WilTec 50752 Скачать руководство пользователя страница 3

  

© by WilTec Wildanger Technik GmbH  

 

Seite 3  

http://www.wiltec.info  

 

Before  working  on  the  garden  pump  disconnect  the  appliance  by  taking  the  plug  out  of  the 
socket. 

 

The  user  is  responsible  for  the  compliance  with  location  specific  safety  and  installing 
regulations. (Ask an electrician). 

 

Consequential  damage  arising  from  flooded  rooms  caused  by  dysfunctions  of  the  appliance 
must be avoided by means of 

the 

appropriate measures. (installing an alarm system, reserve 

pump). 

 

In case of malfunction the repair work can be carried out only by a qualified electrician or the 
WilTec-service. 

 

The  garden  pumps  must  not  run  dry  or  having  a  completely  closed  intake  port.  The 
manufacturer’s guarantee is no longer valid if the damage is caused by dry running. 

 

The garden pump must not be used for swimming pools. 

 

The device cannot be employed for potable water circuits. 

 

WARNING

 

Read carefully all the safety guidelines and the instructions.

  

Non-compliance with the safety rules and regulations can lead to an electric shock, fire and/or serious 
injury.  Keep  the  instructions  and  the  safety  guidelines  in  a  safe  place  in  case  you  need  them  in  the 
future. 
 

Stability 

The max. temperature of the  conveyed  water should  not exceed  +35°C  in permanent operation. The 
conveyance of explosive, flammable or gassing fluids is not allowed. 
The  conveyance  of  aggressive  fluids  (acids,  bases,  etc.)  as  well  as  of  abrasive  liquids  (for  example 
sand) must be avoided. 
To avoid damage caused by dry running we strongly recommend our customers to use one of our 
automatic pump controls that prevent the pump from running dry. 
 

Intended use 
 
Field of application 

 

For watering green spaces, vegetable patches and gardens. 

 

For operating lawn sprinklers. 

 

With  pre-filter  for  withdrawing  water  from  ponds,  streams,  rain  barrels,  rainwater  tanks  and 
fountains. 

 

Pumped media 

For pumping clear water (sweet water), rain water or suds (slightly soiled water). 
 
 

Operating instructions 

We recommend the use of a prefilter and a suction set with suction hose, suction strainer and a check 
valve to prolong the suction process and to avoid damaging the pump with stones and foreign bodies. 
 

Technical Data: 

 

Pump output  

1200 W 

Voltage/Frequency 

220V/50Hz 

Max. flow rate 

3500 l/h 

Max. delivery head 

46 m 

Max. suction head 

8 m 

Connection 

1“ IG 

  

 

Содержание 50752

Страница 1: ...operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ...es of water garden ponds or swimming ponds and their surrounding areas only with fault current protection switch with a triggering nominal current up to 30mA according to VDE 0100 Article 702 and 738 The device is not suitable for use in swimming pools paddling pools and other bodies of water in which during operation people or animals linger The operation of the device during the stay of people a...

Страница 3: ...ury Keep the instructions and the safety guidelines in a safe place in case you need them in the future Stability The max temperature of the conveyed water should not exceed 35 C in permanent operation The conveyance of explosive flammable or gassing fluids is not allowed The conveyance of aggressive fluids acids bases etc as well as of abrasive liquids for example sand must be avoided To avoid da...

Страница 4: ...uction of water due to air intake Avoid sucking in foreign particles sand etc and if necessary install a prefilter Pressure line connection The pressure line should be at least 3 4 must be connected directly or via a thread nipple to the pressure line connector 1 internal thread of the pump With the suitable screw joints a 1 2 pressure hose can be used Correspondingly the pump output is reduced du...

Страница 5: ...ocked connect the pressure line to the water line and remove the suction hose Open the water line Turn on the pump for sevaral times for approx two seconds This way blockages can be cleared in most cases Pump s Dysfunctions No engine running Cause Remedy No supply voltage Check the power supply Pump wheel is blocked Thermal controller has shut down Dismantle the pump and clean it Parts Description...

Страница 6: ...ion valve more deeply Pump efficiency is reduced due to harmful substances Clean the pump and replace the wear part Thermal controller shuts down the pump Cause Remedy Engine overload high friction with other foreign particles Dismantle the pump and clean it prevent the suction of foreign particles Filter Attention The pump must not run dry Pump control Pressure switch EDWC2001 The pressure switch...

Страница 7: ...e to lack of water protection against dry running press Restart to start the unit again 2 The middle 2nd LED blinks the pump is switched on 3 The lower 3rd LED blinks the switch has voltage 4 Restart Reset restart button Possible dysfunctions and their solutions Dysfunction Dysfunction of the unit Dysfunction outside the unit The pump won t start Circuit board is damaged Missing voltage Pump is de...

Страница 8: ...parate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment and he...

Страница 9: ...perly used the above mentioned model fulfils the basic requirements and the guidelines complying with the 2004 108 EC When evaluating the product according to the EU demands the following standards were applied EN 55014 1 2006 EN 55014 2 1997 A1 EN61000 3 2 2006 EN61000 3 3 1995 A1 A2 If the product is changed this declaration loses its validity Eschweiler 13 Oktober 2009 _________________________...

Отзывы: