TRANSPORT AND STORAGE
•
If the product is to be used with highly flammable, explosive and/or aggressive fluids,
the manufacturer must be consulted.
2.7.
Sound pressure
The product itself is generally operated under water and only with air. This means that
the sound pressure cannot be measured.
However, the air is supplied using a compressor. Depending on its power and environ
-
mental conditions, this compressor can have elevated sound pressure.
For this reason we recommend that the operator carry out an the additional measure
-
ment in the workplace when the product is operating.
CAUTIon: Wear ear protectors!
In terms of the applicable laws and regulations, ear protection must be worn if the
sound pressure is greater than 85 dB (A). The owner is responsible for ensuring
compliance with these regulations.
3.
Transport and storage
3.1.
Delivery
On delivery, immediately check that the product is complete and undamaged. If any
parts are damaged or missing, the transport company or the manufacturer must be no
-
tified on the day of delivery. Claims made after this date cannot be recognized. Damage
to parts must be noted on the delivery or freight documentation.
3.2.
Transport
Before transport, the product must be packaged in such a way that it is protected from
moisture, frost and other damage. It is important to keep the original packaging.
3.3.
Storage
•
The components must be stored in the original packaging.
•
The store room must be dry and frost-proof. We recommend storage in a room with a
temperature between 10 °C and 25 °C. The temperature may not 50 °C.
•
The product must be protected from direct sunlight, heat, dust and frost. Furthermore,
the product may not be stored in rooms where welding takes place. Heat and cold, as
well as the gas and radiation given off during welding, can damage the plastic parts.
•
New disc aerators may not be stored for more than three months. If they are stored for
more than three months, there is a risk that the membranes will become porous and
leaky.
Содержание Wilo-Sevio AIR
Страница 2: ...Fig 1 1 3 2 5 6 9 7 8 10 4 2 ...
Страница 3: ...Fig 2 Fig 3 1 3 2 5 6 7 8 4 1 3 2 2 4 ...
Страница 4: ...Fig 5 Fig 4 1 3 2 5 5 6 6 7 8 4 1 3 2 5 6 7 8 4 ...
Страница 5: ...Fig 6 Fig 7 1 3 2 5 5 5 4 1 3 3 2 2 ...
Страница 6: ...Fig 8 Fig 9 Fig 10 1 4 3 5 2 2 1 3 1 ...
Страница 7: ...Fig 11 Fig 12 1 Fig 12 2 5 1 min 800 mm 10 cm ...
Страница 8: ...Fig 12 3 10 cm ...