22
2.
Operation
1.)
Close the vertical grate.
2.) First add smaller then larger
split logs
of increasing
length and fill up filling chamber as required – Fig.
54. Before closing the lighting door, check that there
is wood just in front of the ignition opening.
Fig. 54 Section through the filling chamber
Hardwood or softwood
logs edge length
8 – 15 cm
Hardwood or softwood
logs edge length
3 – 4 cm
Not
e!
For reliable and efficient ignition, it is im-
portant that there is wood just in front of the
ignition opening.
2.8.3 Heating up with automatic ignition
1
3.)
Close lighting door, filling door and cladding door.
„Ignition“ displayed on InfoWIN – Fig. 55.
4.)
Press Ignition button,
„Instant“, „With off period“ and „Automatic“ are shown on the display – Fig. 56.
5.) The
arrow
buttons select the desired type of ignition; the
Choose
button confirms the choice – Fig. 56.
Types of ignition:
„Instant“:
The ignition phase begins immediately after selection.
„With off period“: Pressing the
+
or
–
button changes the time in 15 min. steps and pressing
save
confirms
this choice – Fig. 57.
The ignition phase only starts once the set time has elapsed and a heating request has
been generated by MESplus control or an external ignition request.
„Automatic“:
The ignition phase begins when there is a heating request from the MESplus control or an
external ignition request.
With the „With off period“ and „Automatic“ types of ignition, the
Cancel
button can be used to cancel the „Ignition
ready“ operating phase.
Information!
Before filling, ensure that there are no em-
bers in the filling chamber – uncontrolled
spontaneous ignition possible!
1 Only for LogWIN with automatic ignition (accessory).