background image

3

OPM-134/B

WARNING: FIRE HAZARD

Gasoline and other fuels present a hazard of possible 

explosion and/or fire.

 

A. Do not refuel when the engine is running or hot.

 

B. Keep fuel containers out of reach of children.

 

C. Do not smoke or use open flame near the 

      generator set or fuel tank.

 

D. Keep a fire extinguisher nearby and know its 

      proper use. Fire extinguishers rated ABC by 

   NFPA 

are 

appropriate.

 

E. Store fuel only in an approved container, and 

      only in a well ventilated area.

 

F. Follow local codes for closeness to combustible 

   material.

CAUTION: PERSONAL INJURY

The muffler becomes very hot during operation and 

for a period after the unit has been turned off. Do not 

touch the muffler until it has completely cooled off.

CAUTION: NOISE HAZARD

Excessive noise is not only tiring, but continual 

exposure can lead to loss of hearing.

 

A. Use hearing protection when working around 

      this equipment for long periods of time.

 

B. Keep your neighbors in mind when using this 

   equipment.

CAUTION

Keep the generator and surrounding area clean.

 

A. Remove all grease, ice, snow or materials that 

   create 

      slippery conditions around the unit.

 

B. Remove any rags or other materials that could 

      create a potential fire hazard.

 

C. Carefully clean up any gas or oil spills before 

   starting 

the 

unit.

CAUTION

All service, including the installation or replacement of 

service parts, should be performed only by a qualified 

technician.

 

A. Use only factory approved repair parts.

 

B. Do not work on this equipment when fatigued.

 

C. Never remove the protective guards, covers, or 

      receptacle panels while the engine is running.

 

D. Use extreme caution when working on electrical 

      components. High output voltage from this 

      equipment can cause serious injury or death.

 

E. Always avoid hot mufflers, exhaust manifolds, 

      and engine parts. They can cause severe burns 

   instantly.

 

F. The use of the engine-generator set must comply 

      with all national, state, and local codes.

SAFETY INFORMATION

This engine generator set has been designed and 

manufactured to allow safe, reliable performance. Poor 

maintenance, improper or careless use can result in 

potentially deadly hazards; from electrical shock, exhaust 

gas asphyxiation, or fire. Please read all safety instructions 

carefully before installation or use. Keep these instructions 

handy for future reference. Take special note and follow all 

warnings on the unit labels and in the manuals.

SAFETY DEFINITIONS

DANGER

Indicates an imminently hazardous situation 

which, if not avoided, will result in death or 

serious injury. 

WARNING

Indicates a potentially hazardous situation 

which, if not avoided, could result in death 

or serious injury.

CAUTION

Indicates a potentially hazardous situation 

which, if not avoided, may result in minor or 

moderate injury. It may also be used to alert 

against unsafe practices.

CALIFORNIA PROPOSITION 65

WARNING: This product contains crude oil, 

gasoline, diesel fuel and other petroleum 

products, Antifreeze to which can expose you 

to chemicals including toluene and benzene, 

Ethylene glycol (ingested) which are known to the 

State of California to cause cancer, birth defects or other 

reproductive harm and developmental issues. 

For more information go to www.P65Warning.ca.gov.

DANGER: ELECTRICAL SHOCK 

The output voltage present in this equipment can cause 

fatal electric shock. This equipment must be operated 

by a responsible person.

 

A. Do not allow anyone to operate the generator 

   without 

proper 

instruction.

 

B. Guard against electric shock.

 

C. Avoid contact with live terminals or receptacles.

 

D. Use extreme care if operating this unit in rain or 

   snow.

 

E. Use only three-pronged grounded receptacles 

   and 

extension 

cords.

 

F. Be sure the unit is properly grounded for your 

   application.

DANGER: DEADLY EXHAUST GAS

Exhaust fumes from any gasoline engine contain 

carbon monoxide, an invisible, odorless and deadly gas 

that must be mixed with fresh air.

 

A. Operate only in well ventilated areas.

 

B. Never operate indoors including attached 

   garages

 

C. Never operate the unit in such a way as to allow 

      exhaust gases to seep back into closed rooms 

      (i.e. through windows, walls, floors).

Содержание DR45F4/1

Страница 1: ...help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DATE __________________________________...

Страница 2: ...MANUAL Congratulations on your choice of a WINCO generator You have selected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best...

Страница 3: ...ne generator set has been designed and manufactured to allow safe reliable performance Poor maintenance improper or careless use can result in potentially deadly hazards from electrical shock exhaust...

Страница 4: ...1D or 2D EN590 or equivalent Oil Type SEE LUBRICATION SECTION Oil Capacity 8 98 Quarts Cooling System 50 50 mix DR65F4 Generator Wattage 62 000 62 000 62 000 62 000 Volts 120 240 120 208 120 240 277...

Страница 5: ...wage nameplate on your generator before selecting the correct information below Model Stamford UCI274C Winding Group 311 Resistances Rotor 1 34 Ohms 22 C Stator 0 0317 Ohms Per Ph 22 C Exciter Rotor 0...

