background image

3

OPM-103

REV B

COPY YOUR MODEL AND SERIAL NUMBER HERE

No other WINCO generator has the same serial number as yours. 

If you should ever need to contact us on this unit, it will help us to 

respond to your needs faster.

MODEL __________________________________________________

SERIAL NUMBER _________________________________________ 

PURCHASE DATE _________________________________________

DEALER NAME ___________________________________________

DEALER PHONE # ________________________________________

SAFETY

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important information that should be understood 

and followed before the installation, operation and maintenance of the 

generator. Failure to follow the safety instructions in this manual could 

result in serious injury or death. Keep this manual available for future 

reference.

ANSI SAFETY DEFINITIONS

DANGER:

DANGER indicates an imminently hazardous situation which, if not 

avoided, 

will 

result in death or serious injury. This signal word is to be 

limited to the most extreme situations.

WARNING:

WARNING indicates a potentially hazardous situation which, if not 

avoided, 

could

 result in death or serious injury.

CAUTION:

CAUTION indicates a potentially hazardous situation which, if not 

avoided, 

may

 result in minor or moderate injury. It may be used to alert 

against unsafe practices.

NOTE: CAUTION is also used on the unit labels and in this manual to 

indicate a situation that could result in serious damage or destruction of 

the equipment and possible personal injury.

1. ELECTRIC SHOCK - 

The output voltage present in this equipment can cause a fatal electric 

shock. This equipment must be operated by a responsible person.

 

 

A. Do not allow anyone to operate the generator without proper 

   instruction.

 

B. Guard against electric shock.

 

C. Avoid contact with live terminals or receptacles.

 

D. Use extreme care if operating this unit in rain or snow.

 

E. Use only three-prong grounded plugs and extension cords.

 

F.  Be sure the unit is properly grounded to an external ground rod 

 

  driven into the earth.

2. FIRE HAZARD -

 

 

A. Keep a fire extinguisher nearby  and know its proper use. Fire 

 

  extinguishers rated ABC by NFPA are appropriate.

3. NOISE HAZARD -

Excessive noise is not only tiring, but continual exposure can lead to 

loss of hearing.

 

 

A. Use hearing protection when working around this 

 

  equipment for long periods of time. 

 

B. Keep your neighbors in mind when permanently installing this 

   equipment.

4. CLEANLINESS -

Keep the generator and surrounding area clean.

 

 

A. Remove all grease, ice, snow or materials that create slippery 

 

  conditions around the unit.

 

B. Remove any rags or other materials that could create a 

 

  potential fire hazard.

 

C. Carefully clean up any gas or oil spills before starting the unit.

 

5.SERVICING EQUIPMENT -

All service, including the installation or replacement of service parts, 

should be performed only by a qualified technician.

 

 

A. Use only factory approved repair parts. 

 

B. Do not work on this equipment fatigued.

 

C. Use extreme caution when working on electrical components. 

 

  High output voltages from this equipment can cause serious 

 

  injury or death.

 

D. Installing a generator is not a “do-it-yourself” project. Consult 

 

  a qualified, licensed electrician or contractor. The installation 

 

  must comply with all national, state, and local codes.

TESTING POLICY

Before any generator is shipped from the factory, it is fully checked 

for performance. The generator is loaded to its full capacity, and the 

voltage, current, and frequency are carefully checked.

Rated output of generator is based on engineering tests of typical units, 

and is subject to, and limited by, the temperature, altitude, fuel, and 

other conditions specified by the manufacturer of applicable engines.

Содержание DE SERIES

Страница 1: ...INCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS DE SERIES GENERATORS MANUAL MANUAL KEY START AND DSE4510 ELECTRIC START...

Страница 2: ...lected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that you carefull...

Страница 3: ...oper instruction B Guard against electric shock C Avoid contact with live terminals or receptacles D Use extreme care if operating this unit in rain or snow E Use only three prong grounded plugs and e...

Страница 4: ...ations Oil Type See Lubrication section in this manual Oil Capacity 8 6 Quarts Cooling System 50 50 mix SPECIFICATIONS DE20I4 MODEL DE20I4 3 DE 20I4 4 DE20I4 17 DE20I4 18 Generator Wattage 20 000 20 0...

Страница 5: ...ifications Oil Type See Lubrication section in this manual Oil Capacity 13 5 Quarts Cooling System 50 50 mix DE65F4 MODEL DE65F4 3 DE 65F4 4 DE65F4 17 DE65F4 18 Generator Wattage 55 000 62 000 62 000...

Страница 6: ...ont cover of this manual for future reference and for identification whenever requesting field or factory assistance Primary fields needed for assistance are complete model number and serial number EN...

Страница 7: ...ting the generator Due to the different designs configurations options weights site conditions and available material handling equipment specific lifting instructions are not provided for each individ...

Страница 8: ...mes larger than the radiator face The extra air inlet area is required to minimize restriction and to provide combustion air for the engine Do not block fresh air intakes with other equipment as this...

Страница 9: ...start up A customer supplied 12 Volt battery is required to complete the installation Installation of the highest CCA rated battery within the correct BCI group will increase cold weather starting pe...

Страница 10: ...make sure that a new battery is fully charged before installing it on a generator set Failure to do so can cause damage to the engine control module in the generator set All connections must be clean...

Страница 11: ...r and the load Based on wire type and temperature rating Wire has been derated for 40 C ambient temperature Wire Temperature Rating CB AMP Cu Conductor AI Conductor kW Voltage PH 75 C 90 C 75 C 90 C 2...

Страница 12: ...to verify correct installation before starting the engine Engine oil Fill as required with proper grade qty Engine coolant Fill as required with proper mixture Unit mounting base properly bolted down...

Страница 13: ...tion Warning alarms are self resetting when the fault condition is removed The icon will appear steady in they display SHUTDOWN Shutdowns are critical alarm conditions that stop the engine and draw th...

Страница 14: ...fter the Safety On timer has expired Generator Under Frequency The generator frequency has fallen below the pre set pre alarm setting after the Safety On timer has expired Generator Over Frequency The...

Страница 15: ...ng the engine Engine oil Fill as required with proper grade qty Engine coolant Fill as required with proper mixture Unit mounting base properly bolted down Clearance for service and maintenance on all...

Страница 16: ...16 OPM 103 REV B KEY START PANEL SCHEMATIC WIRE 91 IS NOT INCLUDED WITH THE DE45 DE90 MODELS CONTROL BOX AC WIRING...

Страница 17: ...EMATIC DE20 DE30 ENGINE HARNESS SCHEMATIC 7 7 51 725 0 67 57 5 3 8 3803 8 1 2 35 668 5 6 1 5 22 17 7 03 6 1 5 8 9 6 1 5 2 3 8 6 1 725 2 3 8 6 5 67 57 62 12 2 22 17 127 6 22 17 1 2 35 6685 6 7 67 1 5 6...

Страница 18: ...18 OPM 103 REV B 4510 ELECTRIC START PANEL...

Страница 19: ...19 OPM 103 REV B THREE PHASE AC WIRE HIGH AND LOW WYE THREE PHASE AC WIRING DELTA SINGLE PHASE 311 WINDING...

Страница 20: ...d fitness for a particular purpose are limited to 12 months or 1000 hours which ever occurs first from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some st...