INSTALLATION

FOUNDATION MOUNTING

Mount the generator on a foundation if it is to be used as 

a permanent or standby power source. When planning a 

foundation consider the following points:

A. The foundation location should enable aligning the drive 

  shaft (tumbling bar) in a straight or nearly straight line 

  between the power take-off and the generator input 

  shaft. Misalignment must be less than 5 degrees during 

  generator operation, even though the mechanical design 

  of the tumbling bar would allow greater misalignment.

B. The foundation must be solid enough to absorb 

  generator starting and reflected load torque during 

 operation.

C. The foundation surface should be flat.

D. Space is required around the generator for mounting 

  switching devices, making connections, and for servicing.

E. For dimensions needed for install for your specific 

  generator, please refer to it’s outline drawing. The 

  hardware needed is dependent on your distinct 

 application.

F. The generator mounting bracket must rest evenly and 

  firmly on the foundation. Install shims if necessary to even 

  out the foundation under the mounting pads then bolt 

  the generator firmly in place. 

TRAILER MOUNTING

Optional

Mount the generator on a trailer if you plan to use it as a 

portable power source. When selecting or building a trailer 

to mount the generator, consider the following points:

A. The trailer construction must be strong enough to 

  support the generator.

B. The design of the trailer must enable the trailer to remain 

  stable during operation, and to resist tipping caused by 

  generator starting and reflected load torque.

C. The trailer height and mounting position of the 

  generator on the trailer should enable aligning the drive 

  shaft (tumbling bar) in a straight or nearly straight line 

  between the power take-off and generator input shafts. 

  Misalignment must be less than 5 degrees during 

  generator operation, even though the mechanical design 

  of the tumbling bar would allow greater misalignment.

D. The generator mounting area of the trailer bed should 

  be flat.

The frame pads must rest firmly on the trailer bed. Install 

shims if necessary to even out the bed under the mounting 

pads, then bolt the generator firmly in place.

WARNING: Personal Injury & Equipment Damage

Trailer may tip over and cause injuries if wheels are not 

spaced far enough apart.

THREE-POINT HITCH KIT

Optional

WARNING: PERSONAL INJURY & EQUIPMENT 

DAMAGE

When using the 3-point hitch assembly all three points 

must be attached to the tractor. Failure to do so will cause 

the generator to tip when lifting it, damaging both the 

t-bar and the generator.

A. The three point hitch must be attached to the tractor at 

  all times during operation.

B. When operating the generator the three point hitch and 

  generator must be sitting on flat level ground. All four 

  deck pads must be in constant contact with the ground 

  at all times. This will reduce the vibration in both the 

  generator and the tumbling bar.

C. For safety the generator must be bolted to the three 

  point hitch deck using all four mounting bolts.

Содержание 27PTOC4-03

Страница 1: ...r need to contact us on this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _________________________________________ PURCH...

Страница 2: ...THREE PHASE 36 MONTH LIMITED WARRANTY 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the gen...

Страница 3: ...by NFPA are appropriate CAUTION NOISE HAZARD Excessive noise is not only tiring but continual exposure can lead to loss of hearing A Use hearing protection when working around this equipment for long...

Страница 4: ...s 120 240 Phase Three Amps 87 Input Speed 540 RPM Generator Speed 1800 RPM AVR AS540 Input Shaft 1 3 8 6 spline Required Tractor PTO HP 63 30PTOT4 17 Watts 31 600 Volts 120 240 Phase Three Amps 87 Inp...

Страница 5: ...equired for full power operation The generator will work but produce only as much kW output as the tractor can supply HP for For example a 20 HP output tractor will deliver a maximum of approximately...

Страница 6: ...is noted it is always easiest to refuse the shipment and let WINCO take care of the freight claim If you sign for the unit the transfer of the ownership requires that you file the freight claim 2 Bef...

Страница 7: ...generator B The design of the trailer must enable the trailer to remain stable during operation and to resist tipping caused by generator starting and reflected load torque C The trailer height and m...

Страница 8: ...r switch isolates the load from the power line and allows you to safely operate your loads without endangering the power line repair crew See diagram on page 8 The load connected to the normal termina...

Страница 9: ...imped with an appropriate compression crimper or both Approved Crimping tools are 1 Anderson Power Products 2 ETC Model HHS hydraulic crimper 3 ITT Blackburn NO 1640 4 T B Thomas Betts TBM5 To complet...

Страница 10: ...TS WITH EMERGENCY POWER IMPORTANT When making standby service hook up make sure load to be transferred to standby generator will not exceed generator rating Watthour Meter Watthour Meter To Power Line...

Страница 11: ...e load disconnect receptacle is the largest gray receptacle on the generator output panel To aid in determining how much load can be applied to the generator and how it should be distributed among the...

Страница 12: ...he drive shaft tumbling bar is assembled with its universal joint knuckles synchronized If the knuckles are not synchronized the bar will chatter when rotating which will cause the generator output vo...

Страница 13: ...t should be checked each time you use the generator As a quick check you can plug in a trouble light and check for normal brightness 4 With engine and generator running smoothly switch on the electric...

Страница 14: ...se Mobil SAE 85W90 140 API Service GL 5 Sunoco DX XL80W90 140 Kendal Three Star 85W 140 Amoco 85W140 or equivalent CAUTION Equipment Damage Do not overfill generator gear case Overfilling causes overh...

Страница 15: ...sure compressed air regulated at 25 35 PSI to clean the generator periodically WARNING Do NOT clean the generator while it is running Proceed as follows 1 Remove control box cover Vacuum or blow dust...

Страница 16: ...R 7 Shorted or open rotor 8 Shorted or open stator 1 Reset circuit breakers replace if defective 2 Disconnect the load Check voltage at receptacle cord set Check motors appliances and load leads for s...

Страница 17: ...17 OPM 136 D WIRING DIAGRAM 120 240V SINGLE PHASE BACK VIEW G1 G2 N N N G2 G2 GND GND GND GND GND G2 G2 G2 G2 G1 G1 G1 G1 G1...

Страница 18: ...18 OPM 136 D G1 G1 G1 G1 GND GND GND GND GND G1 G1 G2 G2 G3 G3 G2 N N N N G2 G2 G2 120 208V 120 240V THREE PHASE BACK VIEW...

Страница 19: ...19 OPM 136 D 277 480V THREE PHASE BACK VIEW GND GND GND N N N N N G3 G3 G2 G2 G1 G1 G1 G1 G1 G1...

Страница 20: ...you may have other rights which vary from state to state Note Some states do not allow limitation on the duration of implied warranty and some states do not allow the exclusion or limitation of incid...

Отзывы: