34
3.
For the Electrician
Cable duct
Low voltage
(230 V AC)
Cable duct
Extra-low voltage
(sensor)
Fig. 92 Open control panel, BioWIN 2 with MESplus control – view from front
Mains power plug (230 V AC)
Fig. 93 Cable feed-throughs in the cladding of the BioWIN 2 – view from rear
Information!
Be sure to note the separate wiring of the extra-low voltage line (sensor) and low-voltage line
(230 V A
C)! – Fig. 92.
The terminal block connection (screwless cage-spring-type terminals) is executed with a fine-wire PVC sheathed
cables – Fig. 92.
The cables can be laid from the top, bottom, right and rear, through the pre-punched feed-throughs (Fig. 93).
Connection diagrams for the control are enclosed, for more connection diagrams, see section 6.
main board
screwless cage-
spring-type termi-
nals for MESplus
control or REG
control