WINCHESTER
BY
MORTEX
PRODUCTS
INC
FORT
WORTH,
TX
76106
Page
7
Figure 10: Return Air Grille Frame Assembly
Figure 11: Return Air Frame Assembly Filter
Location
Installing the Furnace and Coil Cabinet
Closet Installation
This kit is approved for use in an alcove or closet installations
with an approved air conditioning coil. The coil cabinets are
available in 23.25”, 30.50” and 41.25” height. The furnace is
33” in height making the total furnace and coil cabinet heights
56”, 63” and 73”. To install the coil cabinet assembly to the
furnace, follow the steps below:
Prior to installing the furnace make sure the holes are cut into
the floor for the refrigerant tubing, the drain line, the electrical
wiring, the thermostat wiring and the condenser control
wiring.
1.
Before installing the coil cabinet on the furnace, be sure
you have enough clearance to install the furnace and the
filter door assembly.
2.
Remove the top shipping cover and corner posts.
3.
Remove the bottom shipping cover.
4.
Remove the front access panel (door) and lay the furnace
on its back.
5.
Remove the coil cabinet from the box and assemble per
the instructions.
6.
Lay the coil cabinet on its back and place the coil cabinet
flanges against the furnace top cover.
7.
Place coil cabinet door bracket between the coil cabinet
flanges and the furnace top as shown in Figure 12.
8.
Install the screws through the holes provided in order to
secure the cooling coil cabinet to the top of the furnace.
9.
Slide the furnace on to the floor base. Push the furnace
back until the furnace casing is against the rear flange.
10.
Secure the furnace to the floor by drilling two holes
through the furnace base and the floor base at the right
and left front inside corners of the cabinet. Use two
screws to secure the furnace to the floor.
Figure 12: Coil Cabinet Door Bracket Location
SECTION VI: LINE VOLTAGE WIRING
Power Supply
The furnace internal wiring is complete except for the power
supply and the thermostat wires. See wiring diagram and/or
Tables 6 and 7 for wire size, fuse/circuit breaker size, and
ground wire sizes. The use of cable connectors on incoming
power supply wires to relieve any strain on wiring is
recommended. Follow the steps below to connect the power
supply wires.
Single Circuit Line Wiring Connections
1.
Remove the control box cover.