Electrical connection 

 

The electrical connection takes place via an electric safety socket 230 V ~ 50 Hz. Fuse protection 
at least 10 Amperes. 

 

The appliance is turned on/off by means of the ON-/OFF-switch. The indicator light of the switch 
glows, if the engine is started. 

 

The engine is protected against overloading or blocking by means of a built-in motor protection. In 
case of overheating the pump is turned off automatically due to the overheat protection and after 
the cooling the pump is automatically started. 

 
 

Suction line 

 

Connect a suction hose (plastic hose min. 3/4" spiral reinforced) directly or with a thread nipple to 
the suction connection (1" internal thread) of the pump. 

 

The  suction  which  is  used  should  have  a  suction  valve.  In  case  the  suction  valve  cannot  be 
employed a check valve should be installed in the suction line. 

 

Position the suction line from the water withdrawal to the pump on a rising gradient. Avoid by all 
means  placing  the  suction  line  higher  than  the  pump height,  air  pockets  in  the  suction  line  slow 
down and impede the suction process. 

 

The suction and the pressure line have to be installed in such a way, so that they do not exert any 
mechanical pressure on the pump. 

 

The suction valve should lie deeply enough in the water, so that a drop in the water level cannot 
lead to the dry running of the pump. 

 

A leaking suction line prevents the suction of water due to air intake.  

 

Avoid sucking in foreign particles (sand etc.) and if necessary install a prefilter. 

 
 

Pressure line connection 

 

The pressure line (should be at least 3/4") must be connected directly or via a thread nipple to the 
pressure line connector (1" internal thread) of the pump. 
With the suitable screw joints a 1/2"- pressure hose can be used. Correspondingly the pump 
output is reduced due to the small pressure hose. 

 

During the suction process the shut-off devices (valves, spray nozzles) in the pressure line must 
be completely open so that the air in the suction line can escape freely. 

 
Commissioning 

 

Position  the  pump  on  a  stable  and  flat  location  with  a  temperature  that  does  not  exceed  40°C. 
Place  the  pump  in  a  horizontal  position  so  that  the  bearing  can  function  properly;  tighten  the 
pump to the ground.  

 

Install  the  suction  line  so  that  it  is  ready  for  use.  The  suction  hose  should  not  be  narrower  than 
the  suction  connection.  If  the  suction  height  exceeds  4  m,  you  must  use  a  suction  line  with  a 
larger diameter. 

 

Establish the electrical connection. 

 

Fill in the pump with water at the pressure port. 

 

During the suction process the shut-off devices (valves, spray nozzles) in the pressure line must 
be completely open so that the air in the suction line can  escape freely. 

 

Depending on the suction height and the air quantity in the suction line, the first suction process 
can take approx. 0,5 min - 5 min. For longer suction periods new water should be refilled. 

 

If the pump is removed after its use, do not forget it has to be refilled with water (before you 
operate the pump again) before restarting and connecting it again.

Содержание 50752

Страница 1: ...operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ...es of water garden ponds or swimming ponds and their surrounding areas only with fault current protection switch with a triggering nominal current up to 30mA according to VDE 0100 Article 702 and 738 The device is not suitable for use in swimming pools paddling pools and other bodies of water in which during operation people or animals linger The operation of the device during the stay of people a...

Страница 3: ...ury Keep the instructions and the safety guidelines in a safe place in case you need them in the future Stability The max temperature of the conveyed water should not exceed 35 C in permanent operation The conveyance of explosive flammable or gassing fluids is not allowed The conveyance of aggressive fluids acids bases etc as well as of abrasive liquids for example sand must be avoided To avoid da...

Страница 4: ...uction of water due to air intake Avoid sucking in foreign particles sand etc and if necessary install a prefilter Pressure line connection The pressure line should be at least 3 4 must be connected directly or via a thread nipple to the pressure line connector 1 internal thread of the pump With the suitable screw joints a 1 2 pressure hose can be used Correspondingly the pump output is reduced du...

Страница 5: ...ocked connect the pressure line to the water line and remove the suction hose Open the water line Turn on the pump for sevaral times for approx two seconds This way blockages can be cleared in most cases Pump s Dysfunctions No engine running Cause Remedy No supply voltage Check the power supply Pump wheel is blocked Thermal controller has shut down Dismantle the pump and clean it Parts Description...

Страница 6: ...ion valve more deeply Pump efficiency is reduced due to harmful substances Clean the pump and replace the wear part Thermal controller shuts down the pump Cause Remedy Engine overload high friction with other foreign particles Dismantle the pump and clean it prevent the suction of foreign particles Filter Attention The pump must not run dry Pump control Pressure switch EDWC2001 The pressure switch...

Страница 7: ...e to lack of water protection against dry running press Restart to start the unit again 2 The middle 2nd LED blinks the pump is switched on 3 The lower 3rd LED blinks the switch has voltage 4 Restart Reset restart button Possible dysfunctions and their solutions Dysfunction Dysfunction of the unit Dysfunction outside the unit The pump won t start Circuit board is damaged Missing voltage Pump is de...

Страница 8: ...parate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment and he...

Страница 9: ...perly used the above mentioned model fulfils the basic requirements and the guidelines complying with the 2004 108 EC When evaluating the product according to the EU demands the following standards were applied EN 55014 1 2006 EN 55014 2 1997 A1 EN61000 3 2 2006 EN61000 3 3 1995 A1 A2 If the product is changed this declaration loses its validity Eschweiler 13 Oktober 2009 _________________________...

Отзывы: