Winco PSS30 Скачать руководство пользователя страница 4

Page 2

0210-00

60706-195

TESTING POLICY:

Before any generator is shipped from the factory, it is fully
checked for performance.  The generator is loaded to its full
capacity, and the voltage, current, and frequency are carefully
checked.

Rated output of generators is based on engineering tests of
typical units, and is subject to, and limited by, the temperature,
altitude, fuel, and other conditions specified by the manufacturer
of the applicable engines.

INTRODUCTION AND
DESCRIPTION

With the addition of an Automatic Transfer Switch this packaged
standby system includes all items necessary for a completely
automatic standby power system.

DESCRIPTION

This package power system is designed to automatically provide
standby power to unattended loads during electrical outages.
Upon an interruption of normal electrical service this package
power system's electrical control circuits will automatically start
the engine.  The generator will produce electrical power and the
Automatic Transfer Switch (A.T.S.) will automatically transfer the
electrical loads to the engine-generator set.  Upon restoration of
normal electrical service the A.T.S. will sense return of the normal
commercial power and retransfer the load back to normal
commercial power source. The engine control circuits shut off the
run signal to the engine generator set.

These package power systems consist of two major components:

1) AUTOMATIC TRANSFER SWITCH (UL LISTED)

The Automatic Transfer Switches (A.T.S.) is a wall mount switch
designed for inside installation.   A electronic exerciser circuit is
installed in the A.T.S. as standard equipment.  The A.T.S. also
contains the power failure sensing circuitry necessary to send a
start/stop signal to the engine generator set. The following is a list
of recommended A.T.S. sizes for each model.  Outside switches
as well as additional sizes are available, consult your sales rep
for additional information.

RECOMMENDED

MODEL

VOLTAGE

ATS AMPERAGE

PSS30-3

120/240

200

PSS30-4

120/208

100

PSS30-17

120/240

100

PSS30-18

277/480

100

PSS40-3

120/240

200

PSS40-4

120/208

200

PSS40-17

120/240

200

PSS40-18

277/480

100

Additional optional A.T.S. sizes are available to meet specific
needs.  Contact your local  WINCO dealer or the WINCO Sales
Department for a quote.

2) ENGINE/GENERATOR

PSS30- The engine generator set consists of a GM 3.0L, I-4
Industrial, four cylinder, liquid cooled  engine equipped to run on
L.P./N.G. fuel.  The engine operates at 1800 rpm and frequency
regulation is maintained by the electronic governor within .5
cycles variation, from no load to rated load.  The 30,000 watt
(30kW) generator is a single bearing, direct drive, rotating field
design.  The generator is connected to the engine flywheel via
flexible drive disks.   The engine generator is mounted in a
weather proof enclosure for outside installation.  Connection
boxes are provided to all customer connections (both AC output
and DC control).  A customer supplied 12 Volt, 650 CCA (BCI
group 24) battery is required to complete the installation. Engine
operation is controlled by a Digital Genset Controller (DGC)
mounted in the engine generator enclosure.

PSS40 - The engine generator set consists of a GM 4.3L ,V-6
Industrial,  liquid cooled  engine equipped to run on L.P./N.G.
fuel.  The engine operates at 1800 rpm and frequency regulation
is maintained by the engine governor within .5 cycles variation, no
load to rated load.  The 40,000 watt (40kW) generator is a single
bearing, direct drive, rotating field design.  The generator is
connected to the engine flywheel via flexible drive disks.   The
engine generator is mounted in a weather proof enclosure for
outside installation.  Connection boxes are provided to all
customer connections (both AC output and DC control).  A
customer supplied 12 Volt, 650 CCA (BCI group 24) battery is
required to complete the installation. Engine operation is con-
trolled by a Digital Genset Controller (DGC) mounted in the
engine generator enclosure.

** NOTICE **

These units will automatically transfer if a power outage occurs
while running in an exercise mode.

ENGINE CONTROL MODULE (DGC-2020)

The DGC-2020 Digital Genset Controller provides integrated
engine-genset control, protection, and metering in a single
package. Microprocessor based technology allows for exact
measurement, set point adjustment, and timing functions. Front
panel controls and indicators enable quick and simple DGC-2020
operation. Basler Electric communication software
(BESTCOMSPlus) allows units to be easily customized for each
application. A wide temperature-range liquid crystal display (LCD)
with backlighting can be viewed under a wide range of ambient
light and temperature conditions.

FEATURES
DGC-2020 Digital Genset Controllers have the following features:
• Local and Remote Generator Control
• Engine and Generator Protection
• Programmable Analog Engine Senders
• Programmable Logic
• Automatic Transfer Switch Control (Mains Failure)
• Integrated RS485
• Auto Synchronizing

Содержание PSS30

Страница 1: ...PACKAGE STANDBY SYSTEMS INSTALLATION AND OPERATIONS MANUAL PSS30 B PSS40 E...

Страница 2: ...ned SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the generator and batteries Read and understand all instructions...

Страница 3: ...electrician or contractor The installation must comply with all national state and local codes g Always make sure unit is disabled before placing your hands anywhere near the fan belts alternator or...

Страница 4: ...er liquid cooled engine equipped to run on L P N G fuel The engine operates at 1800 rpm and frequency regulation is maintained by the electronic governor within 5 cycles variation from no load to rate...

Страница 5: ...emperature monitoring over crank protection ECU specific protection elements and diagnostic reporting Metered engine parameters include oil pressure coolant A Liquid Crystal Display The backlit 64 by...

Страница 6: ...setting or resetting the system clock 1 Press K right key for initial set or K left to back up up down to choose menu item and time date element to be changed 2 Press L Edit to access change mode to e...

Страница 7: ...engine s requirements and assist in making you aware of the decisions you must make In no case should the instructions or information provided be interpreted to conflict with any local state or natio...

Страница 8: ...nstalled from the secondary regula tor to the generator set WARNING PERSONAL DANGER Do not use galvanized pipe in fuel line runs The galvanized coating can become eroded and flake off causing possible...

Страница 9: ...performed or supervised only by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When installing or replacing batteries use the proper...

Страница 10: ...e to do so can cause damage to the engine control module in the generator set All connections must be clean and tight Check the electrolyte fluid in the battery periodically to be sure it is above the...

Страница 11: ...t Terminal Block This terminal block is provide for the 120 volt 15 amp feed from customers distrubution panel for the block heater and the trickle charger WARNING A main line circuit breaker has been...

Страница 12: ...will not start and run without either the jumper installed or a remote N C switch installed G Fuel Select Toggle Switch This SWITCH allows you to change the engine from one fuel to the other See Chang...

Страница 13: ...generator terminals in the Automatic Transfer Switch The voltage between the G1 and the G3 terminals should be the same as it was on the generator front panel The voltage should also be checked betwe...

Страница 14: ...3 Governor is defective 4 AC short in generator components ATS PANEL WILL NOT TRANSFER TO EMERGENCY SUPPLY GENERATOR 1 No AC generator output from generator 2 Defective transfer switch controller 3 In...

Страница 15: ...60706 195 Page 13 0210 00 VOLTAGE REGULATOR WIRING THREE PHASE AND SINGLE PHASE...

Страница 16: ...Page 14 0210 00 60706 195 THREE PHASE AC WIRING HIGH AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS...

Страница 17: ...60706 195 Page 15 0210 00 THREE PHASE AC WIRING DELTA SINGLE PHASE AC WIRING SINGLE PHASE 120 240 VOLTS THREE PHASE DELTA 120 240 VOLTS...

Страница 18: ...Page 16 0210 00 60706 195 DC SCHEMATIC...

Страница 19: ...0706 195 Page 17 0210 00 PSS30 OUTLINE DRAWING AND WIRING ENTRANCE PSS40 OUTLINE DRAWING AND WIRING ENTRANCE DIMENSIONS ARE SUBJECT TO CHANGE ALWAYS OBTAIN A CERTIFIED DRAWING FOR CONSTRUCTION PURPOSE...

Страница 20: ...e are limited to 12 months or 1000 hours which ever accurs first from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on t...

Отзывы: