WilTec CSF-500 Скачать руководство пользователя страница 2

 

The information contained in this document is subject to change without prior notice. No part of this
document can be copied or duplicated in another form without

 

the prior written consent of  Wiltec

Wildanger Technik GmbH. The Wiltec Wildanger Technik GmbH assumes no liability for any errors in
this user manual or the connection diagram.
Although Wiltec Wildanger Technik GmbH has made every effort to make sure that this user manual is
complete, accurate and updated, errors cannot always be avoided. In the event of problems with this
user manual please complete and send this form back to us.

FAX-notification (

+49 2403 55592-15

), 

 
from: ________________________________________
 
Name: 

________________

 

Firm:

_____________________

 

Tel/Fax:

__________________

 

I would like to report the following mistakes: 

 
 
 
 

_______________________________

 

 ____________________________________

 

Customer Service Wiltec Wildanger Technik GmbH 
e-mail: 

[email protected]

Tel: +49 2403 55592-0

Introduction

Thank you for purchasing this quality product.

  To minimize the risk of injury by means of fire or

electric shock we urge that our clients take some basic safety precautions when using this
device. Please read the operation instructions carefully and make sure you have understood its
content.

Always use a grounded power connection with the appropriate mains voltage. You can

find the corresponding mains voltage on the type plate. If you have any doubts about the
connection   being   grounded,   have   it   checked   by   a   qualified  professional.   Never   use   a

faulty electric cable.
Do not inspect the electrical part of the pressure pond filter in a wet or damp environment

or when you are wet yourself and protect it from direct sunlight. Install this device in a
safe location so that nobody can step on the cable, fall over or damage it. Disconnect the

power   plug   before   cleaning   it   and   use   only   a   damp   cloth   for   cleaning.   Avoid   using
cleaning agents and 

make sure that no liquid enters the electrical part of the pump.

The electric part of the device contains no parts that can be inspected or serviced by the user. Leave
the   maintenance,   adjustment   and   repair   to   qualified   technical  personnel.   In   case   of   unauthorised
intervention the 2-year warranty is no longer valid! Keep these operation instructions safe.

© by WilTec Wildanger Technik GmbH 

Seite 11 

http://www.wiltec.de
http://www.aoyue.eu
http://www.teichtip.de

Version 07.2015

Содержание CSF-500

Страница 1: ...reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us by WilTec Wildanger Technik GmbH Seite 10 http www wiltec de http www aoyue eu http www teichtip de Version 07 2015 ...

Страница 2: ...ge that our clients take some basic safety precautions when using this device Please read the operation instructions carefully and make sure you have understood its content Always use a grounded power connection with the appropriate mains voltage You can find the corresponding mains voltage on the type plate If you have any doubts about the connection being grounded have it checked by a qualified ...

Страница 3: ...ke sure no children or adult sit on this filter 4 do not connect this filter to any taps The high pressure from the taps exceeds the maximum allowable working pressure 5 do not use solvents for cleaning the filter this could damage the filter especially its finish CAUTION PLEASE KEEP THIS MANUAL HANDY FOR FUTURE USE OPEN THE PACKAGE 1 Please carefully check the accessories and products when open t...

Страница 4: ...lled with 30 filter materials 1 Connecting pipe after position 2 Open the filter cover 3 Fill the filter with water to half capacity 4 Pour the required quantity of filter materials inside CAUTION not drop any inside the inner pipe 5 Clean the sealing at the joint part 6 Fix the filter cover in place CAUTION 1 the filter should be installed as close as possible to the pool and best in the water 0 ...

Страница 5: ...tallation in the FILTRATION position The water flowing into the pool will be cloudy from a few seconds So to prevent it from reaching the pool there is RINSE position from the selector valve which is operated as following immediately after the BACKWASH put the valve in the RINSE position and switch on the pump fro 1 minute after which the pump is switched off and the valve placed in the FILTRATION...

Страница 6: ...vity 4 When you need to start up the filter again after a period of inactivity follow the instructions stated in the paragraph START UP DRAWING No name No name No name 1 cover 6 packet ring 11 UVC device head 2 screw 7 quartz tube 12 filter tank 3 gasket 8 o ring 1 13 rubber gasket 4 shim 9 o ring 2 14 sealing nut 5 nut 10 UVC lamp 36W 15 bio cell by WilTec Wildanger Technik GmbH Seite 15 http www...

Страница 7: ... points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce the consum...