WilTec CHJ 502 Скачать руководство пользователя страница 5

  

© by WilTec Wildanger Technik GmbH  

 

Seite 5  

http://www.wiltec.info  

 

 

 

Filter basket 

11  Air inlet plug  

Filter sponge 

12  Enginge housing  

Large filter sponge  13  O-Ring 

Connector 

14  Axe 

Controller 

15  Rotor 

Air inlet 

16  bearing 

Outlet 

17  Pump housing 

Air inlet 

18  Guiding 

Supply line 

19  Suction cup 

10  Valve Air inlet  

 

 

 
Cleaning  
 
Disconnect the pump from the power supply and remove it from the water. By pulling and moving you 
carefully separate the engine housing from the impeller chamber. Remove the impeller and the shaft 
and clean them with a brush. You can remove resistant debris by putting these parts in vinegar. 
Please rinse the parts thoroughly before you put them back into the pump.  
 
The plastic bearings, ceramic shaft and the like are wear parts. If, despite regular cleaning, the pump 
generates significant operating noise after prolonged operation, it may be useful to replace these 
parts.  
Please clean the sponge regularly in order to avoid an impact on the pump performance. 
 
 
 
 
 
 

 