ENGLISH
12
8 Fault finding- Causes and Remedies
If the faults cannot be located and rectified, please contact your nearest Wilo representative.
Technical modifications reserved!
Fault
Cause
Remedy
Pump does not fill
Air entry in suction pipe
Check condition of pipe, connections,
and seals.
Cover of lint strainer does
Clean strainer cover and check condition
not seal tight
of O-ring washer.
Wrong direction of motor
Change any two phase wires.
rotation (3-phase motor)
Insufficient pump
Air entry in suction pipe
Check condition of pipe , connections,
performance
and seals.
Wrong direction of motor
Change any two phase wires.
rotation (3-phase motor)
Pressure loss in suction
Eliminate any element causing excessive
pipe
resistance.
Wrong voltage
Check that available voltage corresponds
with name plate data.
Chocked lint strainer
Clean lint strainer
Chocked main sand filter
Start backwash cycle.
Motor failure
Loss of phase
The original operating conditions are
automatically restored on power restoration.
WSK of pump motor has
Let motor cool down, reset fault at switchbox,
tripped
pump will restart. On repeated tripping of the
WSK it will be necessary to check pump
electrically and mechanically.
Содержание Wilo-FilTec FBS
Страница 2: ...Fig 1 Fig 2 Fig 2a...
Страница 3: ...Fig 5 Fig 4 Fig 3...