E. Store fuel only in an approved container, and only in 

 

  a well ventilated area.

 

F. Follow local codes for closeness to combustible 

   material.

3. DEADLY EXHAUST GAS - 

Exhaust fumes from any internal combustion engine 

contain carbon monoxide, an invisible, odorless and deadly 

gas that must be mixed with fresh air.

 

A. Operate only in well ventilated areas.

 

B. Never operate indoors including attached garages

 

C. Never operate the unit in such a way as to allow 

 

  exhaust gases to seep back into closed rooms (i.e. 

 

  through windows, walls, floors).

4. NOISE HAZARD - 

Excessive noise is not only tiring, but continual exposure 

can lead to loss of hearing.

 

A. Use hearing protection when working around this  

 

  equipment for long periods of time.

 

B. Keep your neighbors in mind when using this 

   equipment.

5. CLEANLINESS - 

Keep the generator and surrounding area clean.

 

A. Remove all grease, ice, snow or materials that create 

 

  slippery conditions around the unit.

 

B. Remove any rags or other materials that could create 

 

  a  potential fire hazard.

 

C. Carefully clean up any gas or oil spills before starting 

 

  the unit.

6. SERVICING EQUIPMENT -

All service, including the installation or replacement of 

service parts, should be performed only by a qualified 

technician.

 

A. Use only factory approved repair parts.

 

B. Do not work on this equipment when fatigued.

 

C. Never remove the protective guards, covers, or 

 

  receptacle panels while the engine is running.

 

D. Use extreme caution when working on electrical 

 

  components. High output voltage from this 

 

  equipment can cause serious injury or death.

 

E. Always avoid hot mufflers, exhaust manifolds, and 

 

  engine parts. They can cause severe burns instantly.

 

F. The use of the engine-generator set must comply 

 

  with all national, state, and local codes.

SAFETY INFORMATION

This engine generator set has been designed and 

manufactured to allow safe, reliable performance. Poor 

maintenance, improper or careless use can result in 

potentially deadly hazards; from electrical shock, exhaust 

gas asphyxiation, or fire. Please read all safety instructions 

carefully before installation or use. Keep these instructions 

handy for future reference. Take special note and follow all 

warnings on the unit labels and in the manuals.

CALIFORNIA PROPOSITION 65

WARNING: This product contains crude oil, 

gasoline, diesel fuel and other petroleum 

products, Antifreeze to which can expose you 

to chemicals including toluene and benzene, 

Ethylene glycol (ingested) which are known to 

the State of California to cause cancer, birth defects or other 

reproductive harm and developmental issues. 

For more information go to www.P65Warning.ca.gov.

ANSI SAFETY DEFINITIONS

DANGER:

DANGER indicates an imminently hazardous situation 

which, if not avoided, will result in death or serious injury. 

This signal word is to be limited to the most extreme 

situations.

WARNING:

WARNING indicates a potentially hazardous situation 

which, if not avoided, could result in death or serious injury.

CAUTION:

CAUTION indicates a potentially hazardous situation which, 

if not avoided, may result in minor or moderate injury. It 

may also be used to alert against unsafe practices.

1. ELECTRICAL SHOCK -

The output voltage present in this equipment can cause 

fatal electric shock. This equipment must be operated by a 

responsible person.

 

A. Do not allow anyone to operate the generator 

 

  without proper instruction.

 

B. Guard against electric shock.

 

C. Avoid contact with live terminals or receptacles.

 

D. Use extreme care if operating this unit in rain or 

   snow.

 

E. Use only three-pronged grounded receptacles and 

 

  extension cords.

 

F. Be sure the unit is properly grounded to an external 

 

  ground rod driven into the earth.

2. FIRE HAZARD - 

Gasoline and other fuels present a hazard of possible 

explosion and/or fire.

 

 

A. Do not refuel when the engine is running or hot.

 

B. Keep fuel containers out of reach of children.

 C. 

Do not smoke or use open flame near the generator 

 

  set or fuel tank.

 

D. Keep a fire extinguisher nearby and know its proper 

 

  use. Fire extinguishers rated ABC by NFPA are 

   appropriate.

Содержание DP5000-03/A

Страница 1: ...E No other WINCO generator has the same serial number as yours If you should ever need to contact us on this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DATE _________________________________________ DEALER NAME ___________________________________________ DEALER PHONE ...

Страница 2: ...R GENERATOR MAINTENANCE CLEANING TROUBLESHOOTING 14 RECEPTACLE WIRING DIAGRAM 15 36 MONTH LIMITED WARRANTY 16 CA EMISSION CONTROL WARRANTY 16 SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the generator Read and understand all instructions in the manual before starting and operating the generator USING THIS MANUAL ...

Страница 3: ...mber 16346 612 ENGINE Engine Manufacturer Honda Engine Model Number GX270 Type RT2VMT2 Code GCBGT Oil Capacity 38 4 oz 1 2 qts TESTING POLICY Before any generator is shipped from the factory it is fully checked for performance The generator is loaded to its full capacity and the voltage current and frequency are carefully checked Rated output of generator is based on engineering tests of typical u...

Страница 4: ...can result in potentially deadly hazards from electrical shock exhaust gas asphyxiation or fire Please read all safety instructions carefully before installation or use Keep these instructions handy for future reference Take special note and follow all warnings on the unit labels and in the manuals CALIFORNIA PROPOSITION 65 WARNING This product contains crude oil gasoline diesel fuel and other pet...

Страница 5: ...s can be drawn from the receptacles attached to either A or B output legs This generator is capable of producing 37 5 Amps of 240 volt current at C Check the appliance or tool nameplates for the current and voltage to insure compatibility Remember that power taken from C reduces the power available equally at both A and B and vice versa STARTING ELECTRIC MOTORS Electric motors require much more cu...

Страница 6: ...s been out of operation for an extended period of time it is best to drain old fuel from the engine and replace with fresh fuel before attempting to start See the engine manual for special instruction for operating this unit at over 5000 feet PREPARING THE UNIT UNPACKING CAUTION EQUIPMENT DAMAGE THIS UNIT HAS BEEN SHIPPED WITH OIL Failure to maintain the engine oil at the proper level will result ...

Страница 7: ...be at the full mark before the engine will start and run BASIC OPERATION 1 Check oil level refill as needed 2 Move the fuel valve lever to the ON position 3 To Start a cold engine move the choke rod to the CLOSED position 4 Move the throttle lever away from the MIN position about 1 3 of the way toward the MAX position 5 Turn the engine switch to the ON position 6 Operate the starter This engine is...

Страница 8: ...ither the receptacles or the generator The generator is a limited source of electrical power therefore pay special attention to the receptacle and generator ratings The nameplate rating can be obtained through a single receptacle as long as the receptacles amperage rating is not exceeded CAUTION EQUIPMENT DAMAGE Never permit the choke to remain on after the engine has run for a short time It is no...

Страница 9: ...PERSONAL DANGER A fully isolated double pole double throw manual transfer switch must be installed any time a generator is being connected to an existing distribution system 1 These engine generator sets are designed for portable heavy duty commercial use Receptacles are provided on the control panel to permit 120 and 240 Volt portable appliances and tools to be plugged directly into them A 4 wire...

Страница 10: ...ad This will ensure the generator is balanced Balanced Unbalanced YOURGEN The WINCO YourGen meter allows you to see useful information about your generator from the front panel by displaying RPMs Voltage frequency load hours and maintenance reminders It also has the ability to display warnings if any parameter gets outside of normal operation range Cycle Button During normal operation the display ...

Страница 11: ...equire more frequent oil changes Alarms The display will start blinking and toggle to the first parameter that is out of specification The panel will remain flashing until the fault condition returns to within the acceptable range see following table Acceptable Range Frequency 57 63 Hz Voltage 110VAC 130VAC VAC1 VAC2 220VAC 260VAC Battery When the unit is off the YourGen meter will display the hou...

Страница 12: ...ded service period Service more often under dusty conditions WARNING EQUIPMENT DAMAGE Never start or run the engine with the air filter removed This will allow dirt to enter the engine causing rapid engine wear This type of damage is not covered under warranty 1 Unsnap the air cleaner cover clips remove the air cleaner cover and remove the air filter element ENGINE CARE MAINTENANCE SCHEDULE If maj...

Страница 13: ...ld be operated every three to four weeks It should be operated for a period of time sufficient to warm the unit up and to dry out any moisture that has accumulated in the windings If left this moisture can cause corrosion in the winding Frequent operation of the engine generator set will also ensure that the set is operating properly should it be needed in an emergency GENERATOR MAINTENANCE Any ma...

Страница 14: ...ective capacitor Circuit breaker trips Defective load Defective receptacle Excessive load Problem Possible Causes Voltage too high Engine speed is too high Generator overheating Overloaded Insufficient ventilation No output voltage Short in load disconnect Tripped or defective circuit breaker Broken or loose wire Defective receptacle No residual magnetism in generator Defective stator Defective ro...

Страница 15: ...15 OPM 128 E RECEPTACLE WIRING DIAGRAM G2 G2 N N N N N N N G2 G2 G1 G1 G1 G1 GND GND GND GND ...

Страница 16: ...be furnished upon request THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED OR OTHERWISE CREATED INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY OR WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE WINCO is liable for the repair or replacement of the product only and is not liable for incidental or consequential damages as ...