load, such as an air compressor, it will require more 
starting current.  If it is connected to a light load, 
or no load such as a power saw, it will require less 
starting current.  The exact requirement will also 
vary with the brand or design of the motor.

Self-exciting generators respond to severe overload-
ing differently than utility power.  When overloaded, 
the engine is not able to supply enough power to 
bring the electric motor up to operating speed.  The 
generator responds with high initial starting current, 
but the engine speed drops sharply.  The overload 
may stall the engine.  If allowed to operate at very 
low speeds, the electric motor starting winding will 
burn out in a short time.  The generator winding 
might also be damaged.

CAUTION:  EQUIPMENT DAMAGE

 

RUNNING THE GENERATOR SET UNDER 

THESE CONDITIONS MAY RESULT IN DAMAGE 
TO THE GENERATOR STATOR AS WELL AS THE 
MOTOR WINDING.

The heavy surge of current required for starting 
motors is required for only an instant.  The genera-
tor will not be damaged if it can bring the motor up 
to speed in a few seconds of time.  If diffi culty is 
experienced in starting motors, turn all other electri-
cal loads off and if possible reduce the load on the 
electric motor.

PREPARING THE UNIT

UNPACKING

CAUTION:  EQUIPMENT DAMAGE

    THIS UNIT HAS BEEN SHIPPED WITHOUT OIL.  
Failure to maintain the engine oil at the proper level 
will result in serious engine damage.

When you unpack your new engine-generator set be  
sure to remove all the information sheets and manu-
als from the carton.

1.  This generator-set was in good order when 
shipped.  Inspect the generator-set promptly after 
receiving it.  If any damage is noted, notify the trans-
portation company immediately; request proper pro-
cedures for fi ling a “concealed damage” claim.  Title 
to the equipment and responsibility for fi ling a claim 

rests with you when a generator set is sent F.O.B. 
shipping point.  Only you can legally fi le a claim.

2.  Before proceeding with the preparations of your 
new generator set for operation, take a couple of 
minutes to ensure the unit you have received is the 
correct model and review the specifi cation pages in 
this manual to insure that this unit meets your job 
requirements.

LUBRICATION

Before starting the engine, fi ll the crankcase to the 
proper level with a good quality oil.  The recom-
mended grade of oil and quantity of oil required is 
listed in the engine operator’s manual and below in 
this manual.  This unit was shipped with most of the 
oil removed.  The engine normally holds 38 to 39 
ounces of oil.  Since there is some trapped oil in the 
engine, when fi lling the crankcase the fi rst time use 
the dipstick to ensure that you do not over fi ll the 
crankcase. The blow-up shows the full oil level mark 
on the dipstick.  

Oil is added to the engine by removing the oil fi ll cap 
and adding oil at this point.  After fi lling the crank-
case to the proper level, be sure you properly tighten 
the oil fi ll cap.  NOTE:  This engine generator must 
be on a level surface before you check or add oil to 
the system.
The necessity of using the correct oil, and keeping 
the crankcase full cannot be overemphasized.  En-
gine failures resulting from inadequate or improper 
lubricant are considered abuse and not covered by 
the generator or engine manufacturer’s warranty.

Oil Recommendations

Outdoor temperatures determine the proper oil 
viscosity for the engines. Use the chart to select the 
best viscosity for the outdoor temperature range 
expected.

UPPER LIMIT

OIL FILLER CAP/DIPSTICK

LOWER LIMIT

OIL FILL HOLE
(bottom edge)

Содержание Home power HPS6000HE

Страница 1: ...INSTALLATION AND OPERATORS MANUAL HPS6000HE I BI FUEL GENERATOR...

Страница 2: ...ion 8 INITIAL START UP Basic Operation 9 Manual Starting Gasoline only 9 Electric Starting Gasoline 10 Electric Starting NG 11 Stopping Storage 11 Operating Speed 12 CONNECTING THE LOADS 12 Wiring 13...

Страница 3: ...dren c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate e Store fuel on...

Страница 4: ...making enclosures for generators that have been properly engineered The use of these 3rd party enclosures is acceptable as long as they have been certified and meet current code DO NOT attempt to ope...

Страница 5: ...otify the trans portation company immediately request proper pro cedures for filing a concealed damage claim Title to the equipment and responsibility for filing a claim rests with you when a generato...

Страница 6: ...upplier The fuel source should be as close as possible to the outdoor operating location This will reduce the installation cost of fuel runs Connect the fuel supply line to the inlet of the fuel deman...

Страница 7: ...te Length of Fuel Line Fuel Line Size less than 50 feet 3 4 inch black pipe 50 to 200 feet 1 inch black pipe Allow an additional 3 feet for each standard elbow Do not use street ells restrictive Consu...

Страница 8: ...he unit If you intend to use the power plant s electric start system required when using NG you will need to purchase and install a battery to operate it Units equipped with a recoil or rope start wil...

Страница 9: ...de the engine If the oil level drops below a certain point the low oil module on the engine will shut it down This low oil warning system will automatically stop the engine before the oil level reache...

Страница 10: ...the fuel supply by moving the fuel lever to the ON position 3 Move the choke lever to the CLOSED position To restart a warm engine leave the choke lever in the OPEN position 4 Turn the engine switch...

Страница 11: ...mer blended gasoline Using gasoline left over from winter may cause the unit to vapor lock STOPPING AND STORAGE 1 Move the engine switch to the OFF position 2 Turn off the fuel supply valve 3 Before e...

Страница 12: ...oltmeter and a frequency meter or tachometer and be sure the voltage and speed are correct Lower voltage may damage both the generator and any load connected to it Running the engine at ex cessively h...

Страница 13: ...receptacle on these units are designed to power both 120 or 240 volt loads The plug for this receptacle can be wired for either 120 volt 240 volt or a combination of 120 and 240 volt loads depending...

Страница 14: ...nually or every 100 hours Service more often under dusty conditions WARNING EQUIPMENT DAMAGE Never start or run the engine with the air filter re moved a Remove the wing nut from the air cleaner cover...

Страница 15: ...alified electrical service technician USE ONLY FACTORY APPROVED REPAIR PARTS a Bearing The bearing used in these generators is a heavy duty double sealed ball bearing They require no maintenance or lu...

Страница 16: ...o output voltage Short in load disconnect Tripped or defective circuit breaker Broken or loose wire Defective receptacle No residual magnetism in generator Defective stator Defective rotor field Short...

Страница 17: ...17 3180 10 60706 238 WIRING DIAGRAM...

Страница 18: ...rn the product within 24 months from the date of purchase transportation charges prepaid to your nearest WINCO Authorized Service Center or to WINCO Inc at Le Center Minnesota THERE IS NO OTHER EXPRES...

Страница 19: ...RER S WARRANTY COVERAGE The evaporative emission control system is warranted for two years If any evaporative emission related parts on your equipment are defective the parts will be repaired or repla...

Страница 20: ...3180 10 20 60706 238 WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com...

Отзывы: