background image

WINCHESTER

 

BY

 

MORTEX

 

PRODUCTS

 

INC

 

FORT

 

WORTH,

 

TX

 

76106

 

Page

 

1

 

 

INSTALLATION MANUAL 

 

DOWNFLOW / HORIZONTAL 
ELECTRIC FURNACE 

MODELS: 

WEFC 

WEFX 

SERIES 

      

 

 

LIST OF SECTIONS 

 

1 – General 

 

 

 

 

6 – Line Voltage and Control Box Wiring 

 

 

2 – Safety 

 

 

 

 

7 – Thermostat Wiring and Connections 

 

 

10 

3 – Return Air and Clearance Requirements 

 

8 – Motor, Blower and Furnace Startup   

 

 

14 

4 – Supply Air and Duct Connector Installation 

 5 

– 

Final 

System 

Checkout 

    15 

– 

Furnace 

Installation 

   6 

10 

– 

Wiring 

Diagrams 

    16 

 

LIST OF FIGURES 

 

1 – Furnace Dimensions 

 

 

 

17 – Control Box Power, Blower & Fuse Connections 

 

10 

2 – Closet Clearances 

 

 

 

18 – Separate Thermostats, Same Furnace Wiring Diagram   

12 

3 – Typical Closet Installations 

 

 

19 – Same T’stat, Separate Furnace - Separate Trans Connections 

12 

4 – Typical Alcove Installations 

 

 

20 – Same T’stat, Separate Furnace and Cooling Unit Connection 

12 

5 – Clearance – Access for Service 

 

 

21 – Typical Heating/Cooling Separate Transformer Connections 

13 

6 – Duct Connector Depths   

 

 

22 – Typical Heat Pump/Heating/Cooling T’Stat Connections 

13 

7 – Duct Connector and Floor Base Installations 

 6 

23 

– 

X-13 

motor 

Terminals 

    14 

8 – Duct Connector Measurements 

 

 

24 – Blower Assembly and Blower Deck 

 

 

15 

9 – Duct Connector and Floor Base Measurements 

25 – Wiring Diagram 5 kW w/ X-13 Blower Motor 

 

17 

10 – Return Air Grille and Frame Assembly 

 

26 – Wiring Diagram 8 kW, 10 kW, 12kW w/ X-13 Blower Motor 

18 

11 – Grille and Frame Assembly Filter Locations  

27 – Wiring Diagram 15 kW, 17kW w/ X-13 Blower Motor  

19 

12 – Coil Cabinet Door Bracket Location 

 

28 – Wiring Diagram 20 kW w/ X-13 Blower Motor 

 

20 

13 – Control Box Component Locations 

 

29 – Wiring Diagram 5 kW w/ PSC Blower Motor 

 

21 

14 – Control Box Cover and Circuit Breaker Location 

10 

30 – Wiring Diagram 8 kW, 10 kW, 12kW w/ PSC Blower Motor 

22 

15 – Line Voltage Electrical Shield 

 

 

10 

31 – Wiring Diagram 15 kW, 17kW w/ PSC Blower Motor  

23 

16 – Line Voltage Electrical Shield Location 

 

10 

32 – Wiring Diagram 20 kW w/ PSC Blower Motor 

 

24 

  

LIST OF TABLES 

 

1 – Electric Furnace Model Specifications 

 2 

– 

Electrical 

Data 

     9 

2 – Model Nomenclature 

 

 

 

9 – Low Voltage Wire Gauge and Max Lengths   

 

10 

3 – Optional Cooling Cabinets and Return Air Grille 

10 – Recommended Heat/Cool T’stat Wire Color Code 

 

12 

4 – Clearances to Combustibles 

 

 

11 – Recommended Heat/Cool/HP T’stat Color Code 

 

12 

5 – Duct Connectors 

 

 

 

12 – X-13 Motor Terminal Connections  

 

 

14 

6 – Wiring Requirements – Single Branch Circuit  

13 – X-13 Motor Factory Speed Tap Settings 

 

 

16 

7 – Wiring Requirements – Dual Branch Circuit   

 

 
SECTION I: GENERAL 

 
The following list includes important facts and information 
regarding the electric furnace and its inclusions.  
 

1.

 

Furnace is rated at 240 volts AC at 60 Hertz 

2.

 

Furnace is the same size for all models 

3.

 

Four-wire thermostat operation for heating and cooling 

4.

 

A/C ready furnaces equipped with blower for A/C or 
Heat Pump operation. 

5.

 

Holding Strap furnished with furnace. 

6.

 

This furnace is designed for downflow/horizontal 
application. 

7.

 

This furnace must not be operated without furnace door 
installed. 

 

 
 
NOTE: This furnace and its components listed on the 
A/C and Heat Pump equipment sticker were listed in 
combination as a system by ETL for the United States. 
 
 
 
 

Содержание WEFC**48

Страница 1: ...l Cabinet Door Bracket Location 7 28 Wiring Diagram 20 kW w X 13 Blower Motor 20 13 Control Box Component Locations 9 29 Wiring Diagram 5 kW w PSC Blower Motor 21 14 Control Box Cover and Circuit Brea...

Страница 2: ...Blower Motor Heat Strip kW Blower Motor HP W Winchester E Electric Heat F Furnace 42 1 3 HP 48 1 2 HP 60 3 4 HP 10 10 kW 12 12 kW 15 15 kW 20 20 kW C PSC Blower Motor X X 13 Blower Motor Table 2 Furn...

Страница 3: ...replacing the air filters Observe all precautions in the manuals and on the attached labels when working on this appliance 11 These instructions cover minimum requirements and conform to existing nati...

Страница 4: ...opening FOR A C and HP Furnaces 3 4 HP Blower Minimum 390 in free area opening Use Return Grille or A C Coil Cabinet or any return grille with a minimum 390 in free area opening Top Return Only Recom...

Страница 5: ...90 DCU0 03 11 90 DCU0 03 12 90 DCU0 03 Table 5 Duct Connectors Figure 6 Duct Connector Depths Installing the Duct Connector 1 Attach the four seal strip foam tape gaskets provided with the duct conne...

Страница 6: ...TALLATION Installing the Furnace with a Return Air Grille Frame Assembly Alcove Installation This kit is approved for use in an alcove heating only installation without an air conditioning coil The re...

Страница 7: ...emove the coil cabinet from the box and assemble per the instructions 6 Lay the coil cabinet on its back and place the coil cabinet flanges against the furnace top cover 7 Place coil cabinet door brac...

Страница 8: ...n on the wire 11 If you are using a dual circuit for a 15kW 17kW or 20kW model you will need to insert both green wires into the ground lug and tighten the set screw 12 Tighten the screws on the cable...

Страница 9: ...99 10 12 0 10 4 99 12 0 4 99 10 10 BTU 15 876 26 512 33 686 38 612 33 686 15 876 38 612 15 876 33 686 33 686 kW 4 65 7 77 9 78 11 32 9 78 4 65 11 32 4 65 9 78 9 78 BTU 14 736 23 339 30 222 36 483 30...

Страница 10: ...ow Voltage Wire Gauge and Max Lengths Figure 17 Control Box In coming Power Low Voltage Wiring Blower Wiring and Low Voltage Fuse Locations For personal safety be sure to turn the electrical power OFF...

Страница 11: ...air preferably where there is air movement back to furnace Locating height of thermostat is important Thermostat should be located preferably in a hall way upstream from the furnace return airflow not...

Страница 12: ...ections RED 24 VAC R Red R N A WHITE Heat 1st Stage Heat W White W or W1 N A GREEN Indoor Fan G Green G N A YELLOW Cooling Stage 1 Y Yellow Y or Y1 Y or Y1 BROWN 24 VAC Common BRN Brown C C Table 10 R...

Страница 13: ...met in the right side of the casing and place the thermostat wire cable on the right side of the control box next to the low voltage pigtails 5 Connect the Red 24 VAC supply wire from the thermostat t...

Страница 14: ...the main service House Circuit Breaker panel Figure 23 X 13 Motor Terminals Replacing the Blower Motor 1 Turn off all electrical supply circuits to the furnace at the main service panel 2 Remove furn...

Страница 15: ...aks found 7 Set the blower selector switch to the AUTO position 8 Set the thermostat above the room temperature to check for proper operation of the electric heaters 9 Set the thermostat to the desire...

Страница 16: ...WINCHESTER BY MORTEX PRODUCTS INC FORT WORTH TX 76106 Page 16 Table 13 X 13 Motor Factory Speed Tap Settings...

Страница 17: ...25 5 kW Electric Heater Wiring Diagram with a Standard Digital Heating Cooling Heat Pump Single or Two Stage Programmable Thermostat X 13 blower motor NOTE IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH T...

Страница 18: ...W Electric Heater Wiring Diagram with a Standard Digital Heating Cooling Heat Pump Single or Two Stage Programmable Thermostat X 13 blower motor NOTE IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNI...

Страница 19: ...Electric Heater Wiring Diagram with a Standard Digital Heating Cooling Heat Pump Single or Two stage Programmable Thermostat X 13 blower motor NOTE IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT...

Страница 20: ...ctric Heater Wiring Diagram with a Standard Digital Heating Cooling Heat Pump Single or Two Stage Programmable Thermostat X 13 blower motor NOTE IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUS...

Страница 21: ...Electric Heater Wiring Diagram with a Standard Digital Heating Cooling Heat Pump Single Stage Programmable Thermostat PSC blower motor NOTE IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE...

Страница 22: ...12kW Electric Heater Wiring Diagram with a Standard Digital Heating Cooling Heat Pump Single Stage Programmable Thermostat PSC blower motor NOTE IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUS...

Страница 23: ...17kW Electric Heater Wiring Diagram with a Standard Digital Heating Cooling Heat Pump Single Stage Programmable Thermostat PSC blower motor NOTE IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUS...

Страница 24: ...d Digital Heating Cooling Heat Pump Single Stage Programmable Thermostat PSC blower motor NOTE IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THIS UNIT MUST BE REPLACED IT MUST BE REPLACED WITH TYPE 105 C...

Отзывы: