background image

24

OPM-124/B

ENGINE GENERATOR SET 

LIMITED WARRANTY

WINCO Inc. has been engineering and manufacturing high quality generators since 1927. WINCO Inc. warrants to the original owner 

that the purchased product is free from defects in materials and/or workmanship for the period of time outlined below. If the product 

should prove defective within the time period outlined below, it will be repaired, adjusted or replaced at the option of WINCO Inc., 

provided that the product, upon inspection by an authorized WINCO Inc. service center, has been found to have been properly installed, 

maintained and operated in accordance with WINCO Inc.’s Installation and Operating Manuals, engine manufacturer installation and 

operation guidelines, and National and local code. This limited warranty is not valid or enforceable unless:

 

 

1. All supporting product maintenance records are kept on file and made available upon request from WINCO Inc. 

 

 

2. A copy of the WINCO Inc. Start-up Completion and Warranty Validation Checklist is properly and completely filled out and 

 

 

  returned to WINCO Inc. within 30 days of start-up. 

 

 

3. The product is routinely exercised in accordance with operating instructions. This warranty does not apply to malfunctions 

 

 

  caused by physical damage, misuse, improper installation, repair or service by unauthorized persons; or normal wear and 

 

 

  tear. The warranty is not assignable.

Standby WINCO Inc. Product  Warranty Period:

 

• Engine generator set: Parts and Labor for two (2) year from the date of factory invoice or 2,000 hours (whichever occurs first).

 

• Accessories (installed on the product or shipped loose): Parts and Labor for one (1) year from the date of factory invoice or 2,000 

 

  hours (whichever occurs first).

The start of the warranty period can be adjusted to the date of unit start-up (limited up to 180 days from invoice date) provided that the 

following information is provided to WINCO Inc. at the time of start-up: 

 

  1. A copy of the WINCO Inc. Start-up Completion and Warranty Validation Checklist is properly and completely filled out and 

 

 

returned to WINCO Inc. within 30 days of start-up. 

 

  2. Some engines may require revalidation after long-term storage. The engine revalidation process if included in the manual must 

  be 

followed.

To obtain warranty service: 

 

Contact your nearest authorized WINCO Inc. service center. For assistance in locating your nearest authorized service center, 

 

contact WINCO Inc.’s Service Department.

Warranty service may be performed by an authorized WINCO Inc. service center only. Service work performed by unauthorized persons 

will void all warranties.

WINCO Inc. shall not be liable for any claim in an amount greater than the purchase price of the product. In no event shall WINCO Inc. 

be held liable for any special, indirect, consequential or liquidated damages.

WINCO Inc. shall not be liable for any claim that requires replacement of engine, part, or component of the product that is no longer 

manufactured or available. Additionally, WINCO Inc. will not be liable for any engine replacement that may require an emissions tier-

level change.

THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE NO OTHER WARRANTIES, EXPRESSED 

OR IMPLIED, OR OTHERWISE CREATED UNDER THE UNIFORM COMMERCIAL CODE, INCLUDING BUT NOT LIMITED TO WARRANTIES 

OF MERCHANTABILITY, OR WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.

The following items and/or circumstances are excluded from this limited warranty:

 

• Engine starting batteries: The battery manufacturers’ warranty applies. Consult your local battery supplier for warranty service. 

 

• Fuel system and/or governing system adjustments performed during or after start-up.

 

• Normal maintenance items: Consumable items such as belts, filters and hoses.

 

• Damage caused by over-loading the generator and failure to adequately provide over-load protection.

 

• LP/NG fuel adjustments or conversion from one fuel to another.

 

• Any repeat or shop come-back repairs resulting from poor service work or improper diagnosis and testing. Replacement of parts 

 

  as a trail-and-error method of diagnosis will not be considered for warranty.

 

• Adjustments and tune–ups performed during start-up or thereafter. 

 

• Loose connections (electrical and mechanical) not found during start-up.

 

• All fluid level related items including low coolant not found during start-up or checked during regular maintenance intervals. 

 

• Equipment modifications made without the written consent of WINCO Inc. will void all warranties.

 

• Shipping damage of any type. All equipment is shipped F.O.B. factory and risk of loss transfers to the carrier once loaded for 

 

  shipment. It is the responsibility of the receiving party to sign for the receipt of, and note any shipping damage to the equipment. 

 

  Freight damage claim filing is the responsibility of the receiving party. In the rare event that damage occurs during shipment, 

 

  WINCO Inc. will not warrant any damage to the unit resulting from packaging material.

 

• Any special access fees, requirements or after hours scheduling to gain access to the equipment for warranty service purposes. 

 

• Rental generators used while warranty work is being performed.

 

• Damages caused by acts of nature, such as lightning, wind, flood, wild fires, or earthquake.

 

• Any damage due to situations beyond the control of the manufacturing and/or workmanship of the product. 

 

• Use of non-protected steel enclosure within 25 miles of the coast.

 

• Damage caused by improper installation or failure to provide adequate ventilation.

 

• Misapplication of the equipment such as usage outside the original design parameters as stated on the nameplate of the 

   equipment. 

 

• Equipment purchased at the standby rating that is being used in a prime power application(s).

 

• Diesel engine “Wet Stacking” due to lightly loaded diesel engines.

 

• Travel time or service calls unless given written authorization by WINCO Inc.

WINCO INC. • 225 S. CORDOVA AVE • LE CENTER, MN  56057 • 507-357-6821

Содержание PSS150-17

Страница 1: ...contact us on this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DATE...

Страница 2: ...contains important instructions that should be followed during installation and maintenance of the generator Read and understand all instructions in the manual before starting and operating the gener...

Страница 3: ...mixed with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back into close...

Страница 4: ...em 12 Volt Muffler Standard Fuel Consumption full load LP NG 19 83 GAL HR 1 832 410 BTU HR 2 014 FT HR 2 014 300 BTU HR CAUTION EQUIPMENT DAMAGE The adjustable breaker has an Instant Trip that must be...

Страница 5: ...a 3 second start delay and a 15 second transfer delay to allow the engine to warm up before transferring the load to the generator When the line power is restored the ATS has a 5 minute transfer dela...

Страница 6: ...laim If you sign for the unit the transfer of the ownership requires that you file the freight claim 2 Before proceeding with the preparations of your new generator for operation take a couple of minu...

Страница 7: ...ovided be interpreted to conflict with any local state or national codes If in doubt always consult your local fire marshal gas supplier or building inspector WARNING FIRE HAZARD All fuel runs should...

Страница 8: ...voir If this is not done the demand regulator on the unit and the pressure regulator in the fuel line will interfere with each other This regulator must be sized to accommodate the demand of the gener...

Страница 9: ...mall rocker switch has been provide on the underside of the engine control cabinet for this purpose Opening the rocker switch will tell the ECU mounted on the engine that you are operating on NG Fuel...

Страница 10: ...to the skin and eyes It is electrically conductive and corrosive The following precautions must always be taken 1 Always wear full eye protection and protective clothing 2 Where electrolyte contacts...

Страница 11: ...without over charging them During this stage the green LED is constantly lit There are optional 5 and 10 amp chargers available that may be installed on some units The block heater is thermostatically...

Страница 12: ...2 37 1 2 803 5 3 9 1 7 11 50 1 25 2 1 1 2 3 03 2 2 29 5 16 250 5 0 7 51 66 75 0 7 6 817 75 3 366 1 335 7 7 66 0 7 7 7 5 1 02 3 57 7 6 5 1 217 16 35235 7 5 1 250 7 21 21 1 72 1 2 81 87 25 86 6 352 7 0...

Страница 13: ...ntrance rated This will allow you to test the generator under load Should you ever have to work on the switch you will be able to disconnect the power and work on the switch cold without having the po...

Страница 14: ...art relay is closed again B ESTOP ESTOP Remote Emergency Stop terminals These two terminals are shipped with a jumper installed If your application requires the installation of a Remote Emergency Stop...

Страница 15: ...T UP WARNING EQUIPMENT DAMAGE Before attempting to start this unit complete your pre start checklist and ensure the generator mainline circuit breaker is in the proper position prior to starting Start...

Страница 16: ...ICE If for any reason during the check out procedure the voltage and frequency are not correct depress the STOP RESET button and correct the trouble before proceeding 4 Stopping There are two ways to...

Страница 17: ...to increase dampening effect 4 LINK POWER RESPONSE A B 550kW Fast B C 100 550kW Fast A C 100kW Fast B D 100kW Slow 5 UFRO Under Frequency Roll Off Clockwise decreases KNEE point 6 SWITCH Select alter...

Страница 18: ...ty air cleaner filter 7 Defective fuel solenoid valve 8 Low Voltage from battery to fuel solenoid must hold 12 Volts during cranking 9 Defective fuel regulator 10 Defective starter fuel solenoid relay...

Страница 19: ...r that all power has been disconnected AUTOMATIC TRANSFER SWITCH Clean and inspect the switch once a year De energize all power sources both line and engine generator set then brush and vacuum away an...

Страница 20: ...C WIRING HIGH AND LOW WYE THREE PHASE L 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS 24 5060 00 60708 165 REE PHASE AC WIRING H AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS SE HIGH WYE TS 3 PH HI...

Страница 21: ...21 OPM 124 B THREE PHASE DELTA 120 240 VOLTS WIRING DELTA LE PHASE 40 VOLTS 4 LEAD 3 PH DELTA 120 240V 12 LEAD 1 PH 120 240V DOUBLE DELTA...

Страница 22: ...22 OPM 124 B ENGINE HARNESS SCHEMATIC...

Страница 23: ...1 1 77 77 1 5 7 50 1 2 6 211 725 211 725 66 86 86 86 86 86 36 1 2 8 1387 20021 6 5 1 1 6 5 1 1 1 1 1 36 32 5 6 7 66 0 5 1 6723 6 7 66 8 6 7 21 6 7 9 5 92 7 8670 17 5 267 7 9 5 1 855 17 66 7 50 1 2 803...

Страница 24: ...quires replacement of engine part or component of the product that is no longer manufactured or available Additionally WINCO Inc will not be liable for any engine replacement that may require an emiss...

Отзывы: