Z 15+ - Timer Type Circulation Pump 

Version 21.07 

Please read over the operating manual prior to 

installation and keep it for reference. 

Thank you for choosing the WILO® Z 15+ domestic hot water recirculator pump.    Please read over 
the operating manual prior to installation and keep it for reference. 

Warning 

 

The pump must 

be electrically grounded

 before use.

 

It is strictly prohibited to touch the electric components of the pump while powered and in

operation.

 

It is strictly prohibited to run the pump without water.

Warning about children

 

It is strictly prohibited for children to use the product unless they are under the supervision of

an adult.

Warning about pressure

 

The system pressure must be less than the maximum pump pressure to operate properly.

Warning about modifying the pump without manufacturer’s knowledge

 

The manufacturer bears no liability for any consequences caused by the user’s unauthorized

changes  to the  electrical schematic of the  pump or physical changes beyond its original

construction or design.

I. MODEL DESCRIPTION

Z 15 + WITH TIMER .75 - 9 - 5.5 

Maximum flow in US Gallons per Minute 
Maximum Head in Feet 
Size of pump inlet and outlet in inches 
Pump Model: Z 15+ WITH TIMER OR 

 Z 15+ WITHOUT TIMER   

Please read over the operating manual prior to 

installation and keep it for reference. 

Содержание Z 15+

Страница 1: ...Installation and Operating Instructions Wilo Z 15 Timed and Constant Temperature Circulating Pump WILO_IOM_Z15 _0821...

Страница 2: ...on and keep it for reference The main electrical connection to the pump must be grounded before use It is strictly prohibited to touch the electrical connections of the pump while the pump is in opera...

Страница 3: ...RIPTION 1 II TECHNICAL PARAMETERS 2 III INSTALLATION PRECAUTIONS 2 IV HOW TO USE applies to models with timer only models without timer skip to SECTION V FAULT ANALYSIS AND ELIMINATION 4 V FAULT ANALY...

Страница 4: ...prohibited for children to use the product unless they are under the supervision of an adult Warning about pressure The system pressure must be less than the maximum pump pressure to operate properly...

Страница 5: ...the water must be greater than 32 F and the maximum temperature is 160 F 2 The inlet supply pressure must be higher than 75 PSI to work properly III INSTALLATION PRECAUTIONS For best performance and r...

Страница 6: ...5 30min before taking a shower Step 6 Close the cold and hot water angle valves below the tap and observe the signs of cold water inlet outlet and hot water inlet outlet of the temperature sensing byp...

Страница 7: ...f time is 1 hour in the timing function Screen function applies to models with timer only From 9 00 p m to 7 00 a m the display interface of water pump will enter the screen rest mode if not operated...

Страница 8: ...me calibration function by pressing the Run key or not operating for 20s Timing function Set the running period of water pump press the Timing key the dial indicator lamp becomes flashing and press th...

Страница 9: ...he jet valve Open the angle valve The non return function of the jet valve has failed Replace the jet valve The pump does not run The current set time is not turned on Turn on the current set time The...

Отзывы: