42 Shower control
WimTec PROOF S6 -
Hy
Plus
EN
PROOF S6 -
Hy
Plus
The time set on the minimum flushing duration control can be checked by flashing the
monitoring LED in the infrared sensor (see p. 29).
Visualisation of the minimum flush duration:
Description of the functions
i
Note:
While the set minimum flushing duration is indicated by the
monitoring LED flashing, the fitting goes out of operation.
The fitting will resume normal operation following the
visualisation.
By changing the “OFF” position of DIP switch 4, the
automatic flush is deactivated and the visualisation of the
set minimum flush duration is interrupted.
1
DIP switch 4
By changing the DIP switch position to “ON”, the monitoring
LED starts to flash for the time set on the minimum flushing
duration control in the second cycle.
2
Minimum flushing duration control (if DIP switch 4 = “ON”)
If the time is changed by turning the minimum flushing
duration on the controller, the monitoring LED starts to flash
5 s after the change for the set duration in a second cycle.
Activate visualisation of the minimum flush duration:
1 2 3 4 5 6
ON
OFF
1
2
um 07:00 Uhr
um 07:00 Uhr
Содержание PROOF S6 HyPlus