Safety
en
Installation and operating instructions Wilo-EMU TR/TRE 212 ... 326-3
9
ƒ
Disinfect product.
2.8
During operation
ƒ
Wear protective equipment according to work regulations.
ƒ
Demarcate and cordon off the working area.
ƒ
No persons are allowed in the working area during operation.
ƒ
Depending on the process, the product is activated and deactivated using separate
controls. Product may automatically activate following power cuts.
ƒ
If the motor emerges, the motor housing can heat up to above 40 °C (104 °F).
ƒ
Superior must be informed immediately of any faults or irregularities.
ƒ
Operator must switch product off immediately if faults occur.
ƒ
Propeller must not crash into fixtures or walls. Observe defined clearances in accord-
ance with consulting documents.
ƒ
Observe required water immersion. If water level varies significantly, use level mon-
itoring.
ƒ
Sound-pressure level depends on several factors (installation, duty point, etc.). If the
product is operated under normal operating conditions, the operator must measure
the sound pressure. From a sound-pressure level of 85 dB(A) upward, wear hearing
protection and mark the working area!
2.9
Maintenance tasks
ƒ
Wear the following protective equipment:
–
Sealed safety goggles
–
Safety gloves for protection against cuts
–
Safety footwear
ƒ
Disconnect device from the mains and secure it against being switched on again
without authorisation.
ƒ
Carry out maintenance work in a clean, dry and well-lit place.
ƒ
Only carry out maintenance tasks described in these installation and operating in-
structions.
ƒ
Only original parts of the manufacturer may be used. The use of any non-original
parts releases the manufacturer from any liability.
ƒ
Collect any leakage of fluid and operating fluid immediately and dispose of it ac-
cording to the locally applicable guidelines.
ƒ
Disinfect product.
Changing operating fluid
In the event of a motor defect, pressure of
several bar can build up
in the sealing
chamber! This pressure is released when the screw plugs are
opened
. If screw plugs are
opened without due caution, they can be ejected at high speed! To avoid injuries, ob-
serve the following instructions:
ƒ
Adhere to the prescribed sequence of work steps.
ƒ
Unscrew the screw plugs slowly, but never unscrew them completely. As soon as
pressure is released (audible whistling or hissing of air), stop turning the screw plug
any further.
WARNING! Hot operating fluids can also spray out when pressure is released. This
can result in scalding! To avoid injuries, allow the motor to cool down to the am-
bient temperature before carrying out any work!
ƒ
When the pressure has been completely released, fully unscrew the screw plug.
2.10
Operating fluid
The product uses the following operating fluids:
ƒ
The seal housing is filled with white oil.
ƒ
The gear and the pre-chamber are filled with gear oil.
Replace the operating fluids during regular maintenance work and dispose of them ac-
cording to the local guidelines.
2.11
Operator responsibilities
ƒ
Provide installation and operating instructions in a language which the personnel can
understand.
ƒ
Make sure that the personnel have received the required training for the specified
work.
ƒ
Provide protective equipment. Ensure that the protective equipment is worn by per-
sonnel.
ƒ
Ensure that safety and information signs mounted on the device are always legible.
ƒ
Train the personnel on how the system operates.
ƒ
Eliminate any risk from electrical current.
ƒ
Fit dangerous components within the system with an on-site guard.
ƒ
Demarcate and cordon off the working area.