background image

The “Clean boiler and burner” cleaning request is displayed

Display on InfoWINplus IN 590 or FE 390
The FireWIN is equipped with a cleaning interval display. The cleaning request for the combustion chamber and 
burner pot is displayed on the InfoWINplus and must be reset after cleaning has finished.
Cleaning:
a)  Take out the baffle plate and remove the ash.
b)  Clean fly ash off the temperature sensor with a cleaning brush.
c)  Cleaning the down chute.
d)  Clean burner pot.
e)  Empty the ash pan(s) or remove the ash from the heating surface duct.
f)  Check that there is not too much dust in the FireWIN reserve supply container and that there is no bridge for-

mation – remove the dust.

Cleaning the baffle plate

Temperature sensor             Down chute

Te

ch

ni

sc

he

 Ä

nd

er

un

ge

vo

rb

eh

al

te

n.

 A

W

P

-v

or

be

rs

et

ut

 a

us

 0

23

74

5/

05

Removing ash

FireWIN Klassik and Premium approx. every 400 kg pellets or FireWIN Exklusiv approx. every 1200 kg pellets

a)  Connect the heating surface cleaning lever (FireWIN Klassik/Premium only) and move it backwards and for-

wards several times.

b)  Empty the ash pan(s) or remove the ash from the heating surface duct.

Connect the lever and operate it several times

Empty the ash pan(s) or remove the ash 
from the heating surface duct

Ash pan for 
heating surfaces 
(accessories)

Ash pan for
combustion 
chamber

Detail

1 ........... Cleaning tool or cone removal too
2 ........... Guide groove for the lock the Cone in the burner pot
3 ........... Cone
4 ........... Primary air pin
5 ........... Grate plate
6 ........... Secondary air holes
7 ........... Lock for cone
8 ........... Burner pot

Cleaning the thermocontrol sensor and down chute

Resetting the cleaning request

After the combustion chamber and burner pot have been cleaned, the operating hours counter for boiler cleaning
must be reset.

Boiler cleaning

Time
Feed operating mode
Time profile feed
Probe switching

 

 

Choose 

Back 

Selecting “Boiler cleaning”

Has boiler and burner cleaning
been performed?

Confirm

 

 

Yes  

Back 

Confirming with the Yes button

At least once per heating season

see operating manual.

Press  the  Reset  button  or  switch  on  the  boiler  at 
the  InfoWINplus.  Wait  for  the  self-test  to  finish, 
press the Menu button and change to operator le-
vel.  Select  the  „Boiler  cleaning“  sub-menu  in  the 
operator  level  and  confirm  by  pressing  Yes.  The 
counter is reset.