![Winco DE50F4 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/winco/de50f4/de50f4_installation-and-operators-manual_984800016.webp)
16
OPM-143/E
CHANGING AIR FILTER
Do NOT remove filter while engine is running.
1. Remove the air filter cover (4) after having released the
two quick closing hooks (3).
2. Remove the filter (5). During this operation, take care
to ensure that no dust enters the sleeve.
3. Position the filter (5) in its seat.
4. Replace the cover (4) of the air filter and lock it in place
using the two quick release hooks (3).
CHECKING WATER IN PRE-FILTER
WARNING: EQUIPMENT DAMAGE
Clean the exhaust valve prior to checking the pre-filter to
reduce the risk for system contamination.
Do NOT perform while the engine is running.
1. Place a container for collecting liquids under the
pre-filter
(2).
2. Unscrew the plug (1) located at the bottom of the filter.
3. Drain the fluid until only fuel comes out.
4. Fully hand-tighten the plug.
5. Dispose of liquid in accordance to local codes. DO NOT
dispose or allow liquid to seep into the ground or
sewer systems, doing so will cause environmental
damage.
CLEANING RADIATOR
The surfaces of the radiator come into contact with the
outside air and can be subject to deposits and impurities.
Clean in accordance to the maintenance schedule with
compressed air or steam.
REPLACING BLOW-BY FILTER
Do NOT perform while the engine is running.
Using Illustration 1:
1. Remove the belt guard.
2. Unscrew the lower guard screws (2) and remove the
lower guard (1).
3. Save the anti-vibration plugs (3).
4. Unscrew the screws (4) and remove the fan guard (5).
Illustration 1