans un endroit bien ventilé.
Gardez les carters ouverts lors du chargement.
Use a 36 volt, 18 amp maximum output or 25 amp
(depending on the size of the batteries), DC charger
which will automatically shut off when the batteries are
fully charged.
1.
Stop the machine in a clean, well ventilated area
next to the charger.
2.
Turn "OFF" machine.
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, turn off machine
and remove key.
3.
Raise the battery cover
SPECIFIC GRAVITY @
80
°
F (27
°
C)
BATTERY CONDITION
1.265
100% CHARGED
1.225
75% CHARGED
1.190
50% CHARGED
1.155
25% CHARGED
1.120
DISCHARGED
86400280 Operators Manual - Cutter 36V Standard