EN
INSIDE
30 Urinal control WimTec INSIDE
Description of the functions
If the device is used more frequently than twice per 1.5 minutes, the
control enters stadium mode and starts flushing once every minute.
‘ON’ position:
Stadium mode enabled.
‘OFF’ position:
Stadium mode disabled (default setting).
Stadium mode:
DIP switch 6
ON
OFF
2 3 4 5 6
1
Description of the LED signals:
LED 1
LED 2
Description
OFF
OFF
No user
ON
OFF
User detected
ON
ON
Flushing
OFF
ON
Extra rinse (Automatic flushing, stadium mode) or
no magnetic valve is connected.
OFF
Flashing
Dry-out protection: Siphon is filling up
Flashing
Flashing
Blockage protection
OFF
Flashing
No magnetic valve is connected (during or after flushing)
LED signals