Страница 6: ...emperature altitude fuel and other conditions specified by the manufacturer of applicable engines This unit comes factory set for either key start or manual start With the DSE 7310 MKII controller use...

Страница 7: ...own brackets hardware d Unit components or accessory items shipped loose for on site installation e Optional accessories 3 Remove main frame hold down bolts 4 Unit can now be lifted from shipping rail...

Страница 8: ...the ATS to protect the contacts ENGINE GENERATOR SET MOUNTING The unit s main frame must be bolted solidly to a solid base The engine generator is mounted on channels which are attached with special...

Страница 9: ...install an additional lift pump to bring the fuel up to the mechanical fuel pump on the engine The information in this manual is offered to assist you in providing the proper fuel for your engine How...

Страница 10: ...ce SERVICING BATTERIES CAUTION EQUIPMENT DAMAGE Voltage spikes can damage the DC control circuits Disconnect the battery charger from the AC power source prior to disconnecting the battery Batteries u...

Страница 11: ...hour meter and the service entrance providing the service entrance ampere rating is within the transfer switch s rated capability If only specific circuits are to be powered under emergency power fail...

Страница 12: ...re sizing based on both wire type and amperage For additional information on wire sizes refer to table 310 16 of the National Electrical Code ANSI NFPA 70 C GROUND LUG These ground lugs are bonded to...

Страница 13: ...t to do contact a competent professional to assist you The NFPA 70 250 34 35 are good technical references PERMANENTLY INSTALLED GENERATORS This WINCO portable generator ships with a bonded neutral an...

Страница 14: ...ng to ensure they function properly SERIAL COMMUNICATION DSE provides a series of remote accessories that can help provide useful information to operators These accessories communicate over the DSE Ne...

Страница 15: ...SCO 300 UL SWITCH When Normal Source Fails Terminals On Transfer Switch Contact Closes TB1 and TB2 Contact Opens TB1 and TB3 Engine start and auxiliary circuit terminal block TB located on 3ATS 3NTS t...

Страница 16: ...d possible serious injury Always inspect unit prior to operation CAUTION For the first 10 seconds of operation all of the oil coolant and electrical shutdowns are disabled This is enough time to cause...

Страница 17: ...unit complete your pre start checklist and ensure the generator mainline circuit breaker is in the proper position prior to starting Starting this unit without it properly connected can cause serious...

Страница 18: ...TOP RESET button will stop the unit immediately Pressing the AUTO mode button will stop the unit but only after the cool down timers have timed out and there is no remote start signal being sent to th...

Страница 19: ...filler port using lubricant oil with the suitable oil table in the LUBRICATION section of this manual 6 Use the dip stick to ensure the level of oil does not exceed the MAX limit 7 Insert the dipstic...

Страница 20: ...t until it has emptied completely When empty repair the circuit making sure that the sleeves are Filter perfectly sealed 2 Refill the engine and the heat exchanger until complete top off 3 With the fi...

Страница 21: ...the injection system when the engine is expected to be inoperative for periods of more than two months the following operations must be carried out in preparation for this 1 Drain the lubricant from...

Страница 22: ...Hours Change Oil Filters 600 Hours Change Fuel Filters 600 Hours Change Fuel Pre Filter 600 Hours Check Exhaust System for Damage 6 Months Clean Fuel Tank 6 Months Change Auxiliary Member Belt 1200 Ho...

Страница 23: ...fective fuel solenoid Defective engine harness Improper battery voltage to fuel pump or fuel solenoid Engine starts then stops and alarm light comes on Engine oil pressure is low Engine has high water...

Страница 24: ...750 8 6 4 3 2 1 1 0 2 0 3 0 4 0 250 300 350 400 500 600 700 750 800 900 1000 1250 1500 1750 2000 40 50 65 75 90 100 120 135 155 180 205 230 250 270 310 340 375 385 395 425 445 485 520 545 560 45 55 7...

Страница 25: ...5 2 35 6685 6 1 5 22 17 7 03 6 1 5 8 62 12 6 0 67 57 5 7 7 51 725 3 27 5 67 57 62 12 2 22 17 02 8 8 7 7 21 0 1 1 51 66 211 725 27 2 35 6685 1 22 17 7 03 5 785 1 6 1 56 25 6 7 6 5 9 6 216 5 9 51 6 5 3...

Страница 26: ...57 67 57 1 1 77 77 1 5 7 50 1 2 6 211 725 211 725 66 86 86 86 86 86 36 1 2 8 1387 20021 6 5 1 1 6 5 1 1 1 1 1 36 32 5 6 7 66 0 5 1 6723 6 7 66 8 6 7 21 6 7 9 5 92 7 8670 17 5 267 7 9 5 1 855 17 66 7...

Страница 27: ...08 165 HIGH AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS THREE PHASE HIGH WYE 277 480V THREE PHASE LOW WYE 120 208V THREE PHASE DELTA 120 240 VOLTS THREE PHASE AC W...

Страница 28: ...damages WINCO Inc shall not be liable for any claim that requires replacement of engine part or component of the product that is no longer manufactured or available Additionally WINCO Inc will not be...

Отзывы: