Z 15+ - Timer Type Circulation Pump 

Version 21.07 

 

 

Please read over the operating manual prior to 

installation and keep it for reference. 

 

Step 2: Turn off the power to the water heater and isolate the cold-water supply to water heater; 
open the hot water tap in the house and wait until the residual water is drained out. 

Step 3: Install the water pump at the hot water outlet of water heater; connect the outlet of water 
pump to the hot water pipeline. Confirm the pumping direction through the arrow on the side of 
pump case, and the installed water pump shall be kept away from exhaust/gas lines. Make sure to 
insert the supplied gasket into the union end connection of the pump to ensure a leakproof seal. 

Step 4: Reopen the cold-water supply to the water heater and close the furthest faucet when the 
pipeline is filled with water to exhaust the air completely; power on the water heater and the water 
pump. 

Step 5 (applies to models with timer only): Set the timing function of water pump to make it operate 
in the peak period of hot water use. (e.g., 15-30min before taking a shower) 

Step 6: Close the cold and hot water angle valves below the tap, and observe the signs of cold water 
inlet/outlet and hot water inlet/outlet of the temperature-sensing bypass valve; use braided hoses 
to connect the cold water angle valve and the “COLD IN” of valve, connect the hot water angle valve 
and the “HOT IN” of the valve, connect the “COLD OUT” of the valve and the cold water end of the 
tap, and connect the “HOT OUT” of the valve and the hot water end of the tap; open the hot water 
angle valve and the cold water tap to check whether the valve operates normally (if the water runs 
out from the cold water tap normally and becomes warm, and the water flow becomes small slowly 
until it stops, it indicates that the valve operates normally); close the tap and open the cold water 
angle valve. 

Note: 1. To obtain the best circulating results, the valve shall be installed below the tap the farthest 
away from the water heater; if there are branch hot water pipes in your house, more than one valve 
may be needed. 2. There may be some warm water in the cold water pipeline connected with the 
valve, and warm water will dissipate soon when the cold water tap is opened. 

Outline dimensions of the product* 

 

 

*Pump pictured with timer 

Содержание Z 15+

Страница 1: ...Installation and Operating Instructions Wilo Z 15 Timed and Constant Temperature Circulating Pump WILO_IOM_Z15 _0821...

Страница 2: ...on and keep it for reference The main electrical connection to the pump must be grounded before use It is strictly prohibited to touch the electrical connections of the pump while the pump is in opera...

Страница 3: ...RIPTION 1 II TECHNICAL PARAMETERS 2 III INSTALLATION PRECAUTIONS 2 IV HOW TO USE applies to models with timer only models without timer skip to SECTION V FAULT ANALYSIS AND ELIMINATION 4 V FAULT ANALY...

Страница 4: ...prohibited for children to use the product unless they are under the supervision of an adult Warning about pressure The system pressure must be less than the maximum pump pressure to operate properly...

Страница 5: ...the water must be greater than 32 F and the maximum temperature is 160 F 2 The inlet supply pressure must be higher than 75 PSI to work properly III INSTALLATION PRECAUTIONS For best performance and r...

Страница 6: ...5 30min before taking a shower Step 6 Close the cold and hot water angle valves below the tap and observe the signs of cold water inlet outlet and hot water inlet outlet of the temperature sensing byp...

Страница 7: ...f time is 1 hour in the timing function Screen function applies to models with timer only From 9 00 p m to 7 00 a m the display interface of water pump will enter the screen rest mode if not operated...

Страница 8: ...me calibration function by pressing the Run key or not operating for 20s Timing function Set the running period of water pump press the Timing key the dial indicator lamp becomes flashing and press th...

Страница 9: ...he jet valve Open the angle valve The non return function of the jet valve has failed Replace the jet valve The pump does not run The current set time is not turned on Turn on the current set time The...

Отзывы: