9.5
AC Measurement Conditions
PARAMETER SYMBOL
SPEC
UNIT
MIN MAX
Load Capacitance
C
L
30
pF
Input Rise and Fall Times
T
R
, T
F
5 ns
Input Pulse Voltages
V
IN
0.1 VCC to 0.9 VCC
V
Input Timing Reference Voltages
IN
0.3 VCC to 0.7 VCC
V
Output Timing Reference Voltages
O
UT
0.5 VCC to 0.5 VCC
V
Note:
1. Output Hi-Z is defined as the point where data out is no longer driven.
I
Timi
Input Levels
0.9 VCC
0.1 VCC
nput and Output
ng Reference Levels
0.5 VCC
Figure 59. AC Measurement I/O Waveform