Winco PSS30 Скачать руководство пользователя страница 3

60706-195

Page 1

0210-00

2.

FIRE HAZARD - Natural gas and L.P. present a hazard of
possible explosion and/or fire.

a.

Do not smoke or use open flame near the generator
set.

b.

Keep a fire extinguisher nearby and know its proper use.
Fire extinguishers rated ABC by NFPA are appropriate.

3.

DEADLY EXHAUST GAS - Exhaust fumes from any gaso-
line engine contain carbon monoxide, an invisible, odorless
and deadly gas that must be mixed with fresh air.

a.

Operate only in well ventilated areas.

b.

Never operate indoors.

c.

Never operate the unit in such a way as to allow exhaust
gases to seep back into closed rooms (i.e. through
windows, walls or floors).

4.

NOISE HAZARD - Excessive noise is not only tiring, but
continual exposure can lead to loss of hearing.

a.

Use hearing protection equipment when working
around this equipment for long periods of time.

b.

Keep your neighbors in mind when permanently install-
ing  this equipment.

5.

CLEANLINESS - Keep the generator and surrounding area
clean.

a.

Remove all grease, ice, snow or materials that create
slippery conditions around the unit.

b.

Remove any rags or other material that could create
potential fire hazards.

c.

Carefully wipe up any gas or oil spills before starting the
unit.

d.

Never allow leaves or other flammable material to build
up around the engine exhaust area.

6.

SERVICING EQUIPMENT - All service, including the
installation or replacement of service parts, should be
performed only by a qualified technician.

a.

Use only factory approved repair parts.

b.

Do not work on this equipment when fatigued.

c.

Never remove the protective guards, cover, or recep-
tacle panels while the engine is running.

d.

Use extreme caution when working on electrical compo-
nents.  High output voltages from this equipment can
cause serious injury or death.

e.

Always avoid hot mufflers, exhaust manifolds, and
engine parts.  They all can cause severe burns instantly.

f.

Installing a generator set is not a “do-it-yourself” project.
Consult a qualified, licensed electrician or contractor.
The installation must comply with all national, state, and
local  codes.

g.

Always make sure unit is disabled before placing your
hands anywhere near the fan, belts, alternator or water
hoses.

IMPORTANT SAFETY
INSTRUCTIONS

SAVE THESE INSTRUCTION

This manual contains important instructions that
should be followed during installation and maintenance
of the generator and batteries.

Read and understand all instructions in the manual
before starting and operating the generator set.

This engine generator set has been designed and manufactured
to allow safe, reliable performance.  Poor maintenance, improper
or careless use can result in potential deadly hazards;  from
electrical shock, exhaust gas asphyxiation, or fire.  Please read
all safety instructions carefully before installation or use.  Keep
these instructions handy for future reference.  Take special note
and follow all warnings on the unit labels and in the manuals.

ANSI SAFETY DEFINITIONS

************************************************************

DANGER:

DANGER indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury. This signal word
is to be limited to the most extreme situations.
************************************************************

************************************************************

WARNING:

 WARNING indicates a potentially hazardous situation which, if
not avoided, could result in death or serious injury.
************************************************************

************************************************************

CAUTION:

CAUTION indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also be
used to alert against unsafe practices.
************************************************************

NOTE:

CAUTION is also used on the unit labels and in this manual to
indicate a situation that could result in serious damage or
destruction of the equipment and possible personal injury.

1.

ELECTRIC SHOCK -  The output voltage present in this
equipment can cause a fatal electric shock. This equipment
must be operated by a responsible person.

a.

Do not allow anyone to operate the generator without
proper instruction.

b.

Guard against electric shock.

c.

Avoid contact with live terminals or receptacles.

d.

Use extreme care if operating this unit in rain or snow.

e.

Use only three-prong grounded receptacles and
extension cords.

f.

Be sure the unit is properly grounded to an external
ground rod driven into the earth.

Содержание PSS30

Страница 1: ...PACKAGE STANDBY SYSTEMS INSTALLATION AND OPERATIONS MANUAL PSS30 B PSS40 E...

Страница 2: ...ned SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the generator and batteries Read and understand all instructions...

Страница 3: ...electrician or contractor The installation must comply with all national state and local codes g Always make sure unit is disabled before placing your hands anywhere near the fan belts alternator or...

Страница 4: ...er liquid cooled engine equipped to run on L P N G fuel The engine operates at 1800 rpm and frequency regulation is maintained by the electronic governor within 5 cycles variation from no load to rate...

Страница 5: ...emperature monitoring over crank protection ECU specific protection elements and diagnostic reporting Metered engine parameters include oil pressure coolant A Liquid Crystal Display The backlit 64 by...

Страница 6: ...setting or resetting the system clock 1 Press K right key for initial set or K left to back up up down to choose menu item and time date element to be changed 2 Press L Edit to access change mode to e...

Страница 7: ...engine s requirements and assist in making you aware of the decisions you must make In no case should the instructions or information provided be interpreted to conflict with any local state or natio...

Страница 8: ...nstalled from the secondary regula tor to the generator set WARNING PERSONAL DANGER Do not use galvanized pipe in fuel line runs The galvanized coating can become eroded and flake off causing possible...

Страница 9: ...performed or supervised only by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When installing or replacing batteries use the proper...

Страница 10: ...e to do so can cause damage to the engine control module in the generator set All connections must be clean and tight Check the electrolyte fluid in the battery periodically to be sure it is above the...

Страница 11: ...t Terminal Block This terminal block is provide for the 120 volt 15 amp feed from customers distrubution panel for the block heater and the trickle charger WARNING A main line circuit breaker has been...

Страница 12: ...will not start and run without either the jumper installed or a remote N C switch installed G Fuel Select Toggle Switch This SWITCH allows you to change the engine from one fuel to the other See Chang...

Страница 13: ...generator terminals in the Automatic Transfer Switch The voltage between the G1 and the G3 terminals should be the same as it was on the generator front panel The voltage should also be checked betwe...

Страница 14: ...3 Governor is defective 4 AC short in generator components ATS PANEL WILL NOT TRANSFER TO EMERGENCY SUPPLY GENERATOR 1 No AC generator output from generator 2 Defective transfer switch controller 3 In...

Страница 15: ...60706 195 Page 13 0210 00 VOLTAGE REGULATOR WIRING THREE PHASE AND SINGLE PHASE...

Страница 16: ...Page 14 0210 00 60706 195 THREE PHASE AC WIRING HIGH AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS...

Страница 17: ...60706 195 Page 15 0210 00 THREE PHASE AC WIRING DELTA SINGLE PHASE AC WIRING SINGLE PHASE 120 240 VOLTS THREE PHASE DELTA 120 240 VOLTS...

Страница 18: ...Page 16 0210 00 60706 195 DC SCHEMATIC...

Страница 19: ...0706 195 Page 17 0210 00 PSS30 OUTLINE DRAWING AND WIRING ENTRANCE PSS40 OUTLINE DRAWING AND WIRING ENTRANCE DIMENSIONS ARE SUBJECT TO CHANGE ALWAYS OBTAIN A CERTIFIED DRAWING FOR CONSTRUCTION PURPOSE...

Страница 20: ...e are limited to 12 months or 1000 hours which ever accurs first from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on t...

Отзывы: