The “Clean boiler and burner” cleaning request is displayed
Display on InfoWINplus IN 590 or FE 390
The FireWIN is equipped with a cleaning interval display. The cleaning request for the combustion chamber and
burner pot is displayed on the InfoWINplus and must be reset after cleaning has finished.
Cleaning:
a) Take out the baffle plate and remove the ash.
b) Clean fly ash off the temperature sensor with a cleaning brush.
c) Cleaning the down chute.
d) Clean burner pot.
e) Empty the ash pan(s) or remove the ash from the heating surface duct.
f) Check that there is not too much dust in the FireWIN reserve supply container and that there is no bridge for-
mation – remove the dust.
Cleaning the baffle plate
Temperature sensor Down chute
Te
ch
ni
sc
he
Ä
nd
er
un
ge
n
vo
rb
eh
al
te
n.
A
W
P
-v
or
-ü
be
rs
et
ut
a
us
0
23
74
5/
05
Removing ash
FireWIN Klassik and Premium approx. every 400 kg pellets or FireWIN Exklusiv approx. every 1200 kg pellets
a) Connect the heating surface cleaning lever (FireWIN Klassik/Premium only) and move it backwards and for-
wards several times.
b) Empty the ash pan(s) or remove the ash from the heating surface duct.
Connect the lever and operate it several times
Empty the ash pan(s) or remove the ash
from the heating surface duct
Ash pan for
heating surfaces
(accessories)
Ash pan for
combustion
chamber
Detail
1 ........... Cleaning tool or cone removal too
2 ........... Guide groove for the lock the Cone in the burner pot
3 ........... Cone
4 ........... Primary air pin
5 ........... Grate plate
6 ........... Secondary air holes
7 ........... Lock for cone
8 ........... Burner pot
Cleaning the thermocontrol sensor and down chute
Resetting the cleaning request
After the combustion chamber and burner pot have been cleaned, the operating hours counter for boiler cleaning
must be reset.
Boiler cleaning
Time
Feed operating mode
Time profile feed
Probe switching
Choose
Back
Selecting “Boiler cleaning”
Has boiler and burner cleaning
been performed?
Confirm
Yes
Back
Confirming with the Yes button
At least once per heating season
see operating manual.
Press the Reset button or switch on the boiler at
the InfoWINplus. Wait for the self-test to finish,
press the Menu button and change to operator le-
vel. Select the „Boiler cleaning“ sub-menu in the
operator level and confirm by pressing Yes. The
counter is reset.