background image

WINDCHASER PRODUCTS • ENGLISH

Thank you for choosing WINDCHASER PRODUCTS.  We hope this product

will give you complete satisfaction.   If however a problem occurs, please

contact your dealer or our customer service department.

C

ONTENTS

READ AND KEEP INSTRUCTIONS

SAFETY POWER SUPPLY CORD

This unit is provided with a Leakage Current
Detection and Interruption circuit (LCDI) built into
the plug of the power supply cord.  This device
provides protection to reduce the risk of fire due to
arcing faults in the power-supply cord. Each time
before using the Room Air Conditioner, follow the
"Plug Testing Instructions" given below to ensure
that the LCDI circuit is functioning properly.

PLUG TESTING INSTRUCTIONS:

1. PRESS TEST BUTTON. UNIT SHOULD TRIP.
2. PRESS RESET BUTTON FOR USE.

DO NOT USE IF ABOVE TEST FAILS.

The conductors inside this power supply cord are
surrounded by shields which monitor the leakage
current. These shields are not grounded. Periodi-
cally examine the cord for any damage. If the shield
gets exposed, immediately unplug the power
supply cord and do not use the unit.

Do not repair a damaged cord. Replace the damaged
cord only with a new replacement power supply cord
obtained from the manufacturer.

In the event the LCDI Plug of the power supply cord
trips by itself, then first examine the cord for any
damage. If there is no damage to the cord then press
the RESET Button. If the LCDI Plug trips again, then
immediately unplug the power supply cord. Replace
the damaged cord with a new replacement power
supply cord.

To obtain a new replacement power supply cord
contact WindChaser Products Customer Service at:
(800) 405-2943 x102 or e-mail at:
[email protected].

Do not use The TEST and RESET Buttons as an
on / off switch. They are only meant to be used to
periodically check the LCDI plug.

VERY IMPORTANT.................................................................................................................................1
TO SAVE ENERGY................................................................................................................................. 1
TECHNICAL SPECIFICATIONS..............................................................................................................1
LEARN INTELLIGENT AIR-CONDITIONING......................................................................................... 2
SAFETY INSTRUCTIONS.......................................................................................................................2
PARTS ILLUSTRATION..........................................................................................................................3
INSTALLATION........................................................................................................................................5
OPERATING.............................................................................................................................................6
VENTILATION ONLY...............................................................................................................................6
AIR CONDITIONING................................................................................................................................ 6
TIMER PROGRAMMING..........................................................................................................................7
DEHUMIDIFICATION OPERATION........................................................................................................ 7
FAHRENHEIT & CELSIUS DISPLAY BUTTON.....................................................................................8
DRAINING EXCESS CONDENSATE WATER....................................................................................... 8
CLEANING THE APPLIANCE..................................................................................................................9
LONG TERM STORAGE..........................................................................................................................9
TROUBLESHOOTING GUIDE.................................................................................................................10
PRODUCT LIMITED WARRANTY.......................................................................................................... 11

Содержание PACR9S

Страница 1: ...INSTRUCTIONS AND MAINTENANCE MANUAL PACR9S PORTABLE AIR CONDITIONER...

Страница 2: ...unplug the power supply cord and do not use the unit Do not repair a damaged cord Replace the damaged cord only with a new replacement power supply cord obtained from the manufacturer In the event the...

Страница 3: ...t always be used in an upright position as it contains a cooling agent 2 After unpacking place the appliance upright to allow the cooling agent to stabilize and wait 3 hours before use Failure to comp...

Страница 4: ...edforanyotherpurpose Never connect the appliance to a defective socket Plug the appliance in a properly grounded dedicated 15ampsocket Checkyourbreakerboxtodetermine whichcircuitthesocketison Makesure...

Страница 5: ...rol Panel 1 Power ON OFF Button 2 Alarm Indicator Light 3 Fan ON OFF Indicator Light 4 Dehumidifier ON OFF Indicator Light 5 AC ON OFF Indicator Light 6 AC Fan Speed Indicator Lights 1 2 3 4 5 6 7 8 9...

Страница 6: ...or 3 Nozzle Fitting Cover 4 Nozzle Fitting 5 Wall If you need to extend your exhaust hose it may be extended up to 5 only using 4 P V C pipe available at your local hardware store DO NOT USE DRYER TYP...

Страница 7: ...eet long 1 Check the installation of the air filter 2 Install the exhaust hose connector 2 Fig D on the warm air outlet at the back of the appliance and turn it clockwise 3 Connect the exhaust hose 1...

Страница 8: ...button 1 Press the ON OFF Button to turn on the unit 2 Press the MODE button to select a mode function Fan Cooling or Dehumidifier 3 Select Low Medium or High Speed by pressing the fan speed button 4...

Страница 9: ...off first DEHUMIDIFICATION OPERATION Press the MODE button on the control panel or button on the remote to select the dehumidifier mode When the dehumidifier mode is on the temperature buttons and th...

Страница 10: ...Fig B Place the drain hose 6 above an empty container Remove the plug and to let the water run out the capacity of the collecting tank is about 1 5 pts Refit the plug and put the condensation drain h...

Страница 11: ...it with a clean cloth afterwards Never use alcohol or any product containing solvents AIR FILTER The air filter collects dust contained in the air To keep the dust from clogging the appliance the unit...

Страница 12: ...ket 2 Insufficient amount of amperage to start unit 3 Water tank is full alarm light illuminated 1 3 minute temporizing 2 Wrong selection of operating function 3 Air filter obstructed by dust 4 Warm a...

Страница 13: ...al utility power quality etc incorrect installation use of any power source other than that specified on the Product s specification label or repair by anyone other than a service facility specified b...

Страница 14: ...OR FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED WINDCHASER SHALL NOT BE LIABLE FOR THE LOSS OF USE OF THE PRODUCT ITS COMPONENTS ACCESSORIES AND ATTACHMENTS INCONVENIENCE LOSS OR ANY OTHER DAMAGES...

Отзывы: