Winco S300 Stretchair Скачать руководство пользователя страница 11

FIG. 3

OPERATING INSTRUCTIONS

Converting Layflat Position to Chair

1.  Lock wheels 

(FIG. 2A or 2B)

2.  Keep armrest/side-rails in the fully upright position. 

(SEE PAGE 13 FIG.3)

3.  Secure patients arms in front of their chest

4.  Using the handset control, return the chair to its sitting position. 

(FIG. 1)

5.  Raise the patient's legs and lower the footrests. Adjust to a suitable height for the patient.

 

(SEE PAGE 12)

6.  Armrests can now be lowered to a comfortable height for the patient. 

7.  Secure patient into chair with safety belt

Assisting Patient Out of Chair

1.   Lock wheels 

(FIG. 2A or 2B)

2.  If the vertical lift has been engaged return chair to it's lowest position using the handset control. 

 

(FIG. 3)

3.   Completely lower the armrests. 

(FIG. 1)

4.   Disconnect the patients safety belt.

5.  Carefully lift the patient's legs and return the footrests to their upright position. 

(FIG. 1)

6.  Using the stand assist grips the patient can now exit the chair.

Transfer of Patient From Chair to Bed

1.  Position the layflat positioned chair as close as possible to the bed or table.

2.   Follow steps to convert chair to layflat postion. 

(SEE PAGE 10)

3.   Using the handset control 

(FIG. 3)

, adjust the height of the layflat positioned chair to match

 

that of the bed or table.

4.   Completely lower the armrest/side-rail on the unloading side of the chair ONLY. 

(FIG. 4)

 

5.  Lock wheels 

(FIG. 2A or 2B)

6.   Transfer patient to bed or table using the appropriate amount of attendants for a safe transfer.

 

(A transfer board or sheet may be used for easier transfer)

FIG. 4

11

Содержание S300 Stretchair

Страница 1: ...PLEASE DO NOT DISCARD THIS MANUAL KEEP FOR FUTURE REFERENCE AND TRAINING S300 Stretchair S550 S750 S999 Bariatric Stretchair OWNER S OPERATING MAINTENANCE MANUAL...

Страница 2: ...D FOR SHIPPING 3 CAREFULLY REMOVE ALL OF THE COMPONENTS FROM THE CARTON 4 SAVE ALL BOXES AND PACKING MATERIAL UNTIL AFTER YOU HAVE ASSEMBLED YOUR PRODUCT AND HAVE VERIFIED THAT ALL COMPONENTS ARE FUNC...

Страница 3: ...rly if it has been dropped or damaged or dropped into water Contact your Winco authorized dealer 5 DO NOT carry or pull this product by power supply cord or use the cord as a handle 6 Keep the cord aw...

Страница 4: ...r transporting in or with ANY type of vehicle or trailer Winco chairs have not been tested or approved for use by an occupant in any type of vehicle or trailer 8 NEVER use the chair arms or backrest a...

Страница 5: ...ropean Union EU health safety environmental requirements Independent U S product safety testing certification by Nationally Recognized Testing Laboratory NRTL Products with the following markings are...

Страница 6: ...air is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Stretchair can help prevent electromagnetic interference by m...

Страница 7: ...ixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked wit...

Страница 8: ...ferential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage...

Страница 9: ...eight 53 5 22 Seat Height 22 28 Seat Width 31 72 Layflat Length 72 22 30 Vertical Lift Chair 22 30 30 38 Vertical Lift Layflat 30 38 303 lbs Chair Weight 312 lbs 750 lbs Weight Capacity 1000 lbs S300...

Страница 10: ...een engaged return chair to it s lowest position and recline the Stretchair slightly using the handset control FIG 3 2 Unlock the wheels and secure the wheels in the steer lock position FIG 2A or 2B 4...

Страница 11: ...using the handset control FIG 3 3 Completely lower the armrests FIG 1 4 Disconnect the patients safety belt 5 Carefully lift the patient s legs and return the footrests to their upright position FIG 1...

Страница 12: ...ting Swing leg for Patient Comfort 1 The Stretchair MUST BE in the upright position 2 Depress the swing leg release handle and adjust to desired elevation FIG 5 Footrests can be pivoted to cushion up...

Страница 13: ...e been locked Adjusting Armrests for Patient Comfort 1 Ensure that the patient s arms are not resting on the armrest prior to adjustment 2 Loosen the armrest knobs FIG 8 BOTH adjustment knobs must be...

Страница 14: ...FIG 10 2 Align the battery guides FIG 11B with battery bracket and slide the battery connectors FIG 11C into the control box 3 Push opposite end of battery in and ensure that the battery release hand...

Страница 15: ...to avoid oil spilliage 6 Carefully unscrew all 4 brass fittings from the Power Unit FIG 19 7 Dispose of the old Power Unit carefully 8 Cut black tubing to remove old ferrule and threaded fitting Cut...

Страница 16: ...nting bolt and spacers FIG 22 6 Remove the lower mounting bolt and spacers FIG 22 7 Carefully remove the old Linak Actuator 8 Position the new Actuator and install the LOWER mounting bolt and spacers...

Страница 17: ...NING INFORMATION VISIT http www wincomfg com permablok info and cleaning instructions MAINTENANCE GUIDE Swing leg Gas Spring Replacement 1 Fully elevate the legrests for easier access to the gas sprin...

Страница 18: ...OUR PRODUCTS Other Quality Winco Furnishings You May Be Interested In Visit us online at www wincomfg com 18...

Страница 19: ...19...

Страница 20: ...ts attached to the frame such as upholstery foam casters mechanisms or related parts that are covered under above warranties Winco Mfg LLC shall not be liable for any labor shipping or any other costs...