21
2.
For the Installer
2.4.8 Install reserve supply container
– First insert the reserve supply container together with the auger into the auger tube (Fig. 34) and hook into
place into the 2 hooks, marked yellow – Fig. 35.
– Tighten the fastening screws at the top as securely as possible (marker) – Fig. 36.
– Remove the cover from the reserve supply container by unscrewing the two screws on its bottom side (Fig. 37)
and push the cover down to take it off completely (it is attached with a bayonet catch) – Fig. 38.
– Screw the base of the reserve supply container to the auger tube with M8 x 16 hexagon screws (provided, at-
tached to reserve supply container in a plastic bag) – Fig. 39.
Fig. 36 Insert the auger into the auger
tube
Fig. 37 Suspend reserve supply container
from 2 hooks, marked
Fig. 38 Tighten fastenings at top as firmly
as possible (marker)
Fig. 39 Remove cover, removing the 2 screws
Fig. 40 Push down cover and remove
Cover
Fig. 41 Tighten screws at base of reserve supply
container
1 x
M8x16