6.1 G
ETTING STARTED
Operating steps:
1. Go to normal monitor state;
2. Press
PRESET
, then "Axis to Preset" appears in the message window, which means
that you are going to preset features value.
Description
The features that preset are temporary features.
6.2 P
RESETTING THE CURRENT COORDINATE POSITION
Function description:
Preset the data value according to current position when DRO is in normal monitor
state.
Example:
Preset 12.324 to the display value of current position of X-axis
Operating steps:
1. Return normal monitor state;
2. Press
PRESET
, then "Axis to Preset" appears in the message window, which means
that you just being to preset
3. Press
X0
;
4. Press
1 2 . 3 2 4 +/-
in turns ,the preset value will be -12.324;
5. Press
ENTER
to confirm the inputting value. Then the value -12.324 is displayed in
X window, which means that the operation is successfully.
Note:
(1)
User can press
CANCEL
to cancel the last preset value or press
QUIT
to cancel the preset operation .
(2) If you want to preset the current position of Y-axis or Q-axis, just press
Y0
or
Q0
in step 3.
6.3 P
RESETTING POINT FEATURE
Function description:
To get a point feature
Example:
Preset a point feature, its coordinate is (1.234, -5.678)
Operating steps:
1. Return normal monitor state;
2. Press
PRESET
, then "Axis to Preset" appears in the message window, which means
that you have entered the preset operation;
3. Press
POINT
, then "X 0.000" appears in the LED window;
4. Press
1
.
2 3 4
in turns to input X axis' value;
5. Press
ENTER,
then "Y 0.000" appears in the message window;
6. Press
5
.
6 7 8
and
+/-
in turns, input Y axis value;
7. Press
ENTER
to confirm the above operation, then "a0 point X/Y" appears in the
message window, 1.234 appears in the X window, -5.678 appears in the Y window,
which means that the preset operation is successfully.
32
Manual WDC-300
6. P
RESET FEATURE