32 Shower control
WimTec PROOF S6 -
Hy
Plus
EN
PROOF S6 -
Hy
Plus
Assembly
8
7.
Mount adapter for thermostat using the 2.5 Allen key (with the arrow pointing upwards).
8.
Feed the power connection cable (2 x 0.5 mm
2
) and the control line for thermal disinfection
(2 x 0.5 mm
2
YSLCY-OZ) into the flush-mount set and connect it/them to the power supply
(art. no. 117 899, 113 792).
Attention: The power supply must not be installed in the flush-mount set!
9.
Attach the mounting frame using the 4 screws (M5 x 40 mm). Make sure that the cable
connections remain intact and the cables are not crimped.
10.
Correctly align the mounting frame and securely fasten the screws. When tightening the
screws, ensure that the mounting frame does not get warped. Apply the included special
grease to the front of the gasket.
11.
Connect the magnetic valve to the electronics module (red marking = thermal disinfection).
12.
Connect the power cables to the electronics module (Make sure to use the correct polar-
ity +/-). Then switch on the power supply (causing the safety locking mechanism of the
magnetic valves to activate). Where necessary, connect the bus control line to the electronics
module (see p. 34).