BATTERY INSTALLATION

This engine-generator set is shipped with a battery tie down 

kit for customer installation. This kit consists of a battery 

tie down and hardware for installation of the customer 

supplied battery to operate it.

This engine-generator set is designed for electric start only, 

you will need to purchase and install a battery to operate it. 

A 12 Volt battery, BCI group U1 rated at 300 CCA or larger 

is recommended for this electric start engine-generator set. 

Follow the battery manufacturers recommendations for 

servicing and charging prior to use. Connect the battery to 

the electric start system using the cables provided.

CAUTION: EQUIPMENT DAMAGE

These electric start engines are NEGATIVE GROUND. 

Use extreme caution when connecting the battery. 

Connect the Negative battery terminal to GROUND. 

Connecting the positive battery terminal to ground 

will damage the engines charging circuit.

For your safety, always connect the positive battery cable to 

the ‘bat+’ terminal first. .Then connect the negative battery 

cable to the ‘bat-’ terminal. Make sure all connections are 

clean and tight. Reverse the sequence when disconnecting, 

disconnect the negative cable first. The engines produce 

enough direct current to keep the battery charged under 

normal operating conditions, but were not intended to be 

used as a battery charger.

WARNING: PERSONAL INJURY

Lead acid batteries produce explosive hydrogen gas 

when charging. Keep sparks, flames, and burning ciga-

rettes away from the battery. Ventilate the area when 

charging or using the battery in an enclosed space. 

Lead acid batteries contain sulfuric acid, which caus-

es burns. If acid contacts eyes, skin, or clothing, flush 

well with water. For contact with eyes, get immediate 

medical attention.

BATTERY CHARGING

Units equipped with electric start have a small flywheel 

charger built into the engine flywheel assembly for 

recharging the start battery. This flywheel charger 

generates a small AC current that passes through a diode 

assembly to produce a DC charging current of about 1 to 

3 AMPS. This circuit is not designed to be used as a battery 

charging circuit to recharge dead batteries.

Содержание Home power HPS12000HE

Страница 1: ...ould ever need to contact us on this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _______________________________________...

Страница 2: ...N CANISTER GENERATOR CARE 18 EXERCISING THE GENERATOR GENERATOR MAINTENANCE CLEANING TROUBLESHOOTING 18 RECEPTACLE WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCT...

Страница 3: ...Amps 72 36 GENERATOR Generator Manufacturer Mecc Alte Spa Generator Model Number S20FS 160 A Part Number 351836 1 Rotor Resistance 6 57 Ohms Stator Resistance 0 124 Ohms Cap Winding Resistance 0 60 O...

Страница 4: ...the earth 2 FIRE HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C...

Страница 5: ...te performance these units should never be run in small compartments without positive fresh air flow RESTRICTED USES DO NOT remove from the cradle assembly Removal of the generator from the cradle ass...

Страница 6: ...al horsepower motors take about the same amount of current to run them whether they are Repulsion Induction RI Capacitor Cap or Split Phase SP type If the electric motor is connected to a hard startin...

Страница 7: ...with the recommended oil to the upper limit mark on the oil level dipstick Running the engine with a low oil level can cause engine damage This type of damage is not covered by the Distributor s Limit...

Страница 8: ...d flake off causing possible obstruction or damage to the reg ulator or fuel valve The obstruction could cause an inoperative engine or an explosive fuel leak NATURAL GAS Correct fuel pressure cannot...

Страница 9: ...rams above are system parts supplied by customer Reference number 4 is the engine generator set Below is a table of the fuel pressure reading at each reference in the system Fuel Pressure Table Single...

Страница 10: ...came with instructions and parts list After installing the dolly kit keep instructions and parts list for future reference OPTIONAL FUEL SOLENOID KIT An optional 12 Volt DC fuel solenoid kit is availa...

Страница 11: ...e to the bat terminal first Then connect the negative battery cable to the bat terminal Make sure all connections are clean and tight Reverse the sequence when disconnecting disconnect the negative ca...

Страница 12: ...proved by using shorter starting cycles with time to cool off between cranking cycles Do not operate the starter more than 5 seconds and wait at least 10 seconds before operating the starter again 7 6...

Страница 13: ...ment plugged into the unit and possi ble injury to the individual All engines have a tendency to slow down when a load is applied When the electrical load is connected to the generator the engine is m...

Страница 14: ...GENERATORS This WINCO portable generator ships with a bonded neutral and overcurrent protection NFPA 70 refers to this as a separately derived system When connecting it to a building a transfer switch...

Страница 15: ...nameplate on your generator for the amperage capabilities of your unit CAUTION EQUIPMENT DAMAGE Failure to properly limit and balance the load applied to the generator will cause the generator to prod...

Страница 16: ...l can damage paint and some types of plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not covered under the Distributor s Limited Warranty Gasoline is...

Страница 17: ...ET AIR CLEANER COVER LATCH AIR CLEANER CASE PACKING FOAM FILTER ELEMENT PAPER FILTER ELEMENT AIR CLEANER COVER WING NUT AIR CHAMBER 9 Operating the engine without an air filter or with a damaged air f...

Страница 18: ...perly should it be needed in an emergency GENERATOR MAINTENANCE Any major generator service including the installation or replacement of parts should be performed only by a qualified electrical servic...

Страница 19: ...19 60706 236 J 17 13240 11 60706 236 CONTROL PANEL WIRING DIAGRAM RECEPTACLE WIRING DIAGRAM...

Страница 20: ...quest THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED OR OTHERWISE CREATED INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILI...

Отзывы: