WilTec 62138 Скачать руководство пользователя страница 5

 

© by WilTec Wildanger Technik GmbH  

Item 62138, 62139 

Page 5 

 

http://www.WilTec.de

 

http://www.aoyue.eu   

   

06 2021

-1

 

http://www.teichtip.de

 

 

 

ATTENTION:

 

 

 

Carry out a visual inspection of the device before carrying out regular inspections. Do not use 
the device if safety devices are damaged or worn. Never disable safety devices. 

 

Only use the device for the purpose specified in these operating instructions. 

 

You are responsible for safety in the work area. 

 

If the cable or plug is damaged due to external influences, the cable must not be repaired! It 
must be replaced with a new one. This work may only be carried out by a qualified electrician. 

 

The voltage of 230 V (50 Hz) AC specified on the type plate of the device must correspond to 
the existing mains voltage. 

 

Never lift, transport or attach the device to the mains cable. 

 

Make sure that the electrical plug connections are located  in the flood-proof  area or are pro-
tected from moisture. Disconnect the mains plug before carrying out any work on the device. 

 

Avoid exposing the device to a direct jet of water. 

 

The operator is responsible for compliance with local safety and installation regulations. Ask a 
qualified electrician if necessary. 

 

The user must take suitable measures (e.g., installation of alarm system, reserve pump, etc.) to 
prevent consequential damage caused by flooding of rooms in the event of malfunctions of the 
device. 

 

In the event of a failure of the device, repair work may only be carried out by a qualified electri-
cian. 

 

The unit must never run dry or be operated with the suction line fully closed. The manufacturer’s 
warranty expires for damage to the unit caused by dry running. 

 

The device must not be used for the operation of swimming pools. 

 

The unit must not be installed in the drinking water circuit. 

 

The pumping of aggressive liquids and abrasive materials must be avoided in any case. 

 

The pump must be protected from frost. 

 

The pump must be protected against dry running. 

 

The unit must not be installed in seepage pits or pump shafts. 

 

The consumers connected to the unit must not be used in the event of power interruptions. 

 

It is recommended to use a socket only for the unit. 

 

The device can only  dispose of faeces,  toilet paper,  acidic, fatty  and hot water  (up to 80 

). 

Avoid  throwing  inappropriate  objects,  toiletries,  or  fibrous  material  as  this  may  damage  the 
pump. 

 

Make sure that the consumers connected to the appliance do not have any water leaks, as in 
this case the pump would operate unnecessarily. In addition, in the event of a power interruption, 
a water leakage from one of the consumers would cause a water leakage from a device oper-
ating below the backwater level. 

 

If the bathroom or home is not used for a long time, it is recommended to close the main tap. 

 

This device can be used by children, aged 8, if under observation, or if they receive and under-
stand the instructions relating to safe use of the device with the hazards involved. Cleaning and 
maintenance by the user should not be performed by children who are not older than 8 years of 
age and operate under supervision. Keep all power cables out of the reach of children under 
8 years of age. 

 

The equipment may be used by persons with limited physical, sensory or mental abilities or lack 
of experience and knowledge if they are supervised, or if they receive and understand the in-
structions relating to safe use of the equipment with the hazards involved. 

 

Children should not play with the device. 

 

 WARNING:

 

 

Read  all  safety  instructions  and  instructions.  Failure  to  follow  the  safety  precautions  and  instructions 
may result in electric shock, fire and/or serious injury. Keep all safety information and instructions in a 
safe place for future reference. 
 

 

Содержание 62138

Страница 1: ...perating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insign...

Страница 2: ...ervice wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Ou...

Страница 3: ...rience and or knowledge unless they are supervised or instructed by a person responsible for their safety how to use this device Children should be supervised to ensure that they do not play with the...

Страница 4: ...eu 06 2021 1 http www teichtip de Safety instructions CAUTION On standing waters garden and swimming ponds and in their surroundings the device may only be used with a residual current circuit breaker...

Страница 5: ...drinking water circuit The pumping of aggressive liquids and abrasive materials must be avoided in any case The pump must be protected from frost The pump must be protected against dry running The uni...

Страница 6: ...cording to the EU standard the centre of the horizontal outlet must be 18 cm above the floor shell 18 cm above FFB Important PRESSURE LESS When connecting a washing machine to the lifting unit the was...

Страница 7: ...agram The non return valve included in the packaging must be installed The standard EN 12050 3 EN 12050 4 stipulates that if a WC is connected only a shower a bidet and a washbasin can be connected to...

Страница 8: ...s on the top side of the appliance and the other consumers in the bathroom or kitchen are the thin sides of the appliance The connected appliances should be operated separately and not continuously e...

Страница 9: ...on piece the pipe should have a diameter of 40 or 32 mm Seal the connection with the clamp Checking the assembly of the check valve If the waste water is to be pumped upwards install the check valve a...

Страница 10: ...the pipes there is residual water in the shower tray Maintenance and cleaning Read the safety instructions and instructions carefully before opening the unit for maintenance Maintenance should only b...

Страница 11: ...e pump impeller for blockage when the mains plug is unplugged The non return valve has been mounted the wrong way round Mount the non return valve in the correct direction is launched in unintended ma...

Страница 12: ...herwise the pressure switch of the lifting unit will be damaged and the automatic on off switch will no longer function correctly In the case of heavy blockages blockages caused by solids which have j...

Страница 13: ...er European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste bu...

Отзывы